Complete P4 Volve; pivot the manuscript to theory + benchmark

P4 (Volve field case). Add the deviated-well and Volve well builders
(ml_porosity/data/deviated.py, volve_wells.py), the ml_porosity/volve/
pipeline, scripts 23-25, the run_p4 drivers and tests. The protocol
configs/protocol_volve.yaml was locked at 2026-10-29T01:17:42Z before the
run (.sha256, .lock.json) and is committed here after the run. Gate G-D
failed: M2-Sa beats the selected B3 at 2/6 wells (lowo) and 3/6 (slot),
coverage90 is about 0.47, and no method has blind-well skill (R2 < 0).
A post hoc constant at the training-well mean beats every network, so
G-D had no power. The dropped P4x exploratory run is kept as a record
only (exploratory/, docs/research/p4-exploratory.md).

Applicability and Teapot Dome (exploratory, pre-declared). Scripts 26-29
and docs/research/applicability-*.md: F3 and Volve fail C1 and pass C2;
T3 power needs 5-18 blind wells with an exact reference; Teapot T0 and
pilot P-a failed, so Teapot is stopped. Raw Teapot data stay gitignored.

Manuscript (Pivot 1, level A). Reframe paper/ as a theory and synthetic
benchmark paper: Propositions 3-6, Corollaries 3-4, T4 coverage
(script 30) and the post hoc H2b bound check (script 31), with F3/Volve
moved to Appendix B. Correct two earlier claims: the Berkson and
classical bounds differ by 1.5-4.6x at the f^4-weighted band, and the
bank gain exceeds the registered classical bound (7/8 wide cells at
N = 16) but only 3/8 under the post hoc Berkson bound.

Docs. Sync plan, AGENTS.md, README, report.html, theory and technical
overview. The length pass for the venue is dropped by the user
(plan section 12 item 25); the length risk stays recorded as R9.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-29 12:18:22 +00:00
parent 7da6b077b6
commit 0cfe202a8b
61 changed files with 7162 additions and 881 deletions

View File

@@ -1,7 +1,7 @@
\section{Experiments}
\label{sec:experiments}
We ran two pre-registered synthetic experiments, in order, and then a pre-registered field test on F3 (Section~\ref{sec:exp:f3}). Before each main run, the protocol (grid, methods, iteration budgets, pass rules) was locked by a SHA-256 hash, and the scripts refuse to run if the hash does not match. The two synthetic protocols were also committed and tagged in version control before their main runs; the F3 protocol was committed and tagged only after its run (Section~\ref{sec:exp:f3}). In the synthetic experiments, every design choice was made on two development realizations (900 and 901), which are never used for results. Test labels were never used to choose a shift, checkpoint or hyperparameter. In the synthetic experiments, a comparison \emph{improves} if the candidate's seismic-band RMSE is at most 0.90 times that of the best competitor, \emph{or} its band PCC is at least 0.05 higher. Here ``best'' means the competitor with the smallest mean band RMSE in that cell. A cell \emph{passes} if the comparison improves in at least 4 of 5 seeds (each averaged over realizations) and in more than half of the realizations (each averaged over seeds). All cells use eight test wells.
We ran two pre-registered synthetic experiments, in order, and then pre-registered field tests on F3 and Volve (Section~\ref{sec:exp:scope}; details in Appendix~\ref{app:field}). Before each main run, the protocol (grid, methods, iteration budgets, pass rules) was locked by a SHA-256 hash, and the scripts refuse to run if the hash does not match. The two synthetic protocols were also committed and tagged in version control before their main runs. The field protocols were committed only after their runs, so for them the record of timing is the time stamp inside the lock file (Appendix~\ref{app:field}). In the synthetic experiments, every design choice was made on two development realizations (900 and 901), which are never used for results. Test labels were never used to choose a shift, checkpoint or hyperparameter. In the synthetic experiments, a comparison \emph{improves} if the candidate's seismic-band RMSE is at most 0.90 times that of the best competitor, \emph{or} its band PCC is at least 0.05 higher. Here ``best'' means the competitor with the smallest mean band RMSE in that cell. A cell \emph{passes} if the comparison improves in at least 4 of 5 seeds (each averaged over realizations) and in more than half of the realizations (each averaged over seeds). All cells use eight test wells.
\subsection{Experiment 1: anchor-posterior banks (gate G-B)}
\label{sec:exp:p2}
@@ -121,25 +121,34 @@ $\sigma_a^{\mathrm{reg}}$ (ms) & ratio $N = 4$ & ratio $N = 16$ & cells pass & $
\paragraph{H2b: RML helps when the posterior is wide.}
At $N = 16$ all three tests passed (Table~\ref{tab:h2b}, Fig.~\ref{fig:h2b}a). All 8 wide cells passed, the ratio decreased with $\sigpost$ (Spearman $\rho = -0.85$, one-sided permutation $p < 0.001$), and the mean ratio over narrow cells was 0.996. The gains in wide cells ranged from 2\% (Rm5, $c = 1$) to 11\% (R10tb, $c = 1$). At $c = 2$ they reached 33\% (R10tb), but those cells are flagged unstable. At $N = 4$, which was reported but not used for the verdict, 6 of 8 wide cells passed ($\rho = -0.77$, narrow mean 1.001).
The mechanism is not settled. In 7 of the 8 wide cells, the measured ratio is below $1/B(\sigpost)$ (Fig.~\ref{fig:h2b}b), the ratio that complete removal of Gaussian blur would give (Section~\ref{sec:theory:post}). At Rm5, $c = 1$, for example, the bound allows no gain (1.000), yet RML gained 2\%. Only in R10tb at $c = 2$ does the ratio (0.667) lie within the bound (0.634). Most of the gain therefore does not come from deblurring in the sense of Proposition~\ref{prop:blur}. We see two candidate explanations, which our experiments do not separate. One is label augmentation: the bank prevents the network from memorizing a single misregistered label. The other is that the posterior mean is biased when the posterior is multimodal.
\paragraph{Comparison with the population bound.}
The column $1/B_a$ of Table~\ref{tab:h2b} is the registered bound: $\rho^\star$ of \eqref{eq:rhostar} for Gaussian classical error at $\sigpost$, computed by blurring the Oracle's predictions. It is the largest gain over the point label that removing a population blur could give (Section~\ref{sec:theory:post}). The measured ratio is below it in 7 of the 8 wide cells (Fig.~\ref{fig:h2b}b). At Rm5, $c = 1$, for example, the bound allows no gain (1.000), yet RML gained 2\%. The exception is R10tb at $c = 2$, where $\sigpost$ lies beyond the 6\,ms edge of the grid on which $B$ was computed. The tabulated value is therefore $1/B_a(6\,\mathrm{ms})$, and at $\sigpost$ itself the bound is 0.481.
The registered structure is not the one expected for \mPM{}, whose labels sit at the posterior-mean warp. The natural idealization for the error of a posterior mean is the Berkson structure (b), and under (b) the bound is lower (Section~\ref{sec:theory:post}). The column $1/B_b$ gives this bound, computed post hoc in the same way but by sharpening the Oracle's predictions, at $\sigpost$ itself. The measured ratio is below it in 3 of the 8 wide cells, all at $c = 1$ (R0, R0h and R10tb). In R0h and R10tb the margin is less than 0.004, well inside the 95\% interval of the ratio. Sharpening also amplifies the Oracle's own estimation error, which lowers $1/B_b$, most of all at $c = 2$. Two variants limit this amplification. One holds the gain at its 60\,Hz value above 60\,Hz. The other replaces the spectrum of the Oracle's predictions by their cross-spectrum with the true labels. Both select the same three cells, and with the cross-spectrum the (a) bound is exceeded in only 5 of the 8 cells.
Both bounds are evaluated at the posterior width, which understates the error of an overconfident posterior. Evaluated instead at the measured warp error of \mPM{} on the training wells, the ratio is still below the (a) bound in 6 of the 8 cells but below the (b) bound in at most one (R0, $c = 1$, under the two variants). An excess over the population bound is therefore not established. It appears under the classical structure, and under the Berkson structure it is confined to $c = 1$ and mostly disappears at the measured warp error. Whether the error of the mean warp has the Berkson structure was not tested (Section~\ref{sec:exp:mech}).
The Oracle's advantage over \mPM{} can be compared with the same bounds. These ratios are post hoc and computed from the registered band RMSE of every method. At $c = 1$, $N = 16$, the Oracle's band RMSE was 0.93, 0.92 and 0.93 times that of \mPM{} at R0, R0h and Rm5, and 0.76 times at R10tb. These ratios are below the (a) bound in all four cells, below the (b) bound at $\sigpost$ in three or four of them, depending on the estimator, and below the (b) bound at the measured warp error in one or two. Part of the gap is not caused by registration at all. At $c = 0$, where the SMC warp RMSE on the training wells was 0.2--0.7\,ms and every bound is within 0.4\% of 1, the Oracle was still 1--3\% better than \mPM{} at $N = 16$. The two also differ in training length, which was selected on development data (500 and 250 iterations; Section~\ref{sec:method:train}).
In the wide cells at $N = 16$, \mRML{} closed 27--46\% of the gap between \mPM{} and the Oracle at $c = 1$, and 39--65\% at $c = 2$. It never reached the Oracle. Its band RMSE stayed 4--6\% above the Oracle's at R0, R0h and Rm5, and 17\% ($c = 1$) and 63\% ($c = 2$) above it at R10tb. The confirmatory experiments do not show where the gain comes from. If the error of the mean warp has the Berkson structure, most of the gain is within what removing the population sharpening of \mPM{} could give. A bank can also gain in finite samples. It acts as label augmentation: the network cannot memorize a single misregistered label, and the learned variance absorbs the spread of the bank and down-weights samples where the members disagree. For $\lambda > 0$ the responsibilities re-register the labels during training (Remark~\ref{rem:lambda}). When the posterior is multimodal, the error of the mean warp is not Gaussian, and the gain available to a bank can exceed the Gaussian bound (Corollary~\ref{cor:twomode}). Section~\ref{sec:exp:mech} examines these sources in an exploratory analysis.
\begin{table}[t]
\centering
\caption{H2b at $N = 16$, wide cells ($\sigpost \ge 1.5$\,ms): band RMSE of \mRML{} divided by that of \mPM{} (95\% CI), the deblurring bound $1/B(\sigpost)$, and the SMC warp error on the training wells. $\dagger$: unstable posterior ($c = 2$).}
\caption{H2b at $N = 16$, wide cells ($\sigpost \ge 1.5$\,ms): band RMSE of \mRML{} divided by that of \mPM{} (95\% CI); the population bounds at $\sigpost$ for Gaussian classical error, $1/B_a$ (registered), and for Gaussian Berkson error, $1/B_b$ (post hoc), computed by blurring and by sharpening the Oracle's predictions (Section~\ref{sec:theory:post}); and the SMC warp error on the training wells. A ratio below a bound is a larger gain than removing that population distortion could give. $\dagger$: unstable posterior ($c = 2$). $\ddagger$: $\sigpost$ exceeds the 6\,ms grid of $B$; the entry is $1/B_a(6\,\mathrm{ms})$, and the bound at $\sigpost$ is 0.481.}
\label{tab:h2b}
\small
\begin{tabular}{lccccccc}
\begin{tabular}{lcccccccc}
\toprule
Regime & $c$ & $\sigpost$ (ms) & ratio & 95\% CI & $1/B$ & warp RMSE (ms) & cov$_{90}$ \\
Regime & $c$ & $\sigpost$ (ms) & ratio & 95\% CI & $1/B_a$ & $1/B_b$ & warp RMSE (ms) & cov$_{90}$ \\
\midrule
R0 & 1 & 1.53 & 0.967 & [0.956, 0.979] & 0.999 & 1.86 & 0.86 \\
R0h & 1 & 1.72 & 0.970 & [0.953, 0.989] & 0.996 & 2.36 & 0.83 \\
R10tb & 1 & 1.92 & 0.890 & [0.866, 0.915] & 0.964 & 4.78 & 0.53 \\
Rm5 & 1 & 2.56 & 0.982 & [0.966, 0.995] & 1.000 & 2.91 & 0.86 \\
R0 & 2$^\dagger$ & 2.79 & 0.952 & [0.940, 0.962] & 0.968 & 2.72 & 0.94 \\
Rm5 & 2$^\dagger$ & 3.96 & 0.964 & [0.953, 0.977] & 0.980 & 3.92 & 0.91 \\
R0h & 2$^\dagger$ & 4.18 & 0.904 & [0.889, 0.925] & 0.910 & 4.10 & 0.94 \\
R10tb & 2$^\dagger$ & 11.49 & 0.667 & [0.615, 0.713] & 0.634 & 19.08 & 0.62 \\
R0 & 1 & 1.53 & 0.967 & [0.956, 0.979] & 0.999 & 0.982 & 1.86 & 0.86 \\
R0h & 1 & 1.72 & 0.970 & [0.953, 0.989] & 0.996 & 0.972 & 2.36 & 0.83 \\
R10tb & 1 & 1.92 & 0.890 & [0.866, 0.915] & 0.964 & 0.893 & 4.78 & 0.53 \\
Rm5 & 1 & 2.56 & 0.982 & [0.966, 0.995] & 1.000 & 0.904 & 2.91 & 0.86 \\
R0 & 2$^\dagger$ & 2.79 & 0.952 & [0.940, 0.962] & 0.968 & 0.768 & 2.72 & 0.94 \\
Rm5 & 2$^\dagger$ & 3.96 & 0.964 & [0.953, 0.977] & 0.980 & 0.285 & 3.92 & 0.91 \\
R0h & 2$^\dagger$ & 4.18 & 0.904 & [0.889, 0.925] & 0.910 & 0.132 & 4.10 & 0.94 \\
R10tb & 2$^\dagger$ & 11.49 & 0.667 & [0.615, 0.713] & 0.634$^\ddagger$ & $<$0.001 & 19.08 & 0.62 \\
\bottomrule
\end{tabular}
\end{table}
@@ -147,7 +156,7 @@ R10tb & 2$^\dagger$ & 11.49 & 0.667 & [0.615, 0.713] & 0.634 & 19.08 & 0.62 \\
\begin{figure}[t]
\centering
\includegraphics[width=\linewidth]{p2r_h2b.pdf}
\caption{H2b. (a) Band RMSE of \mRML{} divided by that of \mPM{} against the posterior width $\sigpost$, for every regime $\times$ $c$ $\times$ $N$ cell (filled: $N = 16$; open: $N = 4$; marker shape: drift factor $c$). Bars are 95\% bootstrap intervals over realizations. The dashed line is the pre-registered 1.5\,ms threshold for wide cells. (b) The same ratio against the deblurring bound $1/B(\sigpost)$ computed from Oracle predictions (Section~\ref{sec:theory:post}). Cells below the diagonal gained more than removing a Gaussian blur could give. Cells at $c = 2$ have an unstable posterior and are not primary evidence.}
\caption{H2b. (a) Band RMSE of \mRML{} divided by that of \mPM{} against the posterior width $\sigpost$, for every regime $\times$ $c$ $\times$ $N$ cell (filled: $N = 16$; open: $N = 4$; marker shape: drift factor $c$). Bars are 95\% bootstrap intervals over realizations. The dashed line is the pre-registered 1.5\,ms threshold for wide cells. (b) The same ratio against the registered population bound $1/B_a(\sigpost)$ for classical error, computed from Oracle predictions (Section~\ref{sec:theory:post}). Cells below the diagonal gained more than removing a classical population blur could give. The bound $1/B_b$ for Berkson error, the natural idealization for labels at the posterior-mean warp, is lower, and at $N = 16$ only three wide cells, all at $c = 1$, lie below it (Table~\ref{tab:h2b}). For R10tb at $c = 2$ the bound is evaluated at the 6\,ms edge of its grid. Cells at $c = 2$ have an unstable posterior and are not primary evidence.}
\label{fig:h2b}
\end{figure}
@@ -162,185 +171,81 @@ The SMC posterior was close to calibrated when the anchors were dense and $\sigm
\end{figure}
\paragraph{Predictive uncertainty (descriptive).}
Every five-seed ensemble under-covered. At R10, $c = 1$, $N = 16$, the 90\% coverage was 0.79 for B5, 0.58 for \mPM-ens, 0.58 for \mRML-ens and 0.48 for Oracle-ens, with calibration errors 0.114, 0.300, 0.291 and 0.379. Ensembles trained on better labels predicted smaller $\sigma$ and covered less. A seed ensemble of a heteroscedastic network does not carry the tie posterior to the test wells. We make no calibration claim.
Every five-seed ensemble under-covered. At R10, $c = 1$, $N = 16$, the 90\% coverage was 0.79 for B5, 0.58 for \mPM-ens, 0.58 for \mRML-ens and 0.48 for Oracle-ens, with calibration errors 0.114, 0.300, 0.291 and 0.379. Ensembles trained on better labels predicted smaller $\sigma$ and covered less.
\subsection{F3 field data (gate G-C)}
\label{sec:exp:f3}
\paragraph{Baselines.}
Table~\ref{tab:p1} gives leave-one-well-out results for the baselines on F3. The label is $\mathrm{PHIE}_{\mathrm{DT}}$, and the reference is the marker-calibrated sonic of the test well. The test well contributes nothing to training, tie, hyperparameters or checkpoint selection. A depth--time trend fitted on the training wells (B0a) has the lowest RMSE. No learned model beats it in total RMSE, and its seismic-band PCC is negative. Seismic-attribute ridge regression (B0b) has the highest band PCC (0.24). Among networks, labels from the marker-calibrated tie (B3b) beat single-anchor sonic integration (B3a). With four wells these numbers are descriptive.
Table~\ref{tab:t4} examines this pattern post hoc, with the dispersion ratio $\xi$ of Section~\ref{sec:theory:cov} computed from the saved test-well predictions. Every ensemble was too narrow: $\xi$ was 0.19 for the Oracle and at most 0.66 (B5), against 1 for a matched second moment. Because $\xi_O$ is small, Proposition~\ref{prop:coverage}(a) requires only a small excess of predicted variance for a method to cover more than the Oracle. Each method had a larger $\xi$ and a higher coverage than the Oracle in 80--99\% of the 240 realization cells. The ordering follows training length as much as label quality. At R10, B3c-R had a median warp error of 3.5\,ms on the training wells, against 0.55\,ms for the SMC mean warp. It was trained for the Oracle's 500 iterations and reached the same $\xi$ as \mPM{} at 250. Over all regimes its excess over the Oracle was the smallest of any method (0.02--0.03). Most of the excess of \mPM{} and \mRML{} was already present at $c = 0$, where the median warp error of their labels was 0.34\,ms. Within the 250-iteration group, the methods with worse labels (B3d, B3c) had the larger excess, as Proposition~\ref{prop:coverage}(b) predicts. Training length acts on its own. On the development realizations of Experiment~1 (SNR 10, $c = 1$, $N = 16$), the 90\% coverage of single Oracle models fell from 0.47 after 125 iterations to 0.23 after 500 and 0.10 after 2000. Their mean $\sigma$ fell by a factor of five, while their RMSE varied by less than 10\%. In Experiment~2 training length and label source are confounded, so parts (b) and (c) of Proposition~\ref{prop:coverage} are not tested. A seed ensemble of a heteroscedastic network does not carry the tie posterior to the test wells. We make no calibration claim.
\begin{table}[t]
\centering
\caption{F3 leave-one-well-out baselines (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, 600--1100\,ms). Macro over four wells; $\pm$: standard deviation over five seeds.}
\label{tab:p1}
\caption{Dispersion of the five-seed ensembles (post hoc, descriptive). Left: R10, $c = 1$, $N = 16$. Iterations: training length selected on development data. rms $s$: root mean predicted variance $\overline{\sigma_s^2} + \Var_s\mu_s$; RMSE of the ensemble mean (p.u.); $\xi$: dispersion ratio of Section~\ref{sec:theory:cov}, averaged over realizations; cov$_{90}$: coverage of the central 90\% Gaussian interval. Right: mean excess $\xi_j - \xi_O$ over the Oracle in the same realization, averaged over the five regimes, both $N$ and eight realizations, by drift factor $c$.}
\label{tab:t4}
\small
\begin{tabular}{lcccc}
\begin{tabular}{lcccccccc}
\toprule
Method & RMSE (p.u.) & PCC & band PCC & skill vs B0a \\
& & \multicolumn{4}{c}{R10, $c = 1$, $N = 16$} & \multicolumn{3}{c}{$\xi_j - \xi_O$} \\
\cmidrule(lr){3-6}\cmidrule(lr){7-9}
Ensemble & iterations & rms $s$ & RMSE & $\xi$ & cov$_{90}$ & $c = 0$ & $c = 1$ & $c = 2$ \\
\midrule
B0a (trend) & \textbf{2.48} & 0.81 & $-0.13$ & 0.00 \\
B0b ridge & 2.58 & \textbf{0.83} & \textbf{0.24} & $-0.09$ \\
B0b random forest & $2.67 \pm 0.01$ & 0.79 & $-0.03$ & $-0.22$ \\
B0b gradient boosting & 2.68 & 0.78 & 0.01 & $-0.20$ \\
B1 (impedance inversion) & 3.60 & 0.44 & $-0.02$ & $-1.29$ \\
B2 (composite loss) & $3.07 \pm 0.16$ & 0.52 & 0.15 & $-0.65$ \\
B3a & $2.93 \pm 0.24$ & 0.62 & $-0.02$ & $-0.47$ \\
B3b & $2.82 \pm 0.21$ & 0.68 & 0.15 & $-0.36$ \\
Oracle & 500 & 0.48 & 1.13 & 0.189 & 0.48 & -- & -- & -- \\
B3c-R & 500 & 0.61 & 1.20 & 0.262 & 0.55 & 0.018 & 0.027 & 0.026 \\
\mPM{} & 250 & 0.58 & 1.15 & 0.265 & 0.58 & 0.032 & 0.051 & 0.058 \\
\mRML{} & 250 & 0.60 & 1.16 & 0.275 & 0.58 & 0.031 & 0.046 & 0.054 \\
B3d & 250 & 0.76 & 1.24 & 0.379 & 0.65 & 0.041 & 0.072 & 0.064 \\
B3c & 250 & 0.74 & 1.23 & 0.372 & 0.64 & 0.058 & 0.072 & 0.064 \\
B5 & 125 & 1.10 & 1.36 & 0.662 & 0.79 & 0.199 & 0.199 & 0.179 \\
\bottomrule
\end{tabular}
\end{table}
\paragraph{Protocol and deviations.}
The field test was pre-registered in a third protocol. Its SHA-256 lock also covers the code, the input data and the software environment, and the scripts refuse to run if any of them changes. The lock file records that it was written one minute before the main run started (28 October 2026, 00:14 and 00:15 local time). The protocol was committed to version control and tagged only after the run, together with the results. The record that the lock preceded the run is therefore the time stamp inside the lock file, which is self-reported, not the version history. Before the lock we ran a timing pilot of the registration and a preflight of the classical baselines on F3. Neither computed a metric on a test well. No result on an F3 test well was used to design it. Two facts limit what the test can show. First, F3 is not an untouched field dataset. The same four wells gave the baselines of Table~\ref{tab:p1}, computed before the protocol was written, and they calibrated the synthetic benchmark (Section~\ref{sec:data:d2}). The field test is therefore a descriptive follow-up on wells we had already seen, not an independent replication. Second, the method under test comes from Experiment~2, whose protocol was itself designed after Experiment~1 had failed (Section~\ref{sec:exp:diag}). The field result therefore bears on the SMC variant only, and it leaves the verdict of Experiment~1 unchanged.
\subsection{Mechanism of the bank gain (exploratory)}
\label{sec:exp:mech}
\todoblock{T2, exploratory, on the Experiment~2 bank (realizations 8--15), declared in \texttt{docs/research/t2-mechanism.md} before it is run (scheduled 1/11/2026). Planned tests: (i) warp error of the responsibility-weighted bank against that of the mean warp, at the end of training (re-registration, Remark~\ref{rem:lambda}); (ii) a control bank of random Gaussian-process time shifts with the same spread (label augmentation); (iii) split of the wide cells by posterior multimodality (Corollary~\ref{cor:twomode}); (iv) the Berkson-versus-classical covariance test of Section~\ref{sec:theory:post} for the bulk offset of \mPM{} and B3c-R, which decides which bound of Table~\ref{tab:h2b} applies; (v) \mPM{} retrained at the Oracle's budget, to separate training length from label error. The question is whether any gain remains beyond the population correction of the Berkson structure, not why a gain exceeds the registered bound. Disclose that the post hoc ratios and both bounds of Section~\ref{sec:exp:p2r}, at $\sigpost$ and at the warp error and with the 60\,Hz and cross-spectral variants, were inspected on 29/10/2026, before the declaration.}
\subsection{Detectability of a gain at blind wells (exploratory)}
\label{sec:exp:detect}
A field test scores predictions at blind wells against labels that need a tie of their own. By Proposition~\ref{prop:reference}, an error in that reference biases the comparison, and more wells reduce its variance but not its bias. To estimate how many blind wells a field test needs, we rescored the saved test predictions of Experiment~2 against perturbed references. The analysis was declared before it was run, but after both field gates had failed (Section~\ref{sec:exp:scope}). After the first run we added points to the grid of reference errors, from $\{0, 2, 4, 8\}$ to $\{0, 0.5, 1, 1.5, 2, 3, 4, 8\}$\,ms, because the outcome changed between 0 and 2\,ms, where the grid had no points. No rule, threshold or input changed. The analysis is exploratory.
\paragraph{Design.}
We used nested leave-one-well-out validation. Each well is held out once as the outer test well. Within the three remaining wells, each is held out once as an inner validation well, and models are trained on the other two. Registration uses only the two training wells of each model: the warp-prior hyperparameters, the wavelet phase and the SMC posterior ($\sigma_a = 7$\,ms, $P = 1024$, $S = 64$) are all estimated from them. For each outer fold, method and seed, the iteration budget is chosen from $\{125, 250, 500, 1000, 2000\}$ by total validation MSE averaged over the three inner wells, with ties going to the smaller budget. This replaces the selection on development realizations used in the synthetic experiments (Section~\ref{sec:method:train}). The prediction at the outer well is a Gaussian with the mean and variance of the equally weighted mixture of 15 members (three inner models $\times$ five seeds). Nothing is refitted on the outer well, and its labels enter no choice. The primary label is $\mathrm{PHIE}_{\mathrm{DT}}$, and the reference is the marker-calibrated sonic of the test well, as in Table~\ref{tab:p1}.
We used the cells at R10, R0 and Rm5 with $c = 1$ and $N \in \{4, 16\}$, and compared \mRML{} with the best point tie of each cell, the competitor of H2a: B3c-R in four cells, B3c at R10 with $N = 4$ and B3b at Rm5 with $N = 4$. For each test well, the reference is the true label read at $t + s(t)$, with $s = a + bx$, where $x$ runs linearly from $-1$ to 1 across the window, $a \sim \N(0, \sigma_{\mathrm{ref}}^2)$ and $b \sim \N(0, \sigma_{\mathrm{ref}}^2/4)$. The RMS of $s$ is then $1.04\,\sigma_{\mathrm{ref}}$. Each well receives 64 draws. A well counts as a win if the seed-averaged \mRML{} has the lower band RMSE against this reference. Wells of one realization share their training wells, so their outcomes are correlated. The probability that a rule passes with $n$ blind wells is therefore computed from a beta-binomial distribution whose mean is the win rate and whose intra-class correlation is that of the outcome within realizations. We compare two rules: $k$ of $n$ wells with $k = \lceil 0.75n\rceil$, the form of both field gates (three of four on F3, five of six on Volve), and a one-sided sign test at $\alpha = 0.05$. $N^\star$ is the smallest $n \le 40$ at which a rule passes with probability at least 0.8.
Gate G-C required two conditions for \mRML{} in this configuration. (i) \emph{Direction}: lower band RMSE than the point tie chosen for that outer fold among B3b, B3c and B3c-R, by inner-validation MSE averaged over seeds, at no fewer than three of the four outer wells. Any reduction counts, so this rule is weaker than the 0.90 ratio of the synthetic experiments. (ii) \emph{Coverage}: macro coverage of the central 80\% and 90\% intervals within $\pm 0.05$ of nominal, that is, in $[0.75, 0.85]$ and $[0.85, 0.95]$. Coverage is the fraction of time samples in the window that fall inside the interval. These samples are strongly correlated, so coverage is a description, not a test. The protocol also states that better accuracy cannot compensate for failed coverage. Before the run we had recorded that the coverage condition would probably fail, because every ensemble had under-covered in the synthetic experiments. We kept the threshold.
\paragraph{A reference error of a few milliseconds reverses the ranking.}
With an exact reference, \mRML{} won at 81--97\% of the test wells, and its median band RMSE was 0.80--0.92 times that of the competitor (Table~\ref{tab:t3}). Both numbers worsened as the reference error grew. At $\sigma_{\mathrm{ref}} = 4$\,ms, the win rate was 0.46--0.64 and the median ratio 0.96--1.01. At 8\,ms, the win rate was 0.22--0.44 and the median ratio exceeded 1 in every cell: against this reference the point tie scored better, although against the true labels it was worse. In the three cells with $N = 16$, the median ratio crossed 1 between 3.6 and 4.3\,ms. Corollary~\ref{cor:tolerance} places the crossing, to leading order and without shrinkage, at $\sigma/\sqrt2$, where $\sigma$ is the tie error of the point label. The RMS warp error of B3c-R on the training wells of these cells was 4.2, 5.8 and 7.3\,ms at R10, R0 and Rm5, so $\sigma/\sqrt2$ is 3.0, 4.1 and 5.1\,ms. The simulated crossings follow the same order and lie within 1\,ms of these values. The agreement can only be approximate: \mRML{} is not the oracle that the corollary assumes, the tie errors are not constant Gaussian shifts, and the reference error here includes a stretch.
\paragraph{Result: the gate failed.}
Both conditions failed (Table~\ref{tab:f3gc}). Inner validation chose B3c-R as the competitor at all four outer wells. \mRML{} had lower band RMSE only at F03-4, by 1.9\%. At F02-1 and F03-2 it was 0.8\% and 0.02\% worse, and at F06-1 it was 7.0\% worse. Its macro band RMSE was 1.272\,p.u., against 1.256\,p.u.\ for B3c-R. Macro coverage was 0.524 for the 80\% intervals and 0.609 for the 90\% intervals, far below the lower limits of 0.75 and 0.85. At F03-2 and F03-4 the 80\% and 90\% intervals covered 0.75 and 0.80 of the samples, just below and well below nominal. At F02-1 and F06-1 they covered 0.22--0.38 and 0.33--0.50. At these two wells most of the error lay below 6\,Hz: the low-band RMSE was 4.31 and 3.64\,p.u., out of a total RMSE of 4.56 and 3.82\,p.u., while the mean predicted standard deviation was 1.05 and 1.27\,p.u. Seed by seed (three-member ensembles), \mRML{} beat B3c-R at one to three of the four wells. The macro band RMSE of each method varied between seeds by up to 0.13\,p.u.\ (\mRML: 1.28--1.41\,p.u.; B3c-R: 1.29--1.41\,p.u.), eight times the gap between the combined ensembles. The competitor was not changed after the test wells were scored, and the intervals were not widened. Under this protocol, training on the SMC bank gave no band-RMSE gain over the best point tie on F3, and its predictive intervals were much too narrow. We make no claim of improvement on field data and no claim of calibrated uncertainty.
\paragraph{Wells needed.}
With an exact reference, the sign test needs five blind wells at R0 (both $N$) and at R10 with $N = 16$, and 18 and 11 wells at Rm5 with $N = 4$ and 16. At R10 with $N = 4$, the outcomes are strongly correlated within realizations (intra-class correlation 0.45), and no $n \le 40$ reaches a pass probability of 0.8. The number of wells rises quickly with the reference error. At 1\,ms, four of the six cells need 11--30 wells; at 2\,ms, only R0 stays within 40 (23 and 37 wells); at 3\,ms or more, no cell does. The $k$-of-$n$ rule appears to need fewer wells, but it is not a test. With independent wells and no true difference, it passes with probability $5/16 = 0.31$ at $n = 4$ and $7/64 = 0.11$ at $n = 6$. A one-sided sign test at $\alpha = 0.05$ cannot reject at all with four wells, because its smallest attainable $p$-value is $1/16$.
\begin{table}[t]
\centering
\caption{Gate G-C on F3 (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, 600--1100\,ms, $\sigma_a = 7$\,ms, 15-member ensemble). Competitor: the point tie chosen by inner validation. Ratio: band RMSE of \mRML{} divided by that of the competitor; at F03-2 it is 1.0002. Coverage: fraction of the 126 time samples inside the central interval of \mRML; at F03-2 and F03-4 the same counts (94 and 101 samples) occur by coincidence.}
\label{tab:f3gc}
\caption{Detectability at blind wells (exploratory; saved test predictions of Experiment~2, $c = 1$). Competitor: the best point tie of the cell. Win: fraction of the 64 test wells at which \mRML{} has the lower band RMSE against the perturbed reference; ratio: median ratio of band RMSE, \mRML{} to competitor; ICC: intra-class correlation of the win within realizations. $N^\star$: smallest number of blind wells at which a one-sided sign test ($\alpha = 0.05$) rejects with probability at least 0.8; --: not reached with 40 wells.}
\label{tab:t3}
\small
\begin{tabular}{lccccc}
\setlength{\tabcolsep}{4pt}
\begin{tabular}{llccccccccccc}
\toprule
Outer well & competitor & ratio & improved & cov$_{80}$ & cov$_{90}$ \\
& & \multicolumn{3}{c}{$\sigma_{\mathrm{ref}} = 0$} & \multicolumn{2}{c}{win} & \multicolumn{6}{c}{$N^\star$ at $\sigma_{\mathrm{ref}}$ (ms)} \\
\cmidrule(lr){3-5}\cmidrule(lr){6-7}\cmidrule(lr){8-13}
Cell & Competitor & win & ratio & ICC & 4\,ms & 8\,ms & 0 & 0.5 & 1 & 1.5 & 2 & $\ge 3$ \\
\midrule
F02-1 & B3c-R & 1.008 & no & 0.222 & 0.333 \\
F03-2 & B3c-R & 1.000 & no & 0.746 & 0.802 \\
F03-4 & B3c-R & 0.981 & yes & 0.746 & 0.802 \\
F06-1 & B3c-R & 1.070 & no & 0.381 & 0.500 \\
\midrule
Macro & & & 1/4 & 0.524 & 0.609 \\
Required & & & $\ge 3/4$ & $[0.75, 0.85]$ & $[0.85, 0.95]$ \\
R10, $N = 4$ & B3c & 0.81 & 0.85 & 0.45 & 0.53 & 0.39 & -- & -- & -- & -- & -- & -- \\
R10, $N = 16$ & B3c-R & 0.97 & 0.80 & 0.00 & 0.46 & 0.22 & 5 & 5 & 11 & 23 & -- & -- \\
R0, $N = 4$ & B3c-R & 0.95 & 0.87 & 0.07 & 0.64 & 0.39 & 5 & 8 & 11 & 13 & 23 & -- \\
R0, $N = 16$ & B3c-R & 0.97 & 0.87 & 0.00 & 0.48 & 0.27 & 5 & 8 & 13 & 18 & 37 & -- \\
Rm5, $N = 4$ & B3b & 0.84 & 0.92 & 0.39 & 0.60 & 0.44 & 18 & 30 & -- & -- & -- & -- \\
Rm5, $N = 16$ & B3c-R & 0.89 & 0.92 & 0.08 & 0.51 & 0.31 & 11 & 16 & 30 & -- & -- & -- \\
\bottomrule
\end{tabular}
\end{table}
\paragraph{Relation to Experiment~2.}
In the synthetic benchmark, \mRML{} beat the best point tie in all three full-anchor regimes, under a stricter rule (Section~\ref{sec:exp:p2r}). On F3 this direction held at one well of four. The field test does not show why, and we tested no explanation. Two features of F3 limit what it can detect. First, the synthetic gains required a correctly specified $\sigma_a$ (Table~\ref{tab:sigmaa}). On F3, $\sigma_a$ is not identified: 7\,ms comes from the marker--horizon spread (Section~\ref{sec:data:f3}), not from an independent measurement. Second, the reference is itself a point tie, the marker-calibrated sonic of B3b. Its registration error adds to the band RMSE of every method, which pulls ratios towards one, and it favours methods whose label errors resemble its own. Neither feature changes the verdict.
\subsection{Scope: two field cases}
\label{sec:exp:scope}
\begin{table}[t]
\centering
\caption{F3 nested leave-one-well-out, all methods (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, $\sigma_a = 7$\,ms, combined ensembles). Macro over four wells; RMSE in p.u. Coverage is descriptive. Last row: a prediction with no content above $f_c$, whose band RMSE equals the RMS of the band component of the reference; computed after the run, for scale only.}
\label{tab:f3all}
\small
\begin{tabular}{lcccccc}
\toprule
Method & band RMSE & band PCC & RMSE & PCC & cov$_{80}$ & cov$_{90}$ \\
\midrule
B0a (trend) & 1.239 & $-0.13$ & \textbf{2.48} & 0.81 & -- & -- \\
B0b ridge & 1.271 & \textbf{0.24} & 2.58 & \textbf{0.83} & -- & -- \\
B0b random forest & 1.511 & $-0.03$ & 2.67 & 0.79 & -- & -- \\
B0b gradient boosting & 1.537 & 0.01 & 2.68 & 0.78 & -- & -- \\
B1 (impedance inversion) & 3.090 & $-0.02$ & 3.60 & 0.44 & -- & -- \\
B2 (composite loss) & 1.252 & 0.19 & 3.09 & 0.53 & 0.38 & 0.44 \\
\midrule
B3a & 1.348 & $-0.01$ & 3.13 & 0.44 & 0.47 & 0.57 \\
B3b & 1.284 & 0.16 & 3.07 & 0.52 & 0.50 & 0.59 \\
B3c & 1.282 & 0.20 & 3.14 & 0.45 & 0.48 & 0.58 \\
B3c-R & 1.256 & 0.20 & 2.98 & 0.59 & 0.51 & 0.59 \\
B3d & 1.266 & 0.16 & 3.05 & 0.52 & 0.51 & 0.60 \\
\mPM & 1.275 & 0.15 & 3.00 & 0.57 & 0.47 & 0.57 \\
\midrule
B4a & 1.232 & 0.18 & 3.24 & 0.39 & 0.49 & 0.58 \\
B4b & \textbf{1.211} & 0.22 & 3.17 & 0.43 & 0.49 & 0.60 \\
B4c & 1.237 & 0.22 & 3.12 & 0.57 & 0.42 & 0.52 \\
B4d & 1.254 & 0.21 & 3.14 & 0.57 & 0.47 & 0.58 \\
\midrule
M1 & 1.286 & 0.13 & 3.14 & 0.49 & 0.50 & 0.58 \\
\mRML & 1.272 & 0.18 & 3.12 & 0.49 & \textbf{0.52} & \textbf{0.61} \\
\midrule
No band content & 1.224 & -- & -- & -- & -- & -- \\
\bottomrule
\end{tabular}
\end{table}
\paragraph{Both field gates failed.}
We ran two field tests under locked protocols. On F3, with four wells, gate G-C required \mRML{} to have a lower band RMSE than the selected point tie at no fewer than three of the four blind wells, and macro coverage of its 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$. On Volve, with six deviated wells and a density-driven porosity label, gate G-D asked for the same at five of six wells under two hold-out schemes, with total RMSE on the labelled samples. Both gates failed. On F3, \mRML{} improved at one well of four, and coverage was 0.52 and 0.61. Its sensitivity variants (anchor uncertainty, scoring reference, band split, label) improved at one to three wells and never met the coverage condition. On Volve, \mRML{} improved at two (leave-one-well-out) and three (slot) of six wells, and coverage of the 90\% interval was 0.48 and 0.47. No method had skill at the Volve blind wells: $R^2$ was negative for every method, and a constant at the training-well mean of PHIF had a lower macro RMSE than every network (6.03 and 6.59\,p.u.\ under the two schemes, against 6.50 and 7.13\,p.u.\ for \mRML; post hoc). Appendix~\ref{app:field} gives the designs, all tables and the protocol deviations. Neither test is an independent replication. F3 also supplied the statistics and the warp prior of the synthetic generator (Section~\ref{sec:data:d2}), and the Volve test was designed after the F3 gate had failed.
\paragraph{All methods.}
Table~\ref{tab:f3all} lists every method under the nested design. B0a, B0b and B1 use the code of Table~\ref{tab:p1} and reproduce its values. The networks have higher total RMSE than in Table~\ref{tab:p1} (B3b: 3.07 against 2.82\,p.u.); here each model is trained on two wells rather than three, and its budget is chosen by inner validation. Only B4b had a lower macro band RMSE than a prediction with no seismic-band content (1.211 against 1.224\,p.u.). B0a, which has almost no band content, came within 1.3\% of that value, and every point tie, \mPM{} and \mRML{} lay above it. Band PCC did not exceed 0.22 for any network. On F3 the networks therefore predicted little of the seismic-band variation of the label, and G-C compared methods whose band errors were nearly the same size: without B3a, the 13 networks span 1.211--1.286\,p.u. The ranking also differs from the synthetic experiments. All four anchor-free losses, B4a--B4d, had lower macro band RMSE than every point tie, \mPM{} and \mRML, by up to 0.06\,p.u. Every probabilistic method under-covered. Macro coverage was 0.38--0.52 for the 80\% intervals and 0.44--0.61 for the 90\% intervals, and \mRML{} had the highest values of both.
\paragraph{Neither test could have detected the effect.}
After both gates had failed, we stated four conditions under which a field test of this kind bears on the synthetic result, and evaluated them without test labels. The thresholds of C1 and C2 were taken mechanically from Experiment~2, so the conditions are post hoc but were not tuned to the field results. (C1) The networks have blind-well skill within the range in which Experiment~2 found the effect: at inner-validation wells, a band PCC of at least 0.468 and an $R^2$ of at least 0.053, the smallest values reached by the best point tie in the cells that passed H2a, and a lower RMSE than a constant. (C2) The tie posterior is wide, $\sigpost \ge 1.5$\,ms, the threshold of H2b; this condition matters only for the comparison with \mPM. (C3) $\sigma_a$ is identified by independent time--depth data at three or more wells outside the test set, because a misset $\sigma_a$ removed the H2a advantage (Table~\ref{tab:sigmaa}). (C4) The number of blind wells reaches $N^\star$ (Table~\ref{tab:t3}). C2 held on both datasets, with median $\sigpost$ of 2.8\,ms on F3 and 4.3\,ms on Volve. C1 failed on both: band PCC at the inner-validation wells was 0.15 on F3 and 0.13 and 0.04 on Volve (leave-one-well-out and slot), and $R^2$ was 0.04, $-0.99$ and $-0.99$. C3 and C4 fail by construction. F3 has no independent time--depth data, and Volve has check shots at two wells. Both tests scored against marker-calibrated sonic ties of the test wells, whose errors are unknown. With four wells no sign test can reject, and with independent wells the gate rules pass with probability 0.31 (three of four) and 0.11 (five of six) when there is no true difference. The failure of either gate is therefore no evidence against the synthetic result, and a pass would not have been evidence for it.
\paragraph{Same posterior, $\sigma_a$ and scoring reference.}
The protocol prescribes four further comparisons. None can replace a G-C condition, and none was used to choose a result. Table~\ref{tab:f3sens} gives the per-well ratios. In no row did the coverage condition hold.
(a) Against \mPM, which is trained on the mean of the same SMC posterior, \mRML{} had lower band RMSE at two wells (F02-1 and F03-4) and higher band RMSE at F03-2, by 9.3\%. Its macro band RMSE was 0.003\,p.u.\ lower.
(b) With $\sigma_a = 3.5$ or 14\,ms, B3c-R, \mPM{} and \mRML{} were registered and trained again, and \mRML{} was compared with B3c-R at the same $\sigma_a$. It had lower band RMSE at one and two of the four wells, and the wells that improved were not the same in the three arms. Macro coverage was 0.47--0.48 and 0.57--0.59.
(c) When the test well is scored against the OpendTect time--depth model instead of the marker-calibrated sonic, \mRML{} again improved only at F03-4. We also scored each method against 64 warps of the test well, drawn from an anchor-only posterior whose prior was fitted on the other three wells. The 5--95\% range of band RMSE over these references was 0.06--0.15\,p.u.\ wide for \mRML{} and for B3c-R, and the ranges of the two methods overlapped at F02-1, F03-2 and F03-4. At F06-1 they did not overlap (\mRML: 1.13--1.18\,p.u.; B3c-R: 1.04--1.11\,p.u.).
(d) Moving the band cutoff to 5 or 8\,Hz changed no ratio by more than 0.01. With the original PHIE label, \mRML{} improved at three wells, but coverage was lower (0.45 and 0.50). In the window the two labels differ by an RMS of 3.2\,p.u.\ at F02-1 and by less than 0.02\,p.u.\ at the other wells. F02-1 is a training well in three of the four outer folds, and the ratios at those three test wells moved by up to 0.13. This shows how much a ratio near one depends on the label of a single training well. The gate is defined on $\mathrm{PHIE}_{\mathrm{DT}}$, and this row does not change its result.
\begin{table}[t]
\centering
\caption{F3 sensitivity of the G-C comparison (combined ensembles, descriptive). Ratio: band RMSE of \mRML{} divided by that of B3c-R, except in the second row (\mRML{} divided by \mPM). In the $\sigma_a$ rows both methods use the stated $\sigma_a$. Coverage is that of \mRML{} and does not depend on $f_c$ (--). At F03-2 with $f_c = 5$\,Hz the ratio is 1.00002.}
\label{tab:f3sens}
\small
\begin{tabular}{lccccccc}
\toprule
Variant & F02-1 & F03-2 & F03-4 & F06-1 & improved & cov$_{80}$ & cov$_{90}$ \\
\midrule
Registered (Table~\ref{tab:f3gc}) & 1.008 & 1.000 & 0.981 & 1.070 & 1/4 & 0.52 & 0.61 \\
\mRML{} / \mPM & 0.970 & 1.093 & 0.941 & 1.012 & 2/4 & -- & -- \\
$\sigma_a = 3.5$\,ms & 1.010 & 0.939 & 1.003 & 1.034 & 1/4 & 0.48 & 0.59 \\
$\sigma_a = 14$\,ms & 0.989 & 0.959 & 1.020 & 1.035 & 2/4 & 0.47 & 0.57 \\
OpendTect reference & 1.022 & 1.018 & 0.974 & 1.071 & 1/4 & 0.50 & 0.60 \\
$f_c = 5$\,Hz & 1.002 & 1.000 & 0.980 & 1.079 & 1/4 & -- & -- \\
$f_c = 8$\,Hz & 1.014 & 0.997 & 0.979 & 1.060 & 2/4 & -- & -- \\
PHIE label & 0.992 & 0.911 & 1.025 & 0.943 & 3/4 & 0.45 & 0.50 \\
\bottomrule
\end{tabular}
\end{table}
\paragraph{Posterior width and anchors.}
At $\sigma_a = 7$\,ms, $\sigpost$ of the SMC posterior ranged from 1.7 to 3.6\,ms over the 12 training wells of the six training pairs (median 2.8\,ms). Seven of the 12 values lay in the range of 2.5--3.4\,ms estimated before the run from all four wells. By the rule of Experiment~2 every pair is therefore wide ($\sigpost \ge 1.5$\,ms), the regime in which RML helped at $N = 16$. Each F3 model, however, is trained on two wells, and \mRML{} beat \mPM{} at two of the four outer wells (Table~\ref{tab:f3sens}). The width followed $\sigma_a$: it was 1.2--2.3\,ms at $\sigma_a = 3.5$\,ms and 1.8--6.2\,ms at 14\,ms. Without anchors it was 17--38\,ms at F02-1, F03-2 and F03-4, and 1.4--2.0\,ms at F06-1. The wavelet phase was poorly identified. The six phases estimated at $\sigma_a = 7$\,ms spread over an arc of 214$^\circ$. Over the phases evaluated for each pair, a window 90--120$^\circ$ wide, the summed log evidence of the two wells changed by only 1.0--5.0\,nats.
Leave-one-anchor-out $z$-scores test the anchor prior on the outer wells. For each well, a linearized Gaussian process conditioned on the anchors alone, with hyperparameters fitted on the other three wells and pick noise $\sigma_a = 7$\,ms, predicts each anchor time from the remaining anchors of that well. Of 62 held-out anchors, 61 lay inside the 90\% interval. The mean $z^2$ was 0.21 (per well: 0.20, 0.01, 0.01 and 0.59), against an expected value of 1. The anchor prior is therefore too wide rather than too narrow, the same direction as the type-II estimate of $\sigma_a$ (0.4\,ms, Section~\ref{sec:method:prior}) and the opposite direction to the under-coverage of porosity. This check does not test the calibration of the SMC posterior, which also depends on the seismic likelihood and the wavelet phase.
\paragraph{Ablations (descriptive).}
The protocol lists twelve variants of \mRML{} on $\mathrm{PHIE}_{\mathrm{DT}}$ (Table~\ref{tab:f3abl}). They were scored like every other method, but none enters G-C. M2-anchor-only trains on the 64 anchor-only warps of M1 with the same weights, so it reproduces M1 exactly. Nine of the other eleven variants had lower macro band RMSE than \mRML. The variants spanned 1.242--1.309\,p.u., about four times the gap of 0.016\,p.u.\ between \mRML{} and B3c-R. Bank size had no consistent effect: with 1, 8, 64 and 256 SMC labels, band RMSE was 1.273, 1.256, 1.272 and 1.257\,p.u. A convolutional backbone without the GRU lowered band RMSE by about 2\% for both \mRML{} (M2-TCN) and \mPM{} (B3d-Sa-TCN), so it did not change their order. Removing the anchors (M2-no-anchors) lowered band RMSE to 1.247\,p.u.\ but gave the highest total RMSE of the variants (3.23\,p.u.). M2-fixed-sigma was the only variant with coverage close to nominal (0.87 and 0.92), and this is not calibration. Its predicted standard deviation is fixed at the standard deviation of the training labels, which gave 2.9--4.3\,p.u.\ after mixing, against 1.0--2.1\,p.u.\ for \mRML. Its 80\% intervals covered every sample at F03-2 and F03-4 and 0.74 and 0.73 of the samples at F02-1 and F06-1. The macro value is an average of these, not evidence of correct width. M2-LFM adds the low-pass mean label of the training wells as an input channel. It had the lowest total RMSE of any network (2.62\,p.u., against 2.48\,p.u.\ for B0a) and the highest band RMSE of the variants (1.309\,p.u.). Its gain lies below $f_c$, where the gate does not score.
\begin{table}[t]
\centering
\caption{Ablations of \mRML{} on F3 (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, $\sigma_a = 7$\,ms, combined ensembles; descriptive). Macro over four wells; RMSE in p.u. M2-anchor-only is identical to M1 by construction.}
\label{tab:f3abl}
\small
\begin{tabular}{l>{\raggedright\arraybackslash}p{6.4cm}cccc}
\toprule
Variant & change from \mRML & band RMSE & RMSE & cov$_{80}$ & cov$_{90}$ \\
\midrule
\mRML & registered method: 64 SMC labels, CNN--GRU backbone & 1.272 & 3.12 & 0.52 & 0.61 \\
\midrule
M2-anchor-only & 64 anchor-only warps (= M1) & 1.286 & 3.14 & 0.50 & 0.58 \\
M2-no-anchors & no anchor conditioning; prior hyperparameters at the pre-declared medians & 1.247 & 3.23 & 0.48 & 0.56 \\
M2-bulk & sonic integration plus a constant shift, resampled by the seismic likelihood & 1.251 & 3.16 & 0.49 & 0.58 \\
M2-lambda1 & $\lambda = 1$ instead of $1/\tau_c$ & 1.257 & 3.09 & 0.52 & 0.62 \\
M2-S1 & 1 SMC label & 1.273 & 3.08 & 0.48 & 0.57 \\
M2-S8 & 8 SMC labels & 1.256 & 3.11 & 0.48 & 0.59 \\
M2-S256 & 256 SMC labels & 1.257 & 3.10 & 0.50 & 0.58 \\
M2-fixed-sigma & $\sigma$ fixed at the training-label standard deviation & 1.242 & 3.08 & 0.87 & 0.92 \\
M2-legacy-loss & composite loss of B2 on the bank mean added & 1.243 & 3.11 & 0.41 & 0.49 \\
M2-TCN & four dilated convolutions, no GRU & 1.245 & 3.10 & 0.38 & 0.48 \\
B3d-Sa-TCN & \mPM{} with the M2-TCN backbone & 1.250 & 3.13 & 0.40 & 0.49 \\
M2-LFM & low-pass mean training label as an extra input & 1.309 & 2.62 & 0.40 & 0.50 \\
\bottomrule
\end{tabular}
\end{table}
\paragraph{Predicted volume (descriptive).}
A deployment ensemble of \mRML{} predicted all 649 interior inlines of the survey (Fig.~\ref{fig:f3vol}). It has 20 members: four three-well training sets $\times$ five seeds. The map shows sonic-derived porosity and its ensemble standard deviation. Away from the wells there is no ground truth, and three of the four training sets include any given well, so the prediction at a well is not blind. The same kind of ensemble under-covered at the outer wells, so its standard deviation is not a calibrated error bar. Over the $649 \times 949$ interior traces and the 600--1100\,ms window, the median of the predicted mean was 29.6\,p.u.\ (5--95\% of samples: 27.9--31.5\,p.u.). The median standard deviation was 1.3\,p.u.\ (5--95\%: 0.8--2.5\,p.u.). It was larger above 700\,ms (median 2.0\,p.u.) than below (1.2\,p.u.). Even the median standard deviation is less than half the total RMSE of \mRML{} at the outer wells (3.12\,p.u.).
\begin{figure}[t]
\centering
\includegraphics[width=\linewidth]{f3_volume.pdf}
\caption{Descriptive prediction of sonic-derived porosity ($\mathrm{PHIE}_{\mathrm{DT}}$) on F3 inline 442, through F03-4 (dashed line): (a) mean and (b) standard deviation of the 20-member \mRML{} deployment ensemble. Colour limits: 1st--99th percentile of the section for (a), 0 to the 99th percentile for (b). Three of the four training sets include F03-4, so the prediction at the well is not blind. Intervals from this kind of ensemble under-covered at the outer wells (Table~\ref{tab:f3gc}).}
\label{fig:f3vol}
\end{figure}
\paragraph{Execution.}
The run stopped once, after 132 of 649 volume inlines, when the operating system refused to replace a progress-display file. By then the gate had been computed. Only volume inference was resumed, with the locked code and models. Registration, training and scoring were not rerun, and the 132 inlines written before the stop were verified to be unchanged.
\subsection{Second field dataset}
\label{sec:exp:volve}
\todoblock{Volve results (gate G-D): same nested protocol, porosity from density--neutron (independent of sonic), comparison of \mPM{} and \mRML{} with the best point tie. If Volve is cut, delete this subsection and every reference to it.}
\paragraph{Limits of field validation.}
A dataset with more wells does not by itself remove the constraint. After the field tests we inventoried Teapot Dome (NPR-3, Wyoming; \citealp{bader2017teapot}), where 152 wells inside the 3-D survey have density logs across a common target interval. This step is post hoc and exploratory. Its conditions were declared before the data were obtained, and the alternative reference described next was declared after the inventory but before any residual or porosity value was computed. Time--depth tables exist at four wells. Three are labelled as derived from synthetic seismograms, and the fourth, a vertical seismic profile, ends above the main reservoirs. Even counting one of the three as independent, at most two wells have an independent time--depth reference, against the $3 + 11$ that C3 and C4 need at Rm5. As an alternative reference, we paired the times of two interpreted 3-D horizons at the wells with the depths of the corresponding formation tops. On 37 development wells we predicted each time from the depth with a quadratic lateral trend of average velocity, fitted by leave-one-out. The residual standard deviation was 6.75\,ms (90\% bootstrap interval over wells 4.1--9.4\,ms; robust estimate 5.0\,ms). Most of it was a bulk shift per well (6.6\,ms): the residuals of the two horizons at a well were correlated (0.85), and those of neighbouring wells were not. The shift is therefore not a smooth velocity change that the trend missed; it resembles per-well errors of datum, statics or top picks. The differential part was 2.8\,ms, and 2.5\,ms from the sonic at five wells. Every estimate exceeded the declared tolerance of 1.5\,ms, the largest grid value at which the Rm5 cell with $N = 16$ reaches a power of 0.8 with no more than the 115 remaining wells. We therefore stopped before reading any porosity value. One dataset is not a survey, but in this one the binding constraint on field validation was the error of the scoring reference, not the number of wells.