Report the bank-size ablation (exploratory)
Nested SMC banks of 16, 64, 256 and 1024 members (same particles, same
lambda = 1/tau_c) in the 11 T2 cells at N = 16, 250 iterations; declared
and hashed before computing (05f822b). Retraining reproduced 7,040/7,040
hash-locked rows exactly. Over the 8 wide cells: S256/S64 0.961-1.005
("no gain"), S1024/S64 0.936-0.998 ("mixed", CI below 1 in 4/8, above
in none), S16/S64 1.003-1.059 (CI above 1 in 3/8). S = 64 may have
slightly understated the bank gain (up to about 2% at c = 1). S_eff grows
in proportion to S.
Paper: one sentence in Sec. 4, App. C paragraph "Bank size", Limitations
"Tempering and bank size". No verdict, threshold or locked protocol changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -31,7 +31,7 @@ where $\mathbf r_w$ is the reflectivity computed from acoustic impedance $\mathr
|
||||
We draw $S = 64$ warps per well from the anchor-conditioned posterior. The proposal is a Laplace (Gauss--Newton) approximation, refined by elliptical slice sampling \citep{murray2010ess}. Physical weights $\pi_s \propto p(\mathbf s_w\mid u^{(s)})^{\omega'}$ use the largest exponent $\omega'$ that keeps the effective sample size at least $S/4$.
|
||||
|
||||
\paragraph{Sequential Monte Carlo posterior (Experiment~2).}
|
||||
Importance weights over 64 anchor-conditioned samples cannot move mass to warps that the anchor posterior rarely proposes, and in development runs that posterior did not contract to the true warp (Section~\ref{sec:exp:diag}). The second posterior therefore uses tempered sequential Monte Carlo. It starts from $N_p = 1024$ anchor-posterior samples and targets $p(u\mid \text{anchors})\, p(\mathbf s_w\mid u, \psi)^{\omega}$. The tempering exponent rises from 0 to $\omega$ in adaptive steps that keep the effective sample size at least $N_p/2$. Each step uses systematic resampling followed by eight elliptical slice moves. Banks of $S = 64$ labels are drawn without replacement from the $N_p$ particles.
|
||||
Importance weights over 64 anchor-conditioned samples cannot move mass to warps that the anchor posterior rarely proposes, and in development runs that posterior did not contract to the true warp (Section~\ref{sec:exp:diag}). The second posterior therefore uses tempered sequential Monte Carlo. It starts from $N_p = 1024$ anchor-posterior samples and targets $p(u\mid \text{anchors})\, p(\mathbf s_w\mid u, \psi)^{\omega}$. The tempering exponent rises from 0 to $\omega$ in adaptive steps that keep the effective sample size at least $N_p/2$. Each step uses systematic resampling followed by eight elliptical slice moves. Banks of $S = 64$ labels are drawn without replacement from the $N_p$ particles. The bank size was fixed before the trial and not tuned. In an exploratory check made after all verdicts (Appendix~\ref{app:record}), nested banks of 256 and 1024 members drawn from the same particles had no wide cell in which their band RMSE was higher than that of the 64-member bank with a 95\% interval excluding 1, and were up to 2\% lower at $c = 1$ (6\% in one $c = 2$ cell), so $S = 64$ may have slightly understated the gain of the bank.
|
||||
|
||||
Before the trial the protocol fixed a stability criterion: the 95th percentile over $t$ of the difference between mean warps of independent runs must not exceed 0.5\,ms. On development data $N_p = 1024$ meets it at $c = 1$ in 4 of 4 cells at 10\,dB and in 3 of 4 at $-5$\,dB. At $c = 2$ the mean warp is unstable under every configuration we tried, and the posterior is often multimodal (Section~\ref{sec:exp:mech}). We summarize posterior width by $\sigpost = w_{90}/3.29$, where $w_{90}$ is the 90\% interval width of $\tau(t)$ averaged over the main window and the training wells. No labels are used to compute it.
|
||||
|
||||
|
||||
Reference in New Issue
Block a user