Complete GP manuscript checks and verify revision artifacts

Move the comparator definitions and core evidence into the main text and
lead with effect sizes and intervals. Preserve the locked verdicts and
record the independent GP-D referee report.

Archive the saved GP results and regenerate 43 outputs in the clean
room. Add a source-backed numerical guard for the submission and
record the correction to anchor warp RMSE and the scope of the pooled
blind-well power estimates.

Co-Authored-By: Codex <noreply@openai.com>
This commit is contained in:
2026-11-18 04:08:10 +00:00
parent eff975cc96
commit 1985fcfa02
19 changed files with 28322 additions and 89 deletions

View File

@@ -121,7 +121,7 @@ SNR & $\sigma_a^{\mathrm{reg}}$ (ms) & ratio $N = 4$ & ratio $N = 16$ & pass & $
& 7 & 0.857 [0.805, 0.922] & 0.782 [0.748, 0.813] & 2/2 & 0.59 & 0.63 & 0.89 \\
& 14 & 0.985 [0.897, 1.067] & 0.928 [0.867, 1.004] & 0/2 & 0.92 & 2.81 & 0.52 \\
\midrule
$-5$\,dB & 3.5 & 0.989 [0.967, 1.009] & 1.024 [1.009, 1.037] & 0/2 & 2.89 & 5.94 & 0.53 \\
$-5$\,dB & 3.5 & 0.989 [0.967, 1.009] & 1.024 [1.009, 1.037] & 0/2 & 2.89 & 5.93 & 0.53 \\
& 7 & 0.915 [0.883, 0.953] & 0.923 [0.908, 0.940] & 2/2 & 2.56 & 2.91 & 0.86 \\
& 14 & 0.984 [0.952, 1.013] & 0.978 [0.954, 1.008] & 0/2 & 3.20 & 4.60 & 0.72 \\
\bottomrule
@@ -382,7 +382,7 @@ With an exact reference, the sign test needs five blind wells at 0\,dB (both $N$
The clustering matters. Under a beta-binomial null with intra-class correlation 0.1, the nominal sign test at $\alpha = 0.05$ rejects a true null with probability 0.05 at 10 wells, 0.13 at 20 and 0.23 at 40; at 0.45, the value of the 10\,dB cell with $N = 4$, these become 0.24, 0.34 and 0.40. We therefore recomputed $n_{\mathrm{b}}^\star$ with the critical value chosen so that the size is at most 0.05 under the intra-class correlation of each cell (post hoc, declared before it was computed; Appendix~\ref{app:record:review}). With an exact reference, the 0\,dB cell with $N = 4$ then needs 10 wells instead of 5, the $-5$\,dB cell with $N = 16$ needs 18 instead of 11, and the $-5$\,dB cell with $N = 4$ no longer reaches power 0.8 within 40 wells. The three other cells are unchanged. Because a shared training set affects all blind wells of a realization alike, the power of the calibrated test does not approach 1 as wells are added: its limit is 0.37 and 0.46 in the two cells with $N = 4$ at 10 and $-5$\,dB. At $\sigma_{\mathrm{ref}} = 0.5$\,ms three cells still reach 0.8 (5, 11 and 20 wells), at 1\,ms two (16 and 25 wells, both with $N = 16$), and at 1.5\,ms or more none. The intra-class correlations come from eight realizations and are imprecise, so these numbers indicate an order of magnitude.
\paragraph{Estimand, assumptions and scope.}
The win rate estimates the probability that, for the networks trained on one training set, the \mRML{} has a lower band RMSE than the best deterministic tie at a blind well drawn from the same field. It is conditional on the training set, not an average over training sets: the clustering of wells that share training data is what makes the nominal sign test anti-conservative. The intra-class correlation (0.45 at most here) was measured from the test wells of eight realizations; it cannot be estimated from one field with a few blind wells, so a field analyst must assume or bound it. The reference error is Gaussian, has the form of the design above and is independent of the predictions, and the crossing point $\sigma/\sqrt2$ assumes an unshrunk oracle (Corollary~\ref{cor:tolerance}). The accuracy needed, about 1\,ms for a feasible test, is a phase error of $18^\circ$ at 50\,Hz, and a time--depth reference independent of the seismic data at that accuracy is demanding. These numbers are conditions for a powered blind-well test in this benchmark, not a standard, and we do not show that they can be met in the field.
For a fixed set of trained networks, the target is the probability that the \mRML{} has a lower band RMSE than the best deterministic tie at a blind well drawn from the same field. The power calculation here uses the win rate pooled across realizations and a beta-binomial model for the dependence of wells within a realization. Its power therefore averages over the variation represented by those realizations. The intra-class correlation (0.45 at most here) was measured from the test wells of eight realizations; it cannot be estimated from one field with a few blind wells, so a field analyst must assume or bound it. The reference error is Gaussian, has the form of the design above and is independent of the predictions, and the crossing point $\sigma/\sqrt2$ assumes an unshrunk oracle (Corollary~\ref{cor:tolerance}). The accuracy needed, about 1\,ms for a feasible test, is a phase error of $18^\circ$ at 50\,Hz, and a time--depth reference independent of the seismic data at that accuracy is demanding. These numbers are conditions for a powered blind-well test in this benchmark, not a standard, and we do not show that they can be met in the field.
\paragraph{A worked example.}
Consider a comparison at $-5$\,dB with $N = 16$ training wells, where the best deterministic tie has a warp error of $\sigma = 7.3$\,ms on the training wells. Corollary~\ref{cor:tolerance} requires a reference error below $\sigma/\sqrt2 = 5.1$\,ms for the measured advantage to keep its sign, and in the simulation the ranking reversed at 4.3\,ms. Detecting the gain requires much more. A sign test with a power of 0.8 needs 11 blind wells with an exact reference, 16 with $\sigma_{\mathrm{ref}} = 0.5$\,ms and 30 with 1\,ms, and at 1.5\,ms or more 40 wells do not suffice (Table~\ref{tab:t3}). With its null calibrated for wells that share training data, it needs 18 wells with an exact reference, and at 0.5\,ms or more 40 wells do not suffice. An analyst who can estimate the reference error can read the required number of wells from this table, for predictors of comparable skill. The alternative reference we built for Teapot Dome has a residual of 6.75\,ms (Section~\ref{sec:exp:scope}), which exceeds even the limit for the sign of the comparison.