Add condensed C&G version, venue survey, loss rationale; declare bank-size ablation
- paper_cg/: self-contained condensed article in the Elsevier CAS template (17 pages) and a supplement that inputs paper/sections/ (S-prefixed numbers); Elsevier CAS bundle v2.4 vendored for the build; make_submission.sh. - paper/sections: American spelling, "Why a Gaussian likelihood" paragraph (Sec. 4) and a "Loss family" limitation; nix1994meanvariance added. - docs: venue survey (submission venue Geophysical Prospecting, fallback Mathematical Geosciences), loss-ablation plan (dropped, kept as a record), lecture rewritten to 12/11, plan/AGENTS/report synced (plan items 47-54). - Bank-size ablation (exploratory): declaration docs/research/bank-size.md hashed before any computation (1a192127...), scripts/49_bank_size.py. The run is in progress; no results are included in this commit. No verdict, threshold or locked protocol changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -56,7 +56,7 @@ Ceiling & Oracle & 0.612 & 0.451 & 0.897 & 0.948 \\
|
||||
At $N = 4$ all four anchor-free losses were worse than the calibrated sonic, the tie whose labels they start from. Hard-min and soft-min shift banks were 38--53\% worse than it at both $N$. At $N = 16$, soft-DTW and DILATE were 4--6\% better than the calibrated sonic but still far behind the correlation tie and the reweighted anchor bank. This is consistent with Proposition~\ref{prop:ident}, which does not predict the sign of the change: within the shift range, the loss cannot tell a better alignment from a jointly shifted network and label.
|
||||
|
||||
\paragraph{Anchors are necessary.}
|
||||
At $c = 1$, $N = 4$ we removed the anchors from both anchor banks and kept only the warp prior ($\sigma_b = 50$\,ms) and, for the reweighted bank, the tie likelihood. To favour the anchor-free variant, it was given the true (zero) wavelet phase. Warp RMSE rose from 3.15 to 31.1\,ms for the reweighted bank (ratio 9.9, 95\% CI [8.3, 11.4]) and from 3.71 to 33.0\,ms for the unweighted bank. Band RMSE rose from 0.735 to 1.398\,p.u.\ (ratio 1.90, CI [1.80, 2.04]) and from 0.805 to 1.594\,p.u. The size of the warp error is consistent with Proposition~\ref{prop:ident}: with $\sigma_b = 50$\,ms and $N = 4$, $\sd(\beta) \approx 25$\,ms.
|
||||
At $c = 1$, $N = 4$ we removed the anchors from both anchor banks and kept only the warp prior ($\sigma_b = 50$\,ms) and, for the reweighted bank, the tie likelihood. To favor the anchor-free variant, it was given the true (zero) wavelet phase. Warp RMSE rose from 3.15 to 31.1\,ms for the reweighted bank (ratio 9.9, 95\% CI [8.3, 11.4]) and from 3.71 to 33.0\,ms for the unweighted bank. Band RMSE rose from 0.735 to 1.398\,p.u.\ (ratio 1.90, CI [1.80, 2.04]) and from 0.805 to 1.594\,p.u. The size of the warp error is consistent with Proposition~\ref{prop:ident}: with $\sigma_b = 50$\,ms and $N = 4$, $\sd(\beta) \approx 25$\,ms.
|
||||
|
||||
\paragraph{The bank was not better calibrated.}
|
||||
The hash-locked hypothesis that bank ensembles are better calibrated than the calibrated-sonic ensemble was rejected. Pooled over $N$ at $c = 1$, the calibration error was 0.278 for the reweighted bank against 0.230 for that ensemble (difference 0.048, 95\% CI [0.035, 0.061]). Every ensemble under-covered.
|
||||
@@ -174,7 +174,7 @@ At $c = 1$, $N = 16$, the 90\% coverage of the SMC warp posterior was 0.89 at 10
|
||||
\begin{figure}[t]
|
||||
\centering
|
||||
\includegraphics[width=\linewidth]{p2r_grid.pdf}
|
||||
\caption{Experiment 2 overview. Band RMSE of each method divided by that of the Oracle (true warp), by observation setting and drift factor $c$, for (a) $N = 4$ and (b) $N = 16$ training wells. Each entry is the mean over 8 realizations $\times$ 5 seeds. The colour scale is clipped at 2.0; the two-anchor setting at $c = 2$ reaches 3.15.}
|
||||
\caption{Experiment 2 overview. Band RMSE of each method divided by that of the Oracle (true warp), by observation setting and drift factor $c$, for (a) $N = 4$ and (b) $N = 16$ training wells. Each entry is the mean over 8 realizations $\times$ 5 seeds. The color scale is clipped at 2.0; the two-anchor setting at $c = 2$ reaches 3.15.}
|
||||
\label{fig:p2rgrid}
|
||||
\end{figure}
|
||||
|
||||
@@ -409,7 +409,7 @@ $-5$\,dB, $N = 16$ & Phase-est.\ corr. & 0.89 & 0.92 & 0.08 & 0.51 & 0.31 & 11
|
||||
\label{sec:exp:scope}
|
||||
|
||||
\paragraph{Neither field test met its pass rule.}
|
||||
On F3, with four wells, the rule required the \mRML{} to have a lower band RMSE than the selected deterministic tie at no fewer than three of the four blind wells, and macro coverage of its 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$. On Volve, with six deviated wells and a density-driven porosity label, the (descriptive) rule asked for the same at five of six wells under two hold-out schemes (single wells, and slots, the groups of wells that share a borehole), with total RMSE on the labelled samples. On F3, the \mRML{} improved at one well of four, and coverage was 0.52 and 0.61. On F3 no learned model beat a depth--time trend in total RMSE (Appendix~\ref{app:field}). Its sensitivity variants (anchor uncertainty, scoring reference, band split, label) improved at one to three wells and never met the coverage condition. On Volve, it improved at two (leave-one-well-out) and three (slot) of six wells, and coverage of the 90\% interval was 0.48 and 0.47. No method had skill at the Volve blind wells: macro $R^2$ was negative for every method, and a constant at the training-well mean of the porosity label (PHIF) had a lower macro RMSE than every network (6.03 and 6.59\,p.u.\ under the two schemes, against 6.50 and 7.13\,p.u.\ for the \mRML; post hoc). We claim no improvement on field data and no calibrated uncertainty. At F-11 T2, the one Volve well with a VSP, changing the scoring reference moved the RMSE of each method by more than the spread between methods and reordered them (post hoc). Appendix~\ref{app:field} gives the designs and all tables.
|
||||
On F3, with four wells, the rule required the \mRML{} to have a lower band RMSE than the selected deterministic tie at no fewer than three of the four blind wells, and macro coverage of its 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$. On Volve, with six deviated wells and a density-driven porosity label, the (descriptive) rule asked for the same at five of six wells under two hold-out schemes (single wells, and slots, the groups of wells that share a borehole), with total RMSE on the labeled samples. On F3, the \mRML{} improved at one well of four, and coverage was 0.52 and 0.61. On F3 no learned model beat a depth--time trend in total RMSE (Appendix~\ref{app:field}). Its sensitivity variants (anchor uncertainty, scoring reference, band split, label) improved at one to three wells and never met the coverage condition. On Volve, it improved at two (leave-one-well-out) and three (slot) of six wells, and coverage of the 90\% interval was 0.48 and 0.47. No method had skill at the Volve blind wells: macro $R^2$ was negative for every method, and a constant at the training-well mean of the porosity label (PHIF) had a lower macro RMSE than every network (6.03 and 6.59\,p.u.\ under the two schemes, against 6.50 and 7.13\,p.u.\ for the \mRML; post hoc). We claim no improvement on field data and no calibrated uncertainty. At F-11 T2, the one Volve well with a VSP, changing the scoring reference moved the RMSE of each method by more than the spread between methods and reordered them (post hoc). Appendix~\ref{app:field} gives the designs and all tables.
|
||||
|
||||
\paragraph{Neither test could have detected the effect.}
|
||||
After both tests had failed, we stated four conditions under which a field test of this kind bears on the synthetic result and evaluated them without test labels. Their thresholds come mechanically from Experiment~2, so the conditions are post hoc but were not tuned to the field results.
|
||||
|
||||
Reference in New Issue
Block a user