Complete P4 Volve; pivot the manuscript to theory + benchmark

P4 (Volve field case). Add the deviated-well and Volve well builders
(ml_porosity/data/deviated.py, volve_wells.py), the ml_porosity/volve/
pipeline, scripts 23-25, the run_p4 drivers and tests. The protocol
configs/protocol_volve.yaml was locked at 2026-10-29T01:17:42Z before the
run (.sha256, .lock.json) and is committed here after the run. Gate G-D
failed: M2-Sa beats the selected B3 at 2/6 wells (lowo) and 3/6 (slot),
coverage90 is about 0.47, and no method has blind-well skill (R2 < 0).
A post hoc constant at the training-well mean beats every network, so
G-D had no power. The dropped P4x exploratory run is kept as a record
only (exploratory/, docs/research/p4-exploratory.md).

Applicability and Teapot Dome (exploratory, pre-declared). Scripts 26-29
and docs/research/applicability-*.md: F3 and Volve fail C1 and pass C2;
T3 power needs 5-18 blind wells with an exact reference; Teapot T0 and
pilot P-a failed, so Teapot is stopped. Raw Teapot data stay gitignored.

Manuscript (Pivot 1, level A). Reframe paper/ as a theory and synthetic
benchmark paper: Propositions 3-6, Corollaries 3-4, T4 coverage
(script 30) and the post hoc H2b bound check (script 31), with F3/Volve
moved to Appendix B. Correct two earlier claims: the Berkson and
classical bounds differ by 1.5-4.6x at the f^4-weighted band, and the
bank gain exceeds the registered classical bound (7/8 wide cells at
N = 16) but only 3/8 under the post hoc Berkson bound.

Docs. Sync plan, AGENTS.md, README, report.html, theory and technical
overview. The length pass for the venue is dropped by the user
(plan section 12 item 25); the length risk stays recorded as R9.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-29 12:18:22 +00:00
parent 7da6b077b6
commit 0cfe202a8b
61 changed files with 7162 additions and 881 deletions

View File

@@ -57,7 +57,16 @@ The true time--depth warp of each well is drawn from the warp prior of Section~\
\end{itemize}
Under the F3 warp prior, Rm5 gives the posterior width closest to F3 (Section~\ref{sec:exp:p2r}).
\subsection{Second field dataset}
\subsection{Volve field}
\label{sec:data:volve}
\todoblock{Volve (Equinor; licence CC BY-NC-SA 4.0): wells, logs, target window, time--depth data, and the porosity definition (independent of sonic where possible). Gate G-D; pipeline 28/10, runs 29/10. If Volve is cut (plan \S6 cut order), remove this subsection and the corresponding claims.}
The second field dataset is Volve (Norwegian North Sea), released by Equinor under a CC BY-NC-SA 4.0 licence \todo{dataset citation (Equinor Volve data village)}. Its role is to break the label structure of F3. The computed effective porosity PHIF of the operator's petrophysical interpretation is driven by density, not by sonic: within each well its correlation with RHOB is $-0.92$ to $-0.99$, RHOB and NPHI explain 84--98\% of its variance, and adding DT raises this by at most 0.9 percentage points. Six wells have DT, RHOB, NPHI and PHIF: F-1, F-1 A, F-1 B, F-11 A, F-11 T2 and F-12. All six are deviated (maximum inclination 30--82$^\circ$; 4--54$^\circ$ over the labelled interval), and they share one platform. F-1 A and F-1 B leave the F-1 borehole at 2587\,m MD, and F-11 A leaves F-11 T2 at about 2580\,m MD, so the wells form three slot groups, \{F-1, F-1 A, F-1 B\}, \{F-11 A, F-11 T2\} and \{F-12\}, whose members share the hole above the kick-off.
\paragraph{Seismic and geometry.}
We use the post-stack ST10010 full-angle stack (3--41$^\circ$), a 2011 depth migration converted to time, at 4\,ms sampling. Its trace headers carry an invalid time scalar that standard readers apply to the start time, which shifts every sample 8\,ms late. We use the start time of the text header (4\,ms) and checked it against five interpreted horizons: the amplitude extremum along each falls at a lag of 0 to $+2$\,ms. Trajectories come from the operator's definitive surveys; recomputing them by minimum curvature reproduces the listed TVD within 0.01\,m. The seismic input of a well is a $3\times3$ patch of traces interpolated bilinearly along the deviated path at the time given by its time--depth relation, because a vertical trace at one bin differs from the path composite by a relative RMS of 0.19--0.61 over the labelled interval. Learning uses the window 2400--2900\,ms (126 samples) and tie likelihoods the extended window 2000--3200\,ms.
\paragraph{Time--depth and anchors.}
Only F-11 T2 has a zero-offset VSP. As anchors we use the operator's well picks with a TWT from the Ty Formation downwards, excluding picks flagged as not logged, not reached or faulted; each well has 4--9 such anchors within its logged sonic interval. Shallower picks are unreliable (picks at the same depth in a shared borehole differ by about 110\,ms). At reservoir level every unflagged pick lies within $\pm 10$\,ms of the corresponding interpreted horizon, and at F-11 T2 the picks lie within $-6.1$ to $+2.3$\,ms of the VSP. The pick times come from the operator's time--depth models, so they are interpretations, not measurements, as on F3. Time is vertical time: DT is integrated over TVD and calibrated to the anchors by stretching between them. At F-11 T2 this marker-calibrated sonic lies within $-2.4$ to $-0.8$\,ms of the VSP over the labelled interval. We keep $\sigma_a = 7$\,ms from F3; it is not estimated on Volve.
\paragraph{Labels.}
PHIF is used only where DT is valid, which leaves 16--37 labelled 4\,ms samples per well (150 in total) at 2509--2819\,ms. The labelled runs lie 25--179\,m below the deepest anchor, so their timing depends on the drift of the sonic below it. They are shorter than one period at 6\,Hz, so the band split used on F3 is undefined here. The well means of PHIF range from 8.5\,p.u.\ at F-1 to 17.0\,p.u.\ at F-12, against standard deviations of 3.3--6.0\,p.u.\ within wells.