Rewrite the manuscript for outside readers; move formal results to App. A
Follow the style of the abstract in the remaining sections: results in words first, conditions up front, physical quantities instead of codes. A survey of Computers & Geosciences papers is recorded in docs/research/paper-style-survey.md. Replace repository codes with descriptive names in the text, tables and captions (10 dB, half-anchor, SMC mean, SMC bank, calibrated sonic); configs, outputs and code keep the codes, mapped in paper/README.md. Remove symbols that carried two meanings. Put Methods before Theory. Section 5 now states each result in words and Appendix A holds the formal statements with their proofs. Add tables of results and symbols, a table of failures with causes and lessons, a worked example in Sec. 6.6 and practical advice in Sec. 7. Move the protocol record and secondary results to a new Appendix C. The main text falls from about 20,600 to 15,400 words. Corrections from two rounds of review: state both pass rules (the bank claim has no margin), compare against the best deterministic tie, define calibration per function, drop the uninterpretable Berkson bounds at c = 2 from the table, define the SNR and noise, disclose the sigma_b mismatch, and correct 29-35% to 30-35%. Drop tab:p1 and fig:f3vol. No verdict, threshold or protocol changes. The figure scripts now draw the new names, but the figures still need regenerating on a machine with outputs/*/summary; red notes in the captions mark this. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -1,59 +1,35 @@
|
||||
\section{Field cases in detail}
|
||||
\label{app:field}
|
||||
|
||||
This appendix reports the two field tests in full. Section~\ref{sec:exp:scope} summarizes them and states what they can and cannot show. Both protocols were locked before their main runs; both gates failed, and nothing was changed after the test wells were scored.
|
||||
This appendix reports the two field tests in full. Section~\ref{sec:exp:scope} summarizes them and states what they can and cannot show. Both protocols were locked before their main runs (Appendix~\ref{app:record}), both pass rules failed, and nothing was changed after the test wells were scored.
|
||||
|
||||
\subsection{F3 field data (gate G-C)}
|
||||
\subsection{F3 field data}
|
||||
\label{sec:exp:f3}
|
||||
|
||||
\paragraph{Baselines.}
|
||||
Table~\ref{tab:p1} gives leave-one-well-out results for the baselines on F3. The label is $\mathrm{PHIE}_{\mathrm{DT}}$, and the reference is the marker-calibrated sonic of the test well. The test well contributes nothing to training, tie, hyperparameters or checkpoint selection. A depth--time trend fitted on the training wells (B0a) has the lowest RMSE. No learned model beats it in total RMSE, and its seismic-band PCC is negative. Seismic-attribute ridge regression (B0b) has the highest band PCC (0.24). Among networks, labels from the marker-calibrated tie (B3b) beat single-anchor sonic integration (B3a). With four wells these numbers are descriptive.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{F3 leave-one-well-out baselines (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, 600--1100\,ms). Macro over four wells; $\pm$: standard deviation over five seeds.}
|
||||
\label{tab:p1}
|
||||
\small
|
||||
\begin{tabular}{lcccc}
|
||||
\toprule
|
||||
Method & RMSE (p.u.) & PCC & band PCC & skill vs B0a \\
|
||||
\midrule
|
||||
B0a (trend) & \textbf{2.48} & 0.81 & $-0.13$ & 0.00 \\
|
||||
B0b ridge & 2.58 & \textbf{0.83} & \textbf{0.24} & $-0.09$ \\
|
||||
B0b random forest & $2.67 \pm 0.01$ & 0.79 & $-0.03$ & $-0.22$ \\
|
||||
B0b gradient boosting & 2.68 & 0.78 & 0.01 & $-0.20$ \\
|
||||
B1 (impedance inversion) & 3.60 & 0.44 & $-0.02$ & $-1.29$ \\
|
||||
B2 (composite loss) & $3.07 \pm 0.16$ & 0.52 & 0.15 & $-0.65$ \\
|
||||
B3a & $2.93 \pm 0.24$ & 0.62 & $-0.02$ & $-0.47$ \\
|
||||
B3b & $2.82 \pm 0.21$ & 0.68 & 0.15 & $-0.36$ \\
|
||||
\bottomrule
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{Protocol and deviations.}
|
||||
The field test was pre-registered in a third protocol. Its SHA-256 lock also covers the code, the input data and the software environment, and the scripts refuse to run if any of them changes. The lock file records that it was written one minute before the main run started (28 October 2026, 00:14 and 00:15 local time). The protocol was committed to version control and tagged only after the run, together with the results. The record that the lock preceded the run is therefore the time stamp inside the lock file, which is self-reported, not the version history. Before the lock we ran a timing pilot of the registration and a preflight of the classical baselines on F3. Neither computed a metric on a test well. No result on an F3 test well was used to design it. Two facts limit what the test can show. First, F3 is not an untouched field dataset. The same four wells gave the baselines of Table~\ref{tab:p1}, computed before the protocol was written, and they calibrated the synthetic benchmark (Section~\ref{sec:data:d2}). The field test is therefore a descriptive follow-up on wells we had already seen, not an independent replication. Second, the method under test comes from Experiment~2, whose protocol was itself designed after Experiment~1 had failed (Section~\ref{sec:exp:diag}). The field result therefore bears on the SMC variant only, and it leaves the verdict of Experiment~1 unchanged.
|
||||
\paragraph{No learned model beat a depth--time trend in total RMSE.}
|
||||
The label is $\mathrm{PHIE}_{\mathrm{DT}}$, the reference is the marker-calibrated sonic of the test well, and the test well contributes nothing to training, tie, hyperparameters or checkpoint selection. In Table~\ref{tab:f3all} the depth--time trend has the lowest RMSE (2.48\,p.u.), although its seismic-band PCC is negative, and ridge regression on seismic attributes has the highest band PCC (0.24). With four wells these numbers are descriptive.
|
||||
|
||||
\paragraph{Design.}
|
||||
We used nested leave-one-well-out validation. Each well is held out once as the outer test well. Within the three remaining wells, each is held out once as an inner validation well, and models are trained on the other two. Registration uses only the two training wells of each model: the warp-prior hyperparameters, the wavelet phase and the SMC posterior ($\sigma_a = 7$\,ms, $P = 1024$, $S = 64$) are all estimated from them. For each outer fold, method and seed, the iteration budget is chosen from $\{125, 250, 500, 1000, 2000\}$ by total validation MSE averaged over the three inner wells, with ties going to the smaller budget. This replaces the selection on development realizations used in the synthetic experiments (Section~\ref{sec:method:train}). The prediction at the outer well is a Gaussian with the mean and variance of the equally weighted mixture of 15 members (three inner models $\times$ five seeds). Nothing is refitted on the outer well, and its labels enter no choice. The primary label is $\mathrm{PHIE}_{\mathrm{DT}}$, and the reference is the marker-calibrated sonic of the test well, as in Table~\ref{tab:p1}.
|
||||
We used nested leave-one-well-out validation. Each well is held out once as the outer test well. Within the three remaining wells, each is held out once as an inner validation well, and models are trained on the other two. Registration uses only the two training wells of each model: the warp-prior hyperparameters, the wavelet phase and the SMC posterior ($\sigma_a = 7$\,ms, $N_p = 1024$, $S = 64$) are all estimated from them. For each outer fold, method and seed, the iteration budget is chosen from $\{125, 250, 500, 1000, 2000\}$ by total validation MSE averaged over the three inner wells, with ties going to the smaller budget. The prediction at the outer well is a Gaussian with the mean and variance of the equally weighted mixture of 15 members (three inner models $\times$ five seeds). Nothing is refitted on the outer well, and its labels enter no choice.
|
||||
|
||||
Gate G-C required two conditions for \mRML{} in this configuration. (i) \emph{Direction}: lower band RMSE than the point tie chosen for that outer fold among B3b, B3c and B3c-R, by inner-validation MSE averaged over seeds, at no fewer than three of the four outer wells. Any reduction counts, so this rule is weaker than the 0.90 ratio of the synthetic experiments. (ii) \emph{Coverage}: macro coverage of the central 80\% and 90\% intervals within $\pm 0.05$ of nominal, that is, in $[0.75, 0.85]$ and $[0.85, 0.95]$. Coverage is the fraction of time samples in the window that fall inside the interval. These samples are strongly correlated, so coverage is a description, not a test. The protocol also states that better accuracy cannot compensate for failed coverage. Before the run we had recorded that the coverage condition would probably fail, because every ensemble had under-covered in the synthetic experiments. We kept the threshold.
|
||||
The pass rule had two conditions for the \mRML{}. (i) \emph{Direction}: lower band RMSE than the deterministic tie chosen for that outer fold among the calibrated sonic, the correlation tie and the phase-estimated correlation, by inner-validation MSE averaged over seeds, at no fewer than three of the four outer wells. Any reduction counts, so this rule is weaker than the 0.90 ratio of the synthetic experiments. (ii) \emph{Coverage}: macro coverage of the central 80\% and 90\% intervals within $\pm 0.05$ of nominal, that is, in $[0.75, 0.85]$ and $[0.85, 0.95]$. These time samples are strongly correlated, so coverage is a description, not a test. Better accuracy cannot compensate for failed coverage. Before the run we had recorded that the coverage condition would probably fail, because every ensemble had under-covered in the synthetic experiments, and we kept the threshold.
|
||||
|
||||
\paragraph{Result: the gate failed.}
|
||||
Both conditions failed (Table~\ref{tab:f3gc}). Inner validation chose B3c-R as the competitor at all four outer wells. \mRML{} had lower band RMSE only at F03-4, by 1.9\%. At F02-1 and F03-2 it was 0.8\% and 0.02\% worse, and at F06-1 it was 7.0\% worse. Its macro band RMSE was 1.272\,p.u., against 1.256\,p.u.\ for B3c-R. Macro coverage was 0.524 for the 80\% intervals and 0.609 for the 90\% intervals, far below the lower limits of 0.75 and 0.85. At F03-2 and F03-4 the 80\% and 90\% intervals covered 0.75 and 0.80 of the samples, just below and well below nominal. At F02-1 and F06-1 they covered 0.22--0.38 and 0.33--0.50. At these two wells most of the error lay below 6\,Hz: the low-band RMSE was 4.31 and 3.64\,p.u., out of a total RMSE of 4.56 and 3.82\,p.u., while the mean predicted standard deviation was 1.05 and 1.27\,p.u. Seed by seed (three-member ensembles), \mRML{} beat B3c-R at one to three of the four wells. The macro band RMSE of each method varied between seeds by up to 0.13\,p.u.\ (\mRML: 1.28--1.41\,p.u.; B3c-R: 1.29--1.41\,p.u.), eight times the gap between the combined ensembles. The competitor was not changed after the test wells were scored, and the intervals were not widened. Under this protocol, training on the SMC bank gave no band-RMSE gain over the best point tie on F3, and its predictive intervals were much too narrow. We make no claim of improvement on field data and no claim of calibrated uncertainty.
|
||||
\paragraph{Both conditions failed.}
|
||||
Inner validation chose the phase-estimated correlation as the competitor at all four outer wells (Table~\ref{tab:f3gc}). The \mRML{} had lower band RMSE only at F03-4, by 1.9\%. At F02-1 and F03-2 it was 0.8\% and 0.02\% worse, and at F06-1 it was 7.0\% worse. Its macro band RMSE was 1.272\,p.u., against 1.256\,p.u.\ for the competitor. Macro coverage was 0.524 for the 80\% intervals and 0.609 for the 90\% intervals. At F03-2 and F03-4 the 80\% and 90\% intervals covered 0.75 and 0.80 of the samples. At F02-1 and F06-1 they covered 0.22--0.38 and 0.33--0.50. At these two wells most of the error lay below 6\,Hz: the low-band RMSE was 4.31 and 3.64\,p.u., out of a total RMSE of 4.56 and 3.82\,p.u., while the mean predicted standard deviation was 1.05 and 1.27\,p.u. Seed by seed (three-member ensembles), the \mRML{} beat the competitor at one to three of the four wells, and the macro band RMSE of each method varied between seeds by up to 0.13\,p.u.\ (\mRML: 1.28--1.41\,p.u.; competitor: 1.29--1.41\,p.u.), eight times the gap between the combined ensembles.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{Gate G-C on F3 (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, 600--1100\,ms, $\sigma_a = 7$\,ms, 15-member ensemble). Competitor: the point tie chosen by inner validation. Ratio: band RMSE of \mRML{} divided by that of the competitor; at F03-2 it is 1.0002. Coverage: fraction of the 126 time samples inside the central interval of \mRML; at F03-2 and F03-4 the same counts (94 and 101 samples) occur by coincidence.}
|
||||
\caption{F3 pass rule (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, 600--1100\,ms, $\sigma_a = 7$\,ms, 15-member ensemble). Competitor: the deterministic tie chosen by inner validation. Ratio: band RMSE of \mRML{} divided by that of the competitor; at F03-2 it is 1.0002. Coverage: fraction of the 126 time samples inside the central interval of \mRML; at F03-2 and F03-4 the same counts (94 and 101 samples) occur by coincidence.}
|
||||
\label{tab:f3gc}
|
||||
\small
|
||||
\begin{tabular}{lccccc}
|
||||
\toprule
|
||||
Outer well & competitor & ratio & improved & cov$_{80}$ & cov$_{90}$ \\
|
||||
\midrule
|
||||
F02-1 & B3c-R & 1.008 & no & 0.222 & 0.333 \\
|
||||
F03-2 & B3c-R & 1.000 & no & 0.746 & 0.802 \\
|
||||
F03-4 & B3c-R & 0.981 & yes & 0.746 & 0.802 \\
|
||||
F06-1 & B3c-R & 1.070 & no & 0.381 & 0.500 \\
|
||||
F02-1 & Phase-est.\ corr. & 1.008 & no & 0.222 & 0.333 \\
|
||||
F03-2 & Phase-est.\ corr. & 1.000 & no & 0.746 & 0.802 \\
|
||||
F03-4 & Phase-est.\ corr. & 0.981 & yes & 0.746 & 0.802 \\
|
||||
F06-1 & Phase-est.\ corr. & 1.070 & no & 0.381 & 0.500 \\
|
||||
\midrule
|
||||
Macro & & & 1/4 & 0.524 & 0.609 \\
|
||||
Required & & & $\ge 3/4$ & $[0.75, 0.85]$ & $[0.85, 0.95]$ \\
|
||||
@@ -61,8 +37,8 @@ Required & & & $\ge 3/4$ & $[0.75, 0.85]$ & $[0.85, 0.95]$ \\
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{Relation to Experiment~2.}
|
||||
In the synthetic benchmark, \mRML{} beat the best point tie in all three full-anchor regimes, under a stricter rule (Section~\ref{sec:exp:p2r}). On F3 this direction held at one well of four. The field test does not show why, and we tested no explanation. Two features of F3 limit what it can detect. First, the synthetic gains required a correctly specified $\sigma_a$ (Table~\ref{tab:sigmaa}). On F3, $\sigma_a$ is not identified: 7\,ms comes from the marker--horizon spread (Section~\ref{sec:data:f3}), not from an independent measurement. Second, the reference is itself a point tie, the marker-calibrated sonic of B3b. Its registration error adds to the band RMSE of every method, which pulls ratios towards one, and it favours methods whose label errors resemble its own. Neither feature changes the verdict.
|
||||
\paragraph{Two features of F3 limit what the test can detect.}
|
||||
In the synthetic benchmark the \mRML{} beat the best deterministic tie in all three full-anchor settings under a stricter rule, while on F3 this direction held at one well of four. The field test does not show why, and we tested no explanation. First, the synthetic gains required a correctly specified $\sigma_a$ (Table~\ref{tab:sigmaa}), and on F3 $\sigma_a$ is not identified: 7\,ms comes from the marker--horizon spread, not from an independent measurement. Second, the reference is itself a point tie, the marker-calibrated sonic. Its registration error adds to the band RMSE of every method, which pulls ratios towards one, and it favours methods whose label errors resemble its own.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
@@ -73,26 +49,26 @@ In the synthetic benchmark, \mRML{} beat the best point tie in all three full-an
|
||||
\toprule
|
||||
Method & band RMSE & band PCC & RMSE & PCC & cov$_{80}$ & cov$_{90}$ \\
|
||||
\midrule
|
||||
B0a (trend) & 1.239 & $-0.13$ & \textbf{2.48} & 0.81 & -- & -- \\
|
||||
B0b ridge & 1.271 & \textbf{0.24} & 2.58 & \textbf{0.83} & -- & -- \\
|
||||
B0b random forest & 1.511 & $-0.03$ & 2.67 & 0.79 & -- & -- \\
|
||||
B0b gradient boosting & 1.537 & 0.01 & 2.68 & 0.78 & -- & -- \\
|
||||
B1 (impedance inversion) & 3.090 & $-0.02$ & 3.60 & 0.44 & -- & -- \\
|
||||
B2 (composite loss) & 1.252 & 0.19 & 3.09 & 0.53 & 0.38 & 0.44 \\
|
||||
Depth--time trend & 1.239 & $-0.13$ & \textbf{2.48} & 0.81 & -- & -- \\
|
||||
Ridge & 1.271 & \textbf{0.24} & 2.58 & \textbf{0.83} & -- & -- \\
|
||||
Random forest & 1.511 & $-0.03$ & 2.67 & 0.79 & -- & -- \\
|
||||
Gradient boosting & 1.537 & 0.01 & 2.68 & 0.78 & -- & -- \\
|
||||
Impedance inversion & 3.090 & $-0.02$ & 3.60 & 0.44 & -- & -- \\
|
||||
Composite loss & 1.252 & 0.19 & 3.09 & 0.53 & 0.38 & 0.44 \\
|
||||
\midrule
|
||||
B3a & 1.348 & $-0.01$ & 3.13 & 0.44 & 0.47 & 0.57 \\
|
||||
B3b & 1.284 & 0.16 & 3.07 & 0.52 & 0.50 & 0.59 \\
|
||||
B3c & 1.282 & 0.20 & 3.14 & 0.45 & 0.48 & 0.58 \\
|
||||
B3c-R & 1.256 & 0.20 & 2.98 & 0.59 & 0.51 & 0.59 \\
|
||||
B3d & 1.266 & 0.16 & 3.05 & 0.52 & 0.51 & 0.60 \\
|
||||
Sonic tie & 1.348 & $-0.01$ & 3.13 & 0.44 & 0.47 & 0.57 \\
|
||||
Calibrated sonic & 1.284 & 0.16 & 3.07 & 0.52 & 0.50 & 0.59 \\
|
||||
Correlation tie & 1.282 & 0.20 & 3.14 & 0.45 & 0.48 & 0.58 \\
|
||||
Phase-est.\ corr. & 1.256 & 0.20 & 2.98 & 0.59 & 0.51 & 0.59 \\
|
||||
Anchor mean & 1.266 & 0.16 & 3.05 & 0.52 & 0.51 & 0.60 \\
|
||||
\mPM & 1.275 & 0.15 & 3.00 & 0.57 & 0.47 & 0.57 \\
|
||||
\midrule
|
||||
B4a & 1.232 & 0.18 & 3.24 & 0.39 & 0.49 & 0.58 \\
|
||||
B4b & \textbf{1.211} & 0.22 & 3.17 & 0.43 & 0.49 & 0.60 \\
|
||||
B4c & 1.237 & 0.22 & 3.12 & 0.57 & 0.42 & 0.52 \\
|
||||
B4d & 1.254 & 0.21 & 3.14 & 0.57 & 0.47 & 0.58 \\
|
||||
Hard-min shift & 1.232 & 0.18 & 3.24 & 0.39 & 0.49 & 0.58 \\
|
||||
Soft-min shift & \textbf{1.211} & 0.22 & 3.17 & 0.43 & 0.49 & 0.60 \\
|
||||
Soft-DTW & 1.237 & 0.22 & 3.12 & 0.57 & 0.42 & 0.52 \\
|
||||
DILATE & 1.254 & 0.21 & 3.14 & 0.57 & 0.47 & 0.58 \\
|
||||
\midrule
|
||||
M1 & 1.286 & 0.13 & 3.14 & 0.49 & 0.50 & 0.58 \\
|
||||
Anchor bank & 1.286 & 0.13 & 3.14 & 0.49 & 0.50 & 0.58 \\
|
||||
\mRML & 1.272 & 0.18 & 3.12 & 0.49 & \textbf{0.52} & \textbf{0.61} \\
|
||||
\midrule
|
||||
No band content & 1.224 & -- & -- & -- & -- & -- \\
|
||||
@@ -100,26 +76,26 @@ No band content & 1.224 & -- & -- & -- & -- & -- \\
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{All methods.}
|
||||
Table~\ref{tab:f3all} lists every method under the nested design. B0a, B0b and B1 use the code of Table~\ref{tab:p1} and reproduce its values. The networks have higher total RMSE than in Table~\ref{tab:p1} (B3b: 3.07 against 2.82\,p.u.); here each model is trained on two wells rather than three, and its budget is chosen by inner validation. Only B4b had a lower macro band RMSE than a prediction with no seismic-band content (1.211 against 1.224\,p.u.). B0a, which has almost no band content, came within 1.3\% of that value, and every point tie, \mPM{} and \mRML{} lay above it. Band PCC did not exceed 0.22 for any network in Table~\ref{tab:f3all}. On F3 the networks therefore predicted little of the seismic-band variation of the label, and G-C compared methods whose band errors were nearly the same size: without B3a, the other 12 networks span 1.211--1.286\,p.u. The ranking also differs from the synthetic experiments. All four anchor-free losses, B4a--B4d, had lower macro band RMSE than every point tie, \mPM{} and \mRML, by 0.002--0.14\,p.u.\ (up to 0.06 relative to \mPM{} and \mRML). Every probabilistic method of Table~\ref{tab:f3all} under-covered. Macro coverage was 0.38--0.52 for the 80\% intervals and 0.44--0.61 for the 90\% intervals, and \mRML{} had the highest values of both.
|
||||
\paragraph{The networks predicted little of the seismic band.}
|
||||
Table~\ref{tab:f3all} lists every method under the nested design. The networks have higher total RMSE than in a simpler leave-one-well-out design with three training wells (calibrated sonic: 3.07 against 2.82\,p.u., not tabulated), because each model here is trained on two wells and its budget is chosen by inner validation. Only the soft-min shift had a lower macro band RMSE than a prediction with no seismic-band content (1.211 against 1.224\,p.u.). The depth--time trend, which has almost no band content, came within 1.3\% of that value, and every deterministic tie, the \mPM{} and the \mRML{} lay above it. Band PCC did not exceed 0.22 for any network. The test therefore compared methods whose band errors were nearly the same size: without the sonic tie, the other 12 networks span 1.211--1.286\,p.u. The ranking also differs from the synthetic experiments. All four anchor-free losses had lower macro band RMSE than every deterministic tie, the \mPM{} and the \mRML{}, by 0.002--0.14\,p.u.\ (up to 0.06 relative to the \mPM{} and \mRML{}). Every probabilistic method under-covered: macro coverage was 0.38--0.52 for the 80\% intervals and 0.44--0.61 for the 90\% intervals, and the \mRML{} had the highest values of both.
|
||||
|
||||
\paragraph{Same posterior, $\sigma_a$ and scoring reference.}
|
||||
The protocol prescribes four further comparisons. None can replace a G-C condition, and none was used to choose a result. Table~\ref{tab:f3sens} gives the per-well ratios. In no row did the coverage condition hold.
|
||||
(a) Against \mPM, which is trained on the mean of the same SMC posterior, \mRML{} had lower band RMSE at two wells (F02-1 and F03-4) and higher band RMSE at F03-2, by 9.3\%, and at F06-1, by 1.2\%. Its macro band RMSE was 0.003\,p.u.\ lower.
|
||||
(b) With $\sigma_a = 3.5$ or 14\,ms, B3c-R, \mPM{} and \mRML{} were registered and trained again, and \mRML{} was compared with B3c-R at the same $\sigma_a$. It had lower band RMSE at one and two of the four wells, and the wells that improved were not the same in the three arms. Macro coverage was 0.47--0.48 and 0.57--0.59.
|
||||
(c) When the test well is scored against the OpendTect time--depth model instead of the marker-calibrated sonic, \mRML{} again improved only at F03-4. We also scored each method against 64 warps of the test well, drawn from an anchor-only posterior whose prior was fitted on the other three wells. The 5--95\% range of band RMSE over these references was 0.06--0.15\,p.u.\ wide for \mRML{} and for B3c-R, and the ranges of the two methods overlapped at F02-1, F03-2 and F03-4. At F06-1 they did not overlap (\mRML: 1.13--1.18\,p.u.; B3c-R: 1.04--1.11\,p.u.).
|
||||
(d) Moving the band cutoff to 5 or 8\,Hz changed no ratio by more than 0.011, but at 8\,Hz \mRML{} also improved at F03-2 (2/4). With the original PHIE label, \mRML{} improved at three wells, but coverage was lower (0.45 and 0.50). In the window the two labels differ by an RMS of 3.2\,p.u.\ at F02-1 and by less than 0.02\,p.u.\ at the other wells. F02-1 is a training well in three of the four outer folds, and the ratios at those three test wells moved by up to 0.13. This shows how much a ratio near one depends on the label of a single training well. The gate is defined on $\mathrm{PHIE}_{\mathrm{DT}}$, and this row does not change its result.
|
||||
\paragraph{Sensitivity analyses did not change the outcome.}
|
||||
The protocol prescribes four further comparisons, none of which can replace a condition of the pass rule (Table~\ref{tab:f3sens}). In no row did the coverage condition hold.
|
||||
(a) Against the \mPM{}, trained on the mean of the same posterior, the \mRML{} had lower band RMSE at two wells (F02-1 and F03-4) and higher band RMSE at F03-2, by 9.3\%, and at F06-1, by 1.2\%. Its macro band RMSE was 0.003\,p.u.\ lower.
|
||||
(b) With $\sigma_a = 3.5$ or 14\,ms, the phase-estimated correlation, the \mPM{} and the \mRML{} were registered and trained again, and the \mRML{} had lower band RMSE than that competitor at one and two of the four wells; the wells that improved were not the same in the three arms. Macro coverage was 0.47--0.48 and 0.57--0.59.
|
||||
(c) When the test well is scored against the OpendTect time--depth model instead, the \mRML{} again improved only at F03-4. We also scored each method against 64 warps of the test well, drawn from an anchor-only posterior whose prior was fitted on the other three wells. The 5--95\% range of band RMSE over these references was 0.06--0.15\,p.u.\ wide for both methods, and the ranges overlapped at F02-1, F03-2 and F03-4. At F06-1 they did not (\mRML: 1.13--1.18\,p.u.; competitor: 1.04--1.11\,p.u.).
|
||||
(d) Moving the band cutoff to 5 or 8\,Hz changed no ratio by more than 0.011, but at 8\,Hz the \mRML{} also improved at F03-2 (2/4). With the original PHIE label, it improved at three wells, but coverage was lower (0.45 and 0.50). The two labels differ by an RMS of 3.2\,p.u.\ at F02-1 and by less than 0.02\,p.u.\ at the other wells. F02-1 is a training well in three of the four outer folds, and the ratios at those three test wells moved by up to 0.13, which shows how much a ratio near one depends on the label of a single training well.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{F3 sensitivity of the G-C comparison (combined ensembles, descriptive). Ratio: band RMSE of \mRML{} divided by that of B3c-R, except in the second row (\mRML{} divided by \mPM). In the $\sigma_a$ rows both methods use the stated $\sigma_a$. Coverage is that of \mRML{} and does not depend on $f_c$ (--). At F03-2 with $f_c = 5$\,Hz the ratio is 1.00002.}
|
||||
\caption{Sensitivity of the F3 comparison (combined ensembles, descriptive). Ratio: band RMSE of \mRML{} divided by that of Phase-est.\ corr., except in the second row (\mRML{} divided by \mPM). In the $\sigma_a$ rows both methods use the stated $\sigma_a$. Coverage is that of \mRML{} and does not depend on $f_c$ (--). At F03-2 with $f_c = 5$\,Hz the ratio is 1.00002.}
|
||||
\label{tab:f3sens}
|
||||
\small
|
||||
\begin{tabular}{lccccccc}
|
||||
\toprule
|
||||
Variant & F02-1 & F03-2 & F03-4 & F06-1 & improved & cov$_{80}$ & cov$_{90}$ \\
|
||||
\midrule
|
||||
Registered (Table~\ref{tab:f3gc}) & 1.008 & 1.000 & 0.981 & 1.070 & 1/4 & 0.52 & 0.61 \\
|
||||
Pre-registered (Table~\ref{tab:f3gc}) & 1.008 & 1.000 & 0.981 & 1.070 & 1/4 & 0.52 & 0.61 \\
|
||||
\mRML{} / \mPM & 0.970 & 1.093 & 0.941 & 1.012 & 2/4 & -- & -- \\
|
||||
$\sigma_a = 3.5$\,ms & 1.010 & 0.939 & 1.003 & 1.034 & 1/4 & 0.48 & 0.59 \\
|
||||
$\sigma_a = 14$\,ms & 0.989 & 0.959 & 1.020 & 1.035 & 2/4 & 0.47 & 0.57 \\
|
||||
@@ -131,69 +107,66 @@ PHIE label & 0.992 & 0.911 & 1.025 & 0.943 & 3/4 & 0.45 & 0.50 \\
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{Posterior width and anchors.}
|
||||
At $\sigma_a = 7$\,ms, $\sigpost$ of the SMC posterior ranged from 1.7 to 3.6\,ms over the 12 training wells of the six training pairs (median 2.8\,ms). Seven of the 12 values lay in the range of 2.5--3.4\,ms estimated before the run from all four wells. By the rule of Experiment~2 every pair is therefore wide ($\sigpost \ge 1.5$\,ms), the regime in which RML helped at $N = 16$. Each F3 model, however, is trained on two wells, and \mRML{} beat \mPM{} at two of the four outer wells (Table~\ref{tab:f3sens}). The width followed $\sigma_a$: it was 1.2--2.3\,ms at $\sigma_a = 3.5$\,ms and 1.9--6.2\,ms at 14\,ms. Without anchors it was 17--38\,ms at F02-1, F03-2 and F03-4, and 1.4--2.0\,ms at F06-1. The wavelet phase was poorly identified. The six phases estimated at $\sigma_a = 7$\,ms spread over an arc of 214$^\circ$. Over the phases evaluated for each pair, a window 90--120$^\circ$ wide, the summed log evidence of the two wells changed by only 1.0--5.0\,nats.
|
||||
\paragraph{The posterior was wide, followed the anchor uncertainty and left the phase poorly identified.}
|
||||
At $\sigma_a = 7$\,ms, $\sigpost$ ranged from 1.7 to 3.6\,ms over the 12 training wells of the six training pairs (median 2.8\,ms), and seven of the 12 values lay in the range of 2.5--3.4\,ms estimated before the run from all four wells. Every pair is therefore wide by the rule of Experiment~2. The width followed $\sigma_a$: it was 1.2--2.3\,ms at $\sigma_a = 3.5$\,ms and 1.9--6.2\,ms at 14\,ms. Without anchors it was 17--38\,ms at F02-1, F03-2 and F03-4, and 1.4--2.0\,ms at F06-1. The six phases estimated at $\sigma_a = 7$\,ms spread over an arc of 214$^\circ$. Over the phases evaluated for each pair, a window 90--120$^\circ$ wide, the summed log evidence of the two wells changed by only 1.0--5.0\,nats.
|
||||
|
||||
Leave-one-anchor-out $z$-scores test the anchor prior on the outer wells. For each well, a linearized Gaussian process conditioned on the anchors alone, with hyperparameters fitted on the other three wells and pick noise $\sigma_a = 7$\,ms, predicts each anchor time from the remaining anchors of that well. Of 62 held-out anchors, 61 lay inside the 90\% interval. The mean $z^2$ was 0.21 (per well: 0.20, 0.01, 0.01 and 0.59), against an expected value of 1. The anchor prior is therefore too wide rather than too narrow, the same direction as the type-II estimate of $\sigma_a$ (0.4\,ms, Section~\ref{sec:method:prior}) and the opposite direction to the under-coverage of porosity. This check does not test the calibration of the SMC posterior, which also depends on the seismic likelihood and the wavelet phase.
|
||||
A second leave-one-anchor-out test, different from that of Section~\ref{sec:method:prior}, checks the anchor prior on the outer wells. For each well, a linearized Gaussian process conditioned on the anchors alone, with hyperparameters fitted on the other three wells and pick noise $\sigma_a = 7$\,ms, predicts each anchor time from the remaining anchors of that well. Of 62 held-out anchors, 61 lay inside the 90\% interval, and the mean $z^2$ was 0.21 (per well: 0.20, 0.01, 0.01 and 0.59), against an expected value of 1. The anchor prior is therefore too wide rather than too narrow, the same direction as the type-II estimate of $\sigma_a$ (0.4\,ms) and the opposite direction to the under-coverage of porosity. This check does not test the calibration of the SMC posterior, which also depends on the seismic likelihood and the wavelet phase.
|
||||
|
||||
\paragraph{Ablations (descriptive).}
|
||||
The protocol lists twelve ablations on $\mathrm{PHIE}_{\mathrm{DT}}$, eleven of \mRML{} and one of \mPM{} (Table~\ref{tab:f3abl}). They were scored like every other method, but none enters G-C. M2-anchor-only trains on the 64 anchor-only warps of M1 with the same weights, so it reproduces M1 exactly. Nine of the other eleven variants had lower macro band RMSE than \mRML. The variants spanned 1.242--1.309\,p.u., about four times the gap of 0.016\,p.u.\ between \mRML{} and B3c-R. Bank size had no consistent effect: with 1, 8, 64 and 256 SMC labels, band RMSE was 1.273, 1.256, 1.272 and 1.257\,p.u. A convolutional backbone without the GRU lowered band RMSE by about 2\% for both \mRML{} (M2-TCN) and \mPM{} (B3d-Sa-TCN), so it did not change their order. Removing the anchors (M2-no-anchors) lowered band RMSE to 1.247\,p.u.\ but gave the highest total RMSE of the variants (3.23\,p.u.). M2-fixed-sigma was the only variant with coverage close to nominal (0.87 and 0.92), and this is not calibration. Its predicted standard deviation is fixed at the standard deviation of the training labels, which gave 2.9--4.3\,p.u.\ after mixing, against 1.0--2.1\,p.u.\ for \mRML. Its 80\% intervals covered every sample at F03-2 and F03-4 and 0.74 and 0.73 of the samples at F02-1 and F06-1. The macro value is an average of these, not evidence of correct width. M2-LFM adds the low-pass mean label of the training wells as an input channel. It had the lowest total RMSE of any network (2.62\,p.u., against 2.48\,p.u.\ for B0a) and the highest band RMSE of the variants (1.309\,p.u.). Its gain lies below $f_c$, where the gate does not score.
|
||||
\paragraph{Ablations moved the band score by more than the gap under test.}
|
||||
The protocol lists twelve ablations (Table~\ref{tab:f3abl}), scored like every other method. The anchor-only variant trains on the 64 anchor-only warps of the anchor bank with the same weights, so it reproduces that method exactly. Nine of the other eleven variants had lower macro band RMSE than the \mRML{}. The variants spanned 1.242--1.309\,p.u., about four times the gap of 0.016\,p.u.\ between the \mRML{} and its competitor. Bank size had no consistent effect: with 1, 8, 64 and 256 SMC labels, band RMSE was 1.273, 1.256, 1.272 and 1.257\,p.u. A convolutional backbone without the GRU lowered band RMSE by about 2\% for both the \mRML{} and the \mPM{}, so it did not change their order. Removing the anchors lowered band RMSE to 1.247\,p.u.\ but gave the highest total RMSE of the variants (3.23\,p.u.). The fixed-$\sigma$ variant was the only one with coverage close to nominal (0.87 and 0.92), and this is not calibration. Its predicted standard deviation is fixed at that of the training labels, which gave 2.9--4.3\,p.u.\ after mixing, against 1.0--2.1\,p.u.\ for the \mRML{}. Its 80\% intervals covered every sample at F03-2 and F03-4 and 0.74 and 0.73 of the samples at F02-1 and F06-1, so the macro value is an average of these, not evidence of correct width. Adding the low-pass mean label of the training wells as an input gave the lowest total RMSE of any network (2.62\,p.u., against 2.48\,p.u.\ for the depth--time trend) and the highest band RMSE of the variants (1.309\,p.u.). Its gain lies below $f_c$, where the pass rule does not score.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{Ablations of \mRML{} on F3 (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, $\sigma_a = 7$\,ms, combined ensembles; descriptive). Macro over four wells; RMSE in p.u. M2-anchor-only is identical to M1 by construction.}
|
||||
\caption{Ablations of \mRML{} on F3 (label $\mathrm{PHIE}_{\mathrm{DT}}$, marker-calibrated reference, $\sigma_a = 7$\,ms, combined ensembles; descriptive). Macro over four wells; RMSE in p.u. The anchor-only variant is identical to the anchor bank by construction.}
|
||||
\label{tab:f3abl}
|
||||
\small
|
||||
\begin{tabular}{l>{\raggedright\arraybackslash}p{6.4cm}cccc}
|
||||
\begin{tabular}{l>{\raggedright\arraybackslash}p{5.4cm}cccc}
|
||||
\toprule
|
||||
Variant & change from \mRML & band RMSE & RMSE & cov$_{80}$ & cov$_{90}$ \\
|
||||
\midrule
|
||||
\mRML & registered method: 64 SMC labels, CNN--GRU backbone & 1.272 & 3.12 & 0.52 & 0.61 \\
|
||||
\mRML & pre-registered method: 64 SMC labels, CNN--GRU backbone & 1.272 & 3.12 & 0.52 & 0.61 \\
|
||||
\midrule
|
||||
M2-anchor-only & 64 anchor-only warps (= M1) & 1.286 & 3.14 & 0.50 & 0.58 \\
|
||||
M2-no-anchors & no anchor conditioning; prior hyperparameters at the pre-declared medians & 1.247 & 3.23 & 0.48 & 0.56 \\
|
||||
M2-bulk & sonic integration plus a constant shift, resampled by the seismic likelihood & 1.251 & 3.16 & 0.49 & 0.58 \\
|
||||
M2-lambda1 & $\lambda = 1$ instead of $1/\tau_c$ & 1.257 & 3.09 & 0.52 & 0.62 \\
|
||||
M2-S1 & 1 SMC label & 1.273 & 3.08 & 0.48 & 0.57 \\
|
||||
M2-S8 & 8 SMC labels & 1.256 & 3.11 & 0.48 & 0.59 \\
|
||||
M2-S256 & 256 SMC labels & 1.257 & 3.10 & 0.50 & 0.58 \\
|
||||
M2-fixed-sigma & $\sigma$ fixed at the training-label standard deviation & 1.242 & 3.08 & 0.87 & 0.92 \\
|
||||
M2-legacy-loss & composite loss of B2 on the bank mean added & 1.243 & 3.11 & 0.41 & 0.49 \\
|
||||
M2-TCN & four dilated convolutions, no GRU & 1.245 & 3.10 & 0.38 & 0.48 \\
|
||||
B3d-Sa-TCN & \mPM{} with the M2-TCN backbone & 1.250 & 3.13 & 0.40 & 0.49 \\
|
||||
M2-LFM & low-pass mean training label as an extra input & 1.309 & 2.62 & 0.40 & 0.50 \\
|
||||
Anchor only & 64 anchor-only warps (= anchor bank) & 1.286 & 3.14 & 0.50 & 0.58 \\
|
||||
No anchors & no anchor conditioning; prior hyperparameters at the pre-declared medians & 1.247 & 3.23 & 0.48 & 0.56 \\
|
||||
Bulk shift only & sonic integration plus a constant shift, resampled by the seismic likelihood & 1.251 & 3.16 & 0.49 & 0.58 \\
|
||||
$\lambda = 1$ & $\lambda = 1$ instead of $1/\tau_c$ & 1.257 & 3.09 & 0.52 & 0.62 \\
|
||||
1 label & 1 SMC label & 1.273 & 3.08 & 0.48 & 0.57 \\
|
||||
8 labels & 8 SMC labels & 1.256 & 3.11 & 0.48 & 0.59 \\
|
||||
256 labels & 256 SMC labels & 1.257 & 3.10 & 0.50 & 0.58 \\
|
||||
Fixed $\sigma$ & $\sigma$ fixed at the training-label standard deviation & 1.242 & 3.08 & 0.87 & 0.92 \\
|
||||
Composite loss added & composite loss on the bank mean added & 1.243 & 3.11 & 0.41 & 0.49 \\
|
||||
TCN & four dilated convolutions, no GRU & 1.245 & 3.10 & 0.38 & 0.48 \\
|
||||
\mPM{}, TCN & \mPM{} with the TCN backbone & 1.250 & 3.13 & 0.40 & 0.49 \\
|
||||
Low-frequency input & low-pass mean training label as an extra input & 1.309 & 2.62 & 0.40 & 0.50 \\
|
||||
\bottomrule
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{Predicted volume (descriptive).}
|
||||
A deployment ensemble of \mRML{} predicted all 649 interior inlines of the survey (Fig.~\ref{fig:f3vol}). It has 20 members: four three-well training sets $\times$ five seeds. The map shows sonic-derived porosity and its ensemble standard deviation. Away from the wells there is no ground truth, and three of the four training sets include any given well, so the prediction at a well is not blind. The same kind of ensemble under-covered at the outer wells, so its standard deviation is not a calibrated error bar. Over the $649 \times 949$ interior traces and the 600--1100\,ms window, the median of the predicted mean was 29.6\,p.u.\ (5--95\% of samples: 27.9--31.5\,p.u.). The median standard deviation was 1.3\,p.u.\ (5--95\%: 0.8--2.5\,p.u.). It was larger above 700\,ms (median 2.0\,p.u.) than below (1.2\,p.u.). Even the median standard deviation is less than half the total RMSE of \mRML{} at the outer wells (3.12\,p.u.).
|
||||
\paragraph{Predicted volume.}
|
||||
A deployment ensemble of the \mRML{} (four three-well training sets $\times$ five seeds) predicted all 649 interior inlines of the survey. The volume is archived as a descriptive product. It is not blind at the wells, and its standard deviation is not a calibrated error bar.
|
||||
|
||||
\begin{figure}[t]
|
||||
\centering
|
||||
\includegraphics[width=\linewidth]{f3_volume.pdf}
|
||||
\caption{Descriptive prediction of sonic-derived porosity ($\mathrm{PHIE}_{\mathrm{DT}}$) on F3 inline 442, through F03-4 (dashed line): (a) mean and (b) standard deviation of the 20-member \mRML{} deployment ensemble. Colour limits: 1st--99th percentile of the section for (a), 0 to the 99th percentile for (b). Three of the four training sets include F03-4, so the prediction at the well is not blind. Intervals from this kind of ensemble under-covered at the outer wells (Table~\ref{tab:f3gc}).}
|
||||
\label{fig:f3vol}
|
||||
\end{figure}
|
||||
|
||||
\paragraph{Execution.}
|
||||
The run stopped once, after 132 of 649 volume inlines, when the operating system refused to replace a progress-display file. By then the gate had been computed. Only volume inference was resumed, with the locked code and models. Registration, training and scoring were not rerun, and the 132 inlines written before the stop were verified to be unchanged.
|
||||
|
||||
\subsection{Volve field data (gate G-D)}
|
||||
\subsection{Volve field data}
|
||||
\label{sec:exp:volve}
|
||||
|
||||
\paragraph{Protocol and deviations.}
|
||||
The Volve test was designed on 28 October 2026, after the F3 gate had failed and before any porosity metric, prediction or training run on Volve. Its protocol follows the F3 protocol, and the lock again covers the code, the input data and the software environment. The lock file records that it was written at 01:17:42 UTC on 29 October 2026, before the primary run started; as on F3, this record is the time stamp inside the lock file. Before the lock, a timing pilot ran the registration on training wells only. Two design choices used Volve data, and neither used a porosity value: the target window, taken from the positions of the labelled samples of the six wells, and the member-support rule (ii) below, taken from a CPU smoke test on training wells. The protocol records eleven deviations from F3, of which four matter for reading the result. (i) The label runs are 16--37 samples long, shorter than the 64-sample training windows and the 6\,Hz band split of F3, so the primary metric is total RMSE on the labelled samples, and the loss uses a single 126-sample window with a mask over the label support of each bank member. (ii) Each bank member trains on its own label support. The first draft intersected the supports of all members, which reduced F-11 A to 7 samples, below the minimum of 8; the intersection is kept as a diagnostic. (iii) Under the slot scheme the inner validation is leave-one-well-out rather than slot-blind, because three slots leave too few groups, so inner validation can be optimistic there. (iv) The anchor uncertainty $\sigma_a = 7$\,ms is inherited from F3, not estimated on Volve. One deviation occurred after the lock. The protocol listed the $\sigma_a$ arms after the primary arm on one GPU; they ran concurrently on a second GPU of the same type. The device is not part of the job fingerprint, every job seeds itself, and the primary-arm gate recomputed with all arms present was identical. Like F3, this is a post-failure design on a dataset we had inspected, not an independent replication.
|
||||
\paragraph{Data.}
|
||||
\label{sec:data:volve}
|
||||
Volve (Norwegian North Sea) was released by Equinor in 2018 \citep{equinor2018volve}; the licence files of the release name CC BY-NC-SA 4.0. Its role is to break the label structure of F3. The computed effective porosity PHIF of the operator's petrophysical interpretation is driven by density, not by sonic: within each well its correlation with RHOB is $-0.92$ to $-0.99$, RHOB and NPHI explain 84--98\% of its variance, and adding DT raises this by at most 0.9 percentage points. Six wells have DT, RHOB, neutron porosity (NPHI) and PHIF: F-1, F-1 A, F-1 B, F-11 A, F-11 T2 and F-12. All six are deviated (maximum inclination 30--82$^\circ$; 4--54$^\circ$ over the labelled interval), and they share one platform. F-1 A and F-1 B leave the F-1 borehole at 2587\,m measured depth (MD), and F-11 A leaves F-11 T2 at about 2580\,m MD, so the wells form three slot groups, \{F-1, F-1 A, F-1 B\}, \{F-11 A, F-11 T2\} and \{F-12\}, whose members share the hole above the kick-off.
|
||||
|
||||
We use the post-stack ST10010 full-angle stack (3--41$^\circ$), a 2011 depth migration converted to time, at 4\,ms sampling. Its trace headers carry an invalid time scalar that standard readers apply to the start time, which shifts every sample 8\,ms late. We use the start time of the text header (4\,ms) and checked it against five interpreted horizons: the amplitude extremum along each falls at a lag of 0 to $+2$\,ms. Trajectories come from the operator's definitive surveys; recomputing them by minimum curvature reproduces the listed true vertical depth (TVD) within 0.01\,m. The seismic input of a well is a $3\times3$ patch of traces interpolated bilinearly along the deviated path at the time given by its time--depth relation, because a vertical trace at one bin differs from the path composite by a relative RMS of 0.19--0.61 over the labelled interval. Learning uses the window 2400--2900\,ms (126 samples) and tie likelihoods the extended window 2000--3200\,ms.
|
||||
|
||||
Of the six wells, only F-11 T2 has a zero-offset vertical seismic profile (VSP). As anchors we use the operator's well picks with a TWT from the Ty Formation downwards, excluding picks flagged as not logged, not reached or faulted; each well has 4--9 such anchors within its logged sonic interval. Shallower picks are unreliable (picks at the same depth in a shared borehole differ by about 110\,ms). At reservoir level every unflagged pick lies within $\pm 10$\,ms of the corresponding interpreted horizon, and at F-11 T2 the picks lie within $-6.1$ to $+2.3$\,ms of the VSP. The pick times come from the operator's time--depth models, so they are interpretations, not measurements, as on F3. Time is vertical time: DT is integrated over TVD and calibrated to the anchors by stretching between them. At F-11 T2 this marker-calibrated sonic lies within $-2.4$ to $-0.8$\,ms of the VSP over the labelled interval. We keep $\sigma_a = 7$\,ms from F3; it is not estimated on Volve.
|
||||
|
||||
PHIF is used only where DT is valid, which leaves 16--37 labelled 4\,ms samples per well (150 in total) at 2509--2819\,ms. The labelled runs lie 25--179\,m below the deepest anchor, so their timing depends on the drift of the sonic below it. They are shorter than one period at 6\,Hz, so the band split of F3 cannot be the primary metric here; band PCC is computed only descriptively, on high-passed runs of at least 16 samples. The well means of PHIF range from 8.5\,p.u.\ at F-1 to 17.0\,p.u.\ at F-12, against standard deviations of 3.3--6.0\,p.u.\ within wells.
|
||||
|
||||
\paragraph{Design.}
|
||||
The six wells are held out under two schemes (Section~\ref{sec:data:volve}). Under \emph{lowo}, each well is the outer test well once and the other five train. Under \emph{slot}, the whole slot group of the test well is held out, so F-1 trains on F-11 A, F-11 T2 and F-12 only; for F-12, which is alone in its slot, the two schemes coincide and its rows are identical. Within the outer training wells, each is held out once as an inner validation well. The held-out well never supplies its picks, sonic or logs to its own input. Its path is placed in time by the mean TVDSS--TWT relation of the wells it is held out from, which also moves the 3$\times$3 patch laterally along the deviated trajectory (by up to 76\,m, F-1 A under slot). Registration ($\sigma_a = 7$\,ms, $P = 1024$, $S = 64$) uses the training wells of each model only. Budgets are chosen from $\{125, 250, 500, 1000, 2000\}$ by inner-validation MSE on the labelled samples, and the prediction at the outer well is the moment-matched mixture of the inner models at the selected budget and five seeds (25 members under lowo, 15--25 under slot). The reference is the marker-calibrated vertical sonic of the test well. Gate G-D is descriptive. ``Consistent improvement'' needs \mRML{} below the selected point tie (B3b, B3c or B3c-R, by inner validation) at no fewer than five of six wells under both schemes, the F3 rule of three of four scaled up. ``Calibrated'' needs macro coverage of the 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$ under both schemes. Neither wording can override the F3 result.
|
||||
The six wells are held out under two schemes. Under \emph{lowo}, each well is the outer test well once and the other five train. Under \emph{slot}, the whole slot group of the test well is held out, so F-1 trains on F-11 A, F-11 T2 and F-12 only; for F-12, which is alone in its slot, the two schemes coincide. Within the outer training wells, each is held out once as an inner validation well. The held-out well never supplies its picks, sonic or logs to its own input. Its path is placed in time by the mean TVDSS--TWT relation of the wells it is held out from, which also moves the 3$\times$3 patch laterally along the deviated trajectory (by up to 76\,m, F-1 A under slot). Registration ($\sigma_a = 7$\,ms, $N_p = 1024$, $S = 64$) uses the training wells of each model only. Budgets are chosen from $\{125, 250, 500, 1000, 2000\}$ by inner-validation MSE on the labelled samples, and the prediction at the outer well is the moment-matched mixture of the inner models at the selected budget and five seeds (25 members under lowo, 15--25 under slot). The reference is the marker-calibrated vertical sonic of the test well. The pass rule is descriptive. ``Consistent improvement'' needs the \mRML{} below the selected deterministic tie at no fewer than five of six wells under both schemes, the F3 rule of three of four scaled up. ``Calibrated'' needs macro coverage of the 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$ under both schemes.
|
||||
|
||||
\paragraph{Result: neither condition held.}
|
||||
Table~\ref{tab:volvegd} gives the per-well comparison. Under lowo, inner validation chose B3b at every well, and \mRML{} had lower RMSE at two wells (F-1 B by 1.1\% and F-11 T2 by 1.5\%). At the other four it was 0.4--4.6\% worse. Its macro RMSE was 6.50\,p.u.\ against 6.36\,p.u.\ for B3b. Under slot, inner validation chose B3c in the F-1 slot and B3b in the others, and \mRML{} improved at three wells. The two large ratios in that scheme, 0.85 at F-1 and 0.90 at F-1 B, are against B3c, which had the lowest inner-validation MSE in that fold but was worse than B3b at both test wells (8.04 against 7.27\,p.u.\ and 5.35 against 5.17\,p.u.); against B3b, \mRML{} is 5.7\% better at F-1 and 7.2\% better at F-1 B. Its macro RMSE under slot was 7.13\,p.u.\ against 7.32\,p.u.\ for the selected ties. Against \mPM, trained on the mean of the same posterior, \mRML{} was lower at three of six wells under lowo and four of six under slot, with macro differences of 0.02 and 0.13\,p.u. Macro coverage was 0.39 and 0.48 (lowo) and 0.35 and 0.47 (slot) for the 80\% and 90\% intervals, lower than on F3 and far below the bands. No well reached nominal coverage; the highest values were 0.68 and 0.72 at F-1 B. Nothing was changed after the test wells were scored. We make no claim of improvement and no claim of calibrated uncertainty on Volve.
|
||||
\paragraph{Neither condition held.}
|
||||
Under lowo, inner validation chose the calibrated sonic at every well, and the \mRML{} had lower RMSE at two wells (F-1 B by 1.1\% and F-11 T2 by 1.5\%) and was 0.4--4.6\% worse at the other four (Table~\ref{tab:volvegd}). Its macro RMSE was 6.50\,p.u.\ against 6.36\,p.u.\ for the calibrated sonic. Under slot, inner validation chose the correlation tie in the F-1 slot and the calibrated sonic in the others, and the \mRML{} improved at three wells. The two large ratios in that scheme, 0.85 at F-1 and 0.90 at F-1 B, are against the correlation tie, which had the lowest inner-validation MSE in that fold but was worse than the calibrated sonic at both test wells (8.04 against 7.27\,p.u.\ and 5.35 against 5.17\,p.u.); against the calibrated sonic, the \mRML{} is 5.7\% better at F-1 and 7.2\% better at F-1 B. Its macro RMSE under slot was 7.13\,p.u.\ against 7.32\,p.u.\ for the selected ties. Against the \mPM{}, the \mRML{} was lower at three of six wells under lowo and four of six under slot, with macro differences of 0.02 and 0.13\,p.u. Macro coverage was 0.39 and 0.48 (lowo) and 0.35 and 0.47 (slot) for the 80\% and 90\% intervals, and no well reached nominal coverage; the highest values were 0.68 and 0.72 at F-1 B.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{Gate G-D on Volve (label PHIF, marker-calibrated vertical-sonic reference, labelled samples in 2400--2900\,ms, $\sigma_a = 7$\,ms, combined ensembles). Competitor: the point tie chosen by inner validation. Ratio: RMSE of \mRML{} divided by that of the competitor. $n$: labelled 4\,ms samples. Coverage: fraction of those samples inside the central interval of \mRML. F-12 is alone in its slot, so its two rows are identical.}
|
||||
\caption{Volve pass rule (label PHIF, marker-calibrated vertical-sonic reference, labelled samples in 2400--2900\,ms, $\sigma_a = 7$\,ms, combined ensembles). Competitor: the deterministic tie chosen by inner validation. Ratio: RMSE of \mRML{} divided by that of the competitor. $n$: labelled 4\,ms samples. Coverage: fraction of those samples inside the central interval of \mRML. F-12 is alone in its slot, so its two rows are identical.}
|
||||
\label{tab:volvegd}
|
||||
\small
|
||||
\setlength{\tabcolsep}{4pt}
|
||||
@@ -201,20 +174,20 @@ Table~\ref{tab:volvegd} gives the per-well comparison. Under lowo, inner validat
|
||||
\toprule
|
||||
Scheme & Outer well & $n$ & competitor & ratio & improved & cov$_{80}$ & cov$_{90}$ \\
|
||||
\midrule
|
||||
lowo & F-1 & 37 & B3b & 1.035 & no & 0.459 & 0.541 \\
|
||||
& F-1 A & 20 & B3b & 1.004 & no & 0.450 & 0.550 \\
|
||||
& F-1 B & 25 & B3b & 0.989 & yes & 0.680 & 0.720 \\
|
||||
& F-11 A & 16 & B3b & 1.046 & no & 0.188 & 0.313 \\
|
||||
& F-11 T2 & 23 & B3b & 0.985 & yes & 0.261 & 0.435 \\
|
||||
& F-12 & 29 & B3b & 1.043 & no & 0.276 & 0.310 \\
|
||||
lowo & F-1 & 37 & Calibrated sonic & 1.035 & no & 0.459 & 0.541 \\
|
||||
& F-1 A & 20 & Calibrated sonic & 1.004 & no & 0.450 & 0.550 \\
|
||||
& F-1 B & 25 & Calibrated sonic & 0.989 & yes & 0.680 & 0.720 \\
|
||||
& F-11 A & 16 & Calibrated sonic & 1.046 & no & 0.188 & 0.313 \\
|
||||
& F-11 T2 & 23 & Calibrated sonic & 0.985 & yes & 0.261 & 0.435 \\
|
||||
& F-12 & 29 & Calibrated sonic & 1.043 & no & 0.276 & 0.310 \\
|
||||
& Macro & & & & 2/6 & 0.386 & 0.478 \\
|
||||
\midrule
|
||||
slot & F-1 & 37 & B3c & 0.852 & yes & 0.270 & 0.432 \\
|
||||
& F-1 A & 20 & B3c & 1.034 & no & 0.450 & 0.600 \\
|
||||
& F-1 B & 25 & B3c & 0.897 & yes & 0.600 & 0.720 \\
|
||||
& F-11 A & 16 & B3b & 1.002 & no & 0.188 & 0.375 \\
|
||||
& F-11 T2 & 23 & B3b & 0.988 & yes & 0.304 & 0.391 \\
|
||||
& F-12 & 29 & B3b & 1.043 & no & 0.276 & 0.310 \\
|
||||
slot & F-1 & 37 & Correlation tie & 0.852 & yes & 0.270 & 0.432 \\
|
||||
& F-1 A & 20 & Correlation tie & 1.034 & no & 0.450 & 0.600 \\
|
||||
& F-1 B & 25 & Correlation tie & 0.897 & yes & 0.600 & 0.720 \\
|
||||
& F-11 A & 16 & Calibrated sonic & 1.002 & no & 0.188 & 0.375 \\
|
||||
& F-11 T2 & 23 & Calibrated sonic & 0.988 & yes & 0.304 & 0.391 \\
|
||||
& F-12 & 29 & Calibrated sonic & 1.043 & no & 0.276 & 0.310 \\
|
||||
& Macro & & & & 3/6 & 0.348 & 0.472 \\
|
||||
\midrule
|
||||
\multicolumn{5}{l}{Required, under both schemes} & $\ge 5/6$ & $[0.75, 0.85]$ & $[0.85, 0.95]$ \\
|
||||
@@ -222,12 +195,16 @@ slot & F-1 & 37 & B3c & 0.852 & yes & 0.270 & 0.432 \\
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{No method had blind-well skill.}
|
||||
Table~\ref{tab:volveall} lists the five registered methods. Every macro $R^2$ was negative under both schemes ($-0.84$ to $-1.71$). Except at F-1 B ($R^2$ 0.10--0.34 for every method under lowo, 0.05--0.07 for \mPM{} and \mRML{} under slot), each method predicted the held-out well worse than that well's own label mean, which it cannot know. The macro PCC was 0.12--0.24. After the run we added one row for scale: a constant prediction at the pooled label mean of the outer training wells, with no seismic input. Its macro RMSE was 6.03\,p.u.\ (lowo) and 6.59\,p.u.\ (slot), below every network. Networks beat it only at F-1 and F-1 B (at F-1 under slot, only \mPM{} and \mRML); at the other four wells every network was worse than the constant under both schemes. The reason is the between-well variation of the label. The well means of PHIF span 8.5\,p.u.\ (F-1) to 17.0\,p.u.\ (F-12), while the within-well standard deviation is 3.3--6.0\,p.u. A held-out well therefore differs from the training mean by up to 6.4\,p.u.\ before any seismic information is used, and the networks reproduced this offset rather than correcting it: the mean error of \mRML{} at each well tracked the constant's (lowo: $+3.9$ against $+4.9$\,p.u.\ at F-1, $-5.4$ against $-4.3$ at F-11 A, $-6.8$ against $-6.0$ at F-12). After removing the per-well mean error, the standard deviation of the residual of \mRML{}, averaged over wells, was 5.2\,p.u.\ (lowo) and 5.1\,p.u.\ (slot), against an average within-well label standard deviation of 4.8\,p.u., and the standard deviation of its prediction along a well was 1.1--4.1\,p.u. The predictions varied less than the label and did not follow it. Allowing a free time shift of up to $\pm 64$\,ms between prediction and label (a diagnostic that never alters a score) raised the PCC of \mRML{} to 0.40--0.82. At three (lowo) and four (slot) of the six wells, however, the chosen shift was 56--64\,ms, at or near the search limit and far outside the tie posterior ($\sigpost$ below 10\,ms; see below). With 16--37 samples, the maximum over 33 lags is an optimistic statistic, and we read this diagnostic as uninformative. The differences between tie methods, up to 0.26\,p.u.\ in macro RMSE, are therefore differences between predictions that are all dominated by an error the tie does not control. The G-D comparison had no power on these wells, and its outcome is not evidence about RML in either direction.
|
||||
\paragraph{No method had blind-well skill, because the between-well level dominates.}
|
||||
Every macro $R^2$ was negative under both schemes ($-0.84$ to $-1.71$, Table~\ref{tab:volveall}). Except at F-1 B ($R^2$ 0.10--0.34 for every method under lowo, 0.05--0.07 for the \mPM{} and \mRML{} under slot), each method predicted the held-out well worse than that well's own label mean, which it cannot know. The macro PCC was 0.12--0.24. A constant prediction at the pooled label mean of the outer training wells, added after the run for scale, had a macro RMSE of 6.03\,p.u.\ (lowo) and 6.59\,p.u.\ (slot), below every network. Networks beat it only at F-1 and F-1 B (at F-1 under slot, only the \mPM{} and \mRML{}).
|
||||
|
||||
The reason is the between-well variation of the label. The well means of PHIF span 8.5\,p.u.\ (F-1) to 17.0\,p.u.\ (F-12), so a held-out well differs from the training mean by up to 6.4\,p.u.\ before any seismic information is used. The networks reproduced this offset rather than correcting it: the mean error of the \mRML{} at each well tracked the constant's (lowo: $+3.9$ against $+4.9$\,p.u.\ at F-1, $-5.4$ against $-4.3$ at F-11 A, $-6.8$ against $-6.0$ at F-12). After removing the per-well mean error, the standard deviation of its residual, averaged over wells, was 5.2\,p.u.\ (lowo) and 5.1\,p.u.\ (slot), against an average within-well label standard deviation of 4.8\,p.u., and the standard deviation of its prediction along a well was 1.1--4.1\,p.u. The predictions varied less than the label and did not follow it.
|
||||
|
||||
A free time shift of up to $\pm 64$\,ms between prediction and label, a diagnostic that never alters a score, raised the PCC of the \mRML{} to 0.40--0.82. At three (lowo) and four (slot) of the six wells, however, the chosen shift was 56--64\,ms, at or near the search limit and far outside the tie posterior ($\sigpost$ below 10\,ms). With 16--37 samples, the maximum over 33 lags is an optimistic statistic, and we read this diagnostic as uninformative. The differences between tie methods, up to 0.26\,p.u.\ in macro RMSE, are differences between predictions that are all dominated by an error the tie does not control. The comparison had no power on these wells, and its outcome is not evidence about RML in either direction.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{Volve nested blind folds, all registered methods (label PHIF, marker-calibrated vertical-sonic reference, $\sigma_a = 7$\,ms, combined ensembles). Macro over six wells; RMSE in p.u. Coverage is descriptive. Last row: a constant prediction at the pooled label mean of the outer training wells, with no seismic input; computed after the run, for scale only.}
|
||||
\caption{Volve nested blind folds, all pre-registered methods (label PHIF, marker-calibrated vertical-sonic reference, $\sigma_a = 7$\,ms, combined ensembles). Macro over six wells; RMSE in p.u. Coverage is descriptive. Last row: a constant prediction at the pooled label mean of the outer training wells, with no seismic input; computed after the run, for scale only.}
|
||||
\label{tab:volveall}
|
||||
\small
|
||||
\begin{tabular}{lcccccccc}
|
||||
@@ -236,9 +213,9 @@ Table~\ref{tab:volveall} lists the five registered methods. Every macro $R^2$ wa
|
||||
\cmidrule(lr){2-5}\cmidrule(lr){6-9}
|
||||
Method & RMSE & $R^2$ & cov$_{80}$ & cov$_{90}$ & RMSE & $R^2$ & cov$_{80}$ & cov$_{90}$ \\
|
||||
\midrule
|
||||
B3b & 6.36 & $-0.84$ & 0.38 & 0.46 & 7.29 & $-1.64$ & 0.32 & 0.43 \\
|
||||
B3c & 6.55 & $-0.97$ & 0.32 & 0.40 & 7.32 & $-1.71$ & 0.33 & 0.40 \\
|
||||
B3c-R & 6.61 & $-1.02$ & 0.32 & 0.39 & 7.24 & $-1.61$ & 0.29 & 0.35 \\
|
||||
Calibrated sonic & 6.36 & $-0.84$ & 0.38 & 0.46 & 7.29 & $-1.64$ & 0.32 & 0.43 \\
|
||||
Correlation tie & 6.55 & $-0.97$ & 0.32 & 0.40 & 7.32 & $-1.71$ & 0.33 & 0.40 \\
|
||||
Phase-est.\ corr. & 6.61 & $-1.02$ & 0.32 & 0.39 & 7.24 & $-1.61$ & 0.29 & 0.35 \\
|
||||
\mPM & 6.52 & $-0.96$ & 0.39 & 0.45 & 7.26 & $-1.59$ & 0.33 & 0.44 \\
|
||||
\mRML & 6.50 & $-0.92$ & 0.39 & 0.48 & 7.13 & $-1.48$ & 0.35 & 0.47 \\
|
||||
\midrule
|
||||
@@ -247,19 +224,20 @@ Constant (training mean) & \textbf{6.03} & $-0.70$ & -- & -- & \textbf{6.59} & $
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{Anchor uncertainty.}
|
||||
B3c-R, \mPM{} and \mRML{} were registered and trained again at $\sigma_a = 3.5$ and 14\,ms (Table~\ref{tab:volvesens}). The macro RMSE of \mRML{} moved by at most 0.07\,p.u.\ (lowo: 6.49, 6.50 and 6.55\,p.u.; slot: 7.13, 7.13 and 7.09\,p.u.), and coverage stayed between 0.35 and 0.52. The number of wells at which \mRML{} beat B3c-R varied between two and four of six, with no pattern across the arms. In Experiment~2 the H2a advantage depended on $\sigma_a$, and on F3 the arms changed the per-well ratios but not the outcome. On Volve they barely changed the macro error, which is consistent with the previous paragraph: when the error is set by the between-well level, the tie has little to act on.
|
||||
\paragraph{The anchor uncertainty barely changed the error.}
|
||||
The phase-estimated correlation, the \mPM{} and the \mRML{} were registered and trained again at $\sigma_a = 3.5$ and 14\,ms (Table~\ref{tab:volvesens}). The macro RMSE of the \mRML{} moved by at most 0.07\,p.u.\ (lowo: 6.49, 6.50 and 6.55\,p.u.; slot: 7.13, 7.13 and 7.09\,p.u.), and coverage stayed between 0.35 and 0.52. The number of wells at which the \mRML{} beat its competitor varied between two and four of six, with no pattern across the arms. This is consistent with the previous paragraph: when the error is set by the between-well level, the tie has little to act on.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{Volve sensitivity to $\sigma_a$ (combined ensembles, descriptive). Macro RMSE in p.u.\ of \mRML{} and of B3c-R at the same $\sigma_a$; improved: wells at which \mRML{} is below B3c-R; coverage of \mRML. The registered comparison of Table~\ref{tab:volvegd} is against the tie chosen by inner validation, which is B3b at most wells, so its counts differ.}
|
||||
\caption{Volve sensitivity to $\sigma_a$ (combined ensembles, descriptive). Macro RMSE in p.u.\ of \mRML{} and of Phase-est.\ corr. at the same $\sigma_a$; improved: wells at which \mRML{} is below Phase-est.\ corr.; coverage of \mRML. The pre-registered comparison of Table~\ref{tab:volvegd} is against the tie chosen by inner validation, which is Calibrated sonic at most wells, so its counts differ.}
|
||||
\label{tab:volvesens}
|
||||
\small
|
||||
\setlength{\tabcolsep}{2.5pt}
|
||||
\begin{tabular}{lcccccccc}
|
||||
\toprule
|
||||
& \multicolumn{4}{c}{lowo} & \multicolumn{4}{c}{slot} \\
|
||||
\cmidrule(lr){2-5}\cmidrule(lr){6-9}
|
||||
$\sigma_a$ (ms) & \mRML & B3c-R & improved & cov$_{90}$ & \mRML & B3c-R & improved & cov$_{90}$ \\
|
||||
$\sigma_a$ (ms) & \mRML & Phase-est.\ corr. & improved & cov$_{90}$ & \mRML & Phase-est.\ corr. & improved & cov$_{90}$ \\
|
||||
\midrule
|
||||
3.5 & 6.49 & 6.65 & 4/6 & 0.48 & 7.13 & 7.28 & 3/6 & 0.42 \\
|
||||
7 & 6.50 & 6.61 & 4/6 & 0.48 & 7.13 & 7.24 & 2/6 & 0.47 \\
|
||||
@@ -268,5 +246,10 @@ $\sigma_a$ (ms) & \mRML & B3c-R & improved & cov$_{90}$ & \mRML & B3c-R & improv
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{Posterior width and phase.}
|
||||
Over the 78 training-well registrations of the primary arm, $\sigpost$ of the SMC posterior was 1.9--9.3\,ms over the main window (median 4.3\,ms) and 3.0\,ms over the labelled samples. It was narrowest at F-11 T2 (1.9--2.6\,ms) and widest at F-12 (4.3--9.3\,ms). Unlike F3, the width barely followed $\sigma_a$: the medians were 3.8, 4.3 and 4.1\,ms at 3.5, 7 and 14\,ms. This is consistent with the seismic likelihood rather than the anchor prior setting the width over the logged interval, but we did not test it. By the rule of Experiment~2 every training set was wide. The wavelet phase was better identified than on F3: the 22 phases of the primary arm lay within an arc of 43$^\circ$, against 214$^\circ$ on F3. A well-identified phase and a width set by the data rather than by $\sigma_a$ suggest that registration was not the limiting step, although on field data this cannot be checked against a true warp. The limiting step was the predictive task itself: with 150 labelled samples in six wells, between-well level differences of up to 8.5\,p.u.\ and a target window 2.4--2.9\,s deep in a deviated-well field, the seismic input did not carry the information needed to predict PHIF at a blind well by any of the methods tested.
|
||||
\paragraph{The posterior width was set by the data, and registration was not the limiting step.}
|
||||
Over the 78 training-well registrations of the primary arm, $\sigpost$ was 1.9--9.3\,ms over the main window (median 4.3\,ms) and 3.0\,ms over the labelled samples, narrowest at F-11 T2 (1.9--2.6\,ms) and widest at F-12 (4.3--9.3\,ms). Unlike F3, the width barely followed $\sigma_a$: the medians were 3.8, 4.3 and 4.1\,ms at 3.5, 7 and 14\,ms. This is consistent with the seismic likelihood rather than the anchor prior setting the width over the logged interval, but we did not test it. The wavelet phase was better identified than on F3: the 22 phases of the primary arm lay within an arc of 43$^\circ$, against 214$^\circ$ on F3. These features suggest that registration was not the limiting step, although on field data this cannot be checked against a true warp. The limiting step was the predictive task itself: with 150 labelled samples in six wells, between-well level differences of up to 8.5\,p.u.\ and a target window 2.4--2.9\,s deep in a deviated-well field, the seismic input did not carry the information needed to predict PHIF at a blind well by any of the methods tested.
|
||||
|
||||
\subsection{Teapot Dome inventory}
|
||||
\label{sec:exp:teapot}
|
||||
|
||||
This step is post hoc and exploratory. Time--depth tables exist at four of the 152 wells: two are labelled as derived from a synthetic log, one from a synthetic seismogram, and the fourth, a vertical seismic profile, ends above the main reservoirs. As an alternative reference, we paired the times of two interpreted 3-D horizons at the wells with the depths of the corresponding formation tops. On 37 development wells we predicted each time from the depth with a quadratic lateral trend of average velocity, fitted by leave-one-out. The residual standard deviation was 6.75\,ms (90\% bootstrap interval over wells 4.1--9.4\,ms; robust estimate 5.0\,ms). Most of it was a bulk shift per well (6.6\,ms): the residuals of the two horizons at a well were correlated (0.85), and those of neighbouring wells were not, which resembles per-well errors of datum, statics or top picks. The differential part was 2.8\,ms, and 2.5\,ms from the sonic at five wells. Every estimate exceeded the declared tolerance of 1.5\,ms, the largest grid value at which the $-5$\,dB cell with $N = 16$ reaches a power of 0.8 with no more than the 115 remaining wells (58 wells by the formula of the power analysis).
|
||||
|
||||
Reference in New Issue
Block a user