Audit the manuscript for unsupported claims and rewrite flagged text
Five independent audits traced every number, citation and claim in the manuscript to outputs/, the locked protocols, the code and the reference texts (87 findings, 4 of severity S1). Fixes were verified and applied as 106 exact replacements; a protected-token guard confirms that only the approved numbers and citations changed. A style pass split seven overlong sentences. No verdict, gate or threshold changed. - S1: the two time-depth models were conflated as "up to 36 ms"; the warp prior is fitted by MAP-II with sigma_a = 7 ms and sigma_b = 50 ms fixed (19 ms comes from a separate ML fit); the Exp. 1 protocol was hash-locked, not tagged; PHIE_DT is linear in sonic at all four F3 wells. - tab:audit now follows outputs/td_qc.csv; unsupported intro citations (prabowo2025f3, tao2025structural, DILATE) dropped; claims scoped to the regimes actually tested; about 40 small number fixes. - Restore docs/technical_overview.md (the lecture moves to docs/lecture.md). - Audit record in docs/research/paper-audit.md; plan, AGENTS.md, report.html, paper/README.md and self_review.md synced (69 pages). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -20,7 +20,7 @@ with the `.venv`), except `bench_s1.pdf` and `bench_s8.pdf` (Experiment 3), whic
|
||||
| Abstract, Sec. 1 (findings paragraph), Sec. 8, `highlights.txt` | Rows below: H2a and σ_a from `tab:h2a`/`tab:sigmaa`; bank gain and bounds (registered (a), post hoc (b)) from `tab:h2b` and `outputs/p2r/posthoc/{bound.csv,meta.json}`; wells needed from `outputs/t3/nstar.csv`; field results from App. B; Teapot counts from Sec. 6.7 sources; Experiment 3 (9/11 verdicts, failures, two-mode reversal) from the Sec. 6.5 rows |
|
||||
| Sec. 1 (F3 drift 14–66 ms, 46 ms, 36 ms; dominant period 17–20 ms) | `outputs/td_qc.csv`, `outputs/tie_qc.csv`, `docs/plan.md` §1.2 |
|
||||
| Sec. 2 (label noise and errors in variables; Table `tab:positioning`) | `refs.bib` `annote` fields: Mnih & Hinton (2012) read in full on 2026-10-29 (Secs. 5, 6.1, 6.3); Balakrishnan (1962) metadata from Crossref only, cited for the general statement; abstract-only entries flagged in the table. Preliminary novelty scan of 2026-11-02 (`docs/plan.md` §12 item 31): Herrera & van der Baan (2014), da Costa Silva et al. (2026, Autotie) and Castagna et al. (2026) from their abstracts (OpenAlex), metadata from Crossref (Castagna et al. later read in full, 2026-11-02: timing-error remarks in their Discussion, `docs/plan.md` §12 item 33); the label source of Sukar et al. (2026) from the full text in `refs/` (Sec. 3, "Data preparation"). Full texts obtained on 2026-11-02 (`docs/plan.md` §12 item 33): Lim et al. (2025, AWSM; 44 wells, median/minimum-misfit models, TD posterior not used downstream), Lim & Cardona (2025, BootNet), Li, Grana & Liu (2024, P05; deterministic tie in the field case), Guillon et al. (2020; tolerance in evaluation only) and Rizzuti et al. (2024, 2025; wavelet treated as known, future-work statement); their ᵃ markers were removed |
|
||||
| Sec. 3, Table `tab:audit` (TD drift, label audit) | `outputs/td_qc.csv`, `outputs/tie_qc.csv`, `outputs/marker_vs_horizon.csv`, `docs/plan.md` |
|
||||
| Sec. 3, Table `tab:audit` (TD drift, label audit; max \|Δt_wlt\| column from `td_qc.csv` since the 04/11 audit) | `outputs/td_qc.csv`, `outputs/tie_qc.csv`, `outputs/marker_vs_horizon.csv`, `docs/plan.md` |
|
||||
| Sec. 3.2, paragraph "Misspecification (Experiment 3)" (presets, scale factors, Q 80 peak shift, model error 0.23 nominal and 1.08–1.93 for the presets, L1 levels above the declared band, minphase 0.25 candidate, Rm5 null 1.78× and 0.22–0.34) | Presets: `configs/protocol_bench.yaml` (`studies.S2.presets`) and the `misspec_presets` block of `configs/d2_synth_bench.yaml`; generator `ml_porosity/data/synth_d2.py` (`misspec=`); level choice on dev 902–905 and the model-error table: `docs/research/bench-protocol.md` (S2 level table and decisions) and `docs/research/bench-generator.md`, QC from `scripts/33_bench_generator_qc.py` |
|
||||
| Sec. 3.3 (Volve data: licence, label check, deviated wells, cube, time–depth, anchors, labels) | `outputs/volve/volve_wells_summary.json`, `outputs/volve/{summary.json,anchors.csv,pick_vs_horizon.csv,pick_vs_checkshot.csv,horizon_lag.csv}`, `docs/research/volve-inventory.md`, `docs/plan.md` §12 items 7 and 18 |
|
||||
| Sec. 4, Table `tab:h1`, Fig. `fig:h1` | `outputs/p2/summary/main/h1.csv`, `docs/theory.md` |
|
||||
@@ -72,4 +72,4 @@ Wording must respect `docs/plan.md` §10 (forbidden claims).
|
||||
|
||||
Length: Computers & Geosciences limits a Research Article to about 5,500 words excluding abstract, keywords, highlights,
|
||||
references and captions (secondary source; the official Guide for Authors page could not be fetched on 2026-10-29).
|
||||
The main text (Secs. 1–8) is about 18,100 words (crude count after the 02/11 writing pass, which added about 3,100 words for Experiment 3, the mechanism study and the discussion; the proof review of the same day added about 350 more and the full-text pass of Sec. 2 about 130, estimated; 68 pages), and exceeds that limit. The length pass was dropped by the user on 2026-10-29 (`docs/plan.md` §12 item 25).
|
||||
The main text (Secs. 1–8) is about 18,100 words (crude count after the 02/11 writing pass, which added about 3,100 words for Experiment 3, the mechanism study and the discussion; the proof review of the same day added about 350 more and the full-text pass of Sec. 2 about 130, estimated; the hallucination audit of 04/11 added about 600 more, crude count; 69 pages), and exceeds that limit. The length pass was dropped by the user on 2026-10-29 (`docs/plan.md` §12 item 25).
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
Well-tie error in training labels is an error in the time index of the label
|
||||
Misregistered labels blur the learned predictor; Berkson-type tie error sharpens it
|
||||
A calibrated posterior bank recovers the oracle optimum; its gain is fourth order
|
||||
Tie-posterior label gains on the benchmark fail if anchor error is misset twofold
|
||||
Blind-well tests need references accurate to ~1 ms; tested public datasets lack them
|
||||
In one tested regime, tie-posterior label gains fail if anchor error is off twofold
|
||||
In simulation, blind-well tests need ~1 ms references; tested field data lack them
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
\begin{abstract}
|
||||
Seismic reservoir-property predictors are trained on well logs that a well tie places in two-way time, and the tie is uncertain. We analyse its error as an error in the time index of the label. Under an independence assumption, misregistered labels convolve the optimal predictor with the error distribution and blur the seismic band; a controlled experiment matched the predicted transfer to within 1\% for errors of 4--16\,ms. Without time anchors, absolute timing is not identified. In a linear-Gaussian idealization, a tie computed as a posterior mean has the opposite, Berkson, error structure and sharpens the predictor instead. A calibrated bank of posterior labels attains the oracle's population optimum, but its population gain over a point label is of fourth order in the tie error. On a registration-aware synthetic benchmark calibrated to F3, we compared point ties, posterior-mean labels and a tempered likelihood over a posterior bank under pre-registered rules. The first comparison failed, and the second was designed after that failure. There, posterior-mean labels had 8--22\% lower seismic-band RMSE than the best point tie, most of it already without drift, but failed when the anchor uncertainty was set at half or twice its true value. With 16 training wells, the bank gained further in all eight cells with a wide posterior. This gain exceeded the registered population bound for classical tie error in seven cells, but in only three the post hoc bound for Berkson error, the structure that an exploratory test found at F3-like drift. A third pre-registered experiment, designed after the field tests and run on the same test realizations, passed 9 of its 11 verdicts. The posterior-mean advantage extended to stronger drift, a second backbone and a misspecified warp prior, but not to a frequency-dependent wavelet phase, which made the tie posterior overconfident, nor, by the registered margin, to unit-dependent rock physics. With a two-mode label error, midpoint labels reversed the sign of the learned seismic band as predicted, and a two-member bank containing the true warp removed the reversal. Detecting such gains at blind wells requires an accurate reference: with an exact reference, 5--18 wells gave a power of 0.8 in most cells; with reference errors of 3\,ms or more, 40 wells did not. The F3 and Volve field tests (four and six wells) failed, and neither could have detected such gains. Teapot Dome has independent time--depth references at no more than two of its 152 wells. We make no field or calibration claim.
|
||||
Seismic reservoir-property predictors are trained on well logs that a well tie places in two-way time, and the tie is uncertain. We analyse its error as an error in the time index of the label. Under an independence assumption, misregistered labels convolve the optimal predictor with the error distribution and blur the seismic band; a controlled experiment matched the predicted transfer to within 1\% for errors of 4--16\,ms. Without time anchors, absolute timing is not identified. In a linear-Gaussian idealization, a tie computed as a posterior mean has the opposite, Berkson, error structure and sharpens the predictor instead. A calibrated bank of posterior labels attains the oracle's population optimum, but its population gain over a point label is of fourth order in the tie error. On a registration-aware synthetic benchmark calibrated to F3, we compared point ties, posterior-mean labels and a tempered likelihood over a posterior bank under pre-registered rules. The first comparison failed, and the second was designed after that failure. There, posterior-mean labels had 8--22\% lower seismic-band RMSE than the best point tie, most of it already without drift, but, in the one regime tested (R10, $c = 1$), no longer passed the registered rule when the anchor uncertainty was set at half or twice its true value. With 16 training wells, the bank gained further in all eight cells with a wide posterior. This gain exceeded the registered population bound for classical tie error in seven cells, but in only three (one with its interval clear of the bound) the post hoc bound for Berkson error, the structure that an exploratory test found at F3-like drift. A third pre-registered experiment, designed after the field tests and run on the same test realizations, passed 9 of its 11 verdicts. At R10, the posterior-mean advantage extended to stronger drift ($c = 1.5$), a second backbone and the milder of two misspecified warp priors, but not to a frequency-dependent wavelet phase, which made the tie posterior overconfident, nor, by the registered margin, to unit-dependent rock physics. With a two-mode label error, midpoint labels reversed the sign of the learned seismic band as predicted, and a two-member bank containing the true warp removed the reversal. In an exploratory power analysis under the benchmark simulator, detecting such gains at blind wells required an accurate reference: with an exact reference, 5--18 wells gave a power of 0.8 in most cells; with reference errors of 3\,ms or more, 40 wells did not. The F3 and Volve field tests (four and six wells) failed, and neither could have detected such gains. Teapot Dome has independent time--depth references at no more than two of the 152 wells with density logs across its target inside the 3-D survey. We make no field or calibration claim.
|
||||
\end{abstract}
|
||||
|
||||
\noindent\textbf{Keywords:} well tie; registration error; errors-in-variables; seismic porosity prediction; synthetic benchmark; blind-well validation; statistical power
|
||||
|
||||
@@ -1,20 +1,20 @@
|
||||
\section{Introduction}
|
||||
\label{sec:intro}
|
||||
|
||||
Deep networks are widely used to map seismic amplitudes to reservoir properties such as porosity. The common workflow has four steps: tie each well to the seismic, resample the depth logs to two-way time (TWT), train a regressor from seismic to the time-domain labels, and score blind wells against labels produced by the same tie \citep[e.g.][]{xu2024sts,prabowo2025f3,tao2025structural,liu2023lowfrequency}. In this workflow the well tie is a preprocessing step. Its output, a single time--depth curve per well, is treated as exact.
|
||||
Deep networks are widely used to map seismic amplitudes to reservoir properties such as porosity. The common workflow has four steps: tie each well to the seismic, resample the depth logs to two-way time (TWT), train a regressor from seismic to the time-domain labels, and score blind wells against labels produced by the same tie \citep[e.g.][]{xu2024sts,liu2023lowfrequency}. In this workflow the well tie is a preprocessing step. Its output, a single time--depth curve per well, is treated as exact.
|
||||
|
||||
The tie is not exact. It is an inverse problem with a posterior distribution, and Bayesian treatments of it have existed for two decades and are still being developed \citep{buland2003bayesianwavelet,gunning2006waveletextractor,lim2025awsm}. In those treatments the posterior is the end product: no learning step uses it.
|
||||
|
||||
The size of the timing error is easy to underestimate. At the four public wells of the F3 block, sonic-integrated TWT differs from the interpreted time--depth markers by up to 14--66\,ms, and the difference changes by up to 46\,ms inside a 500\,ms target window (Section~\ref{sec:data}). Two time--depth models distributed with the data disagree with the markers by up to 36\,ms. The dominant period of the seismic is 17--20\,ms. Label timing errors of one to several periods are therefore realistic, and they vary with depth, so a bulk lag cannot absorb them.
|
||||
The size of the timing error is easy to underestimate. At the four public wells of the F3 block, sonic-integrated TWT differs from the interpreted time--depth markers by up to 14--66\,ms, and the difference changes by up to 46\,ms inside a 500\,ms target window (Section~\ref{sec:data}). The OpendTect time--depth model distributed with the data deviates from the markers by up to 36\,ms, and a second set of model files is offset from them by $-15$ to $+41$\,ms on average. The dominant period of the seismic is 17--20\,ms. Label timing errors of one to several periods are therefore realistic, and they vary with depth, so a bulk lag cannot absorb them.
|
||||
|
||||
This is a label error of a particular kind. The label values are measured, but they are placed at the wrong times. Work on noisy labels and on errors in variables mostly concerns errors in the values (Section~\ref{sec:related}). A registration error acts on the time index instead: it is correlated along the well, its effect depends on frequency, and it affects the reference against which blind wells are scored as well as the training labels. We ask what such an error does to a learned predictor, whether training on a tie posterior rather than a point tie removes its effect, and whether a field test can detect the difference. We make four contributions.
|
||||
\begin{enumerate}
|
||||
\item[C1] \textbf{Theory.} Under an independence assumption, the MSE-optimal predictor trained on misregistered labels is the correctly registered predictor convolved with the distribution of the timing error, so the seismic band is attenuated by the characteristic function of the error (Proposition~\ref{prop:blur}). A controlled experiment matches this transfer to within 1\% for errors of 4--16\,ms, in the band where the predictor has coherent power. Without time anchors, a shared network and its label alignment can drift together without changing the loss (Proposition~\ref{prop:ident}), so losses that learn the alignment from the network's own predictions, such as soft-DTW \citep{cuturi2017softdtw} and DILATE \citep{leguen2019dilate}, cannot fix absolute timing. The error of an estimated tie can have the classical structure, which blurs the learned predictor, or the Berkson structure, which sharpens it (Proposition~\ref{prop:tie}). A calibrated bank of posterior labels has the population minimizer of training on the true labels, but its population gain over a point label is of fourth order in the tie error (Proposition~\ref{prop:bank}). We also relate the coverage of predictive intervals to the error structure (Proposition~\ref{prop:coverage}) and give the bias of scoring against a misregistered reference (Proposition~\ref{prop:reference}).
|
||||
\item[C1] \textbf{Theory.} Under an independence assumption, the MSE-optimal predictor trained on misregistered labels is the correctly registered predictor convolved with the distribution of the timing error, so the seismic band is attenuated by the characteristic function of the error (Proposition~\ref{prop:blur}). A controlled experiment matches this transfer to within 1\% for errors of 4--16\,ms, in the band where the predictor has coherent power. Without time anchors, a shared network and its label alignment can drift together without changing the loss (Proposition~\ref{prop:ident}), so losses that learn the alignment from the network's own predictions, such as soft-DTW \citep{cuturi2017softdtw}, cannot fix absolute timing. The error of an estimated tie can have the classical structure, which blurs the learned predictor, or the Berkson structure, which sharpens it (Proposition~\ref{prop:tie}). A calibrated bank of posterior labels has the population minimizer of training on the true labels, but its population gain over a point label is of fourth order in the tie error (Proposition~\ref{prop:bank}). We also relate the coverage of predictive intervals to the error structure (Proposition~\ref{prop:coverage}) and give the bias of scoring against a misregistered reference (Proposition~\ref{prop:reference}).
|
||||
\item[C2] \textbf{A registration-aware benchmark.} We build synthetic data with known true warps from F3 geometry, rock physics and time--depth statistics. We vary drift, seismic signal-to-noise ratio and anchor density, and evaluate under locked, pre-registered pass rules. We report both comparisons that we registered: the first failed, and the second, designed after that failure, passed, with an explicit dependence on correctly specified anchor uncertainty. A third experiment, designed after the field tests, fills the plane of drift and well count, misspecifies the rock physics, the wavelet and the drift, adds the anchor-free losses and a second backbone, and imposes a two-mode label error of known structure. We release it as a task package with hidden truth and a scorer that applies the locked rules.
|
||||
\item[C3] \textbf{A family of baselines.} Registration-marginalized learning (RML$_\lambda$), a tempered log-likelihood over a bank of labels, contains point-tie training, hard-min and soft-min shift losses and soft-DTW as special cases (Lemmas~\ref{lem:s1}--\ref{lem:sdtw}). We use this family to define the methods compared on the benchmark, not as a proposed method that wins.
|
||||
\item[C4] \textbf{Detectability and the scope of field tests.} We derive how accurately the reference at blind wells must be tied, and how many blind wells are needed, for a comparison of tie methods to detect the effects of C1 (Corollary~\ref{cor:tolerance}, Section~\ref{sec:exp:detect}). We audit the public F3 well data: the porosity labels at three of the four wells are a linear function of the sonic log, and the time--depth markers are horizon-tie picks, not check shots. Pre-registered field tests on F3 and Volve failed, and an inventory of Teapot Dome found an independent time--depth reference at no more than two of its wells. These cases bound the scope of the paper.
|
||||
\end{enumerate}
|
||||
|
||||
On the benchmark, labels at the posterior-mean warp of a sequential Monte Carlo tie beat the best point tie by 8--22\% in seismic-band RMSE at F3-like drift in all three full-anchor regimes. Most of this advantage was already present without drift, so part of it comes from the seismic-conditioned tie itself rather than from correcting drift. With the anchor uncertainty set at half or twice its true value, this advantage no longer passed the registered rule. A bank of posterior samples gained further when the posterior was wide, in all eight such cells with 16 training wells. In seven of these eight cells this gain exceeded the population bound that we registered, which assumes classical tie error, but in only three did it exceed the bound for the Berkson error of a posterior-mean tie, which we computed post hoc; an exploratory test found the Berkson structure at F3-like drift. In the third experiment, 9 of 11 pre-registered verdicts passed. The posterior-mean advantage held at stronger drift, with a second backbone and under a misspecified warp prior, but failed under a frequency-dependent wavelet phase and, by the registered margin, under unit-dependent rock physics. The bank gain grew with the number of wells, and a two-mode label error reversed the sign of the learned seismic band as predicted, a reversal that a bank containing the true warp removed. With an exact reference, a sign test at blind wells needed 5--18 wells to detect these gains in most cells, and with reference errors of 3\,ms or more, 40 wells did not suffice. Neither public field dataset that we tested meets these conditions.
|
||||
On the benchmark, labels at the posterior-mean warp of a sequential Monte Carlo tie beat the best point tie by 8--22\% in seismic-band RMSE at F3-like drift in all three full-anchor regimes. Most of this advantage was already present without drift, so part of it comes from the seismic-conditioned tie itself rather than from correcting drift. In the one regime where we tested it (R10, $c = 1$), setting the anchor uncertainty at half or twice its true value made this advantage fail the registered rule. A bank of posterior samples gained further when the posterior was wide, in all eight such cells with 16 training wells. In seven of these eight cells this gain exceeded the population bound that we registered, which assumes classical tie error, but in only three (one with its interval clear of the bound) did it exceed the bound for the Berkson error of a posterior-mean tie, which we computed post hoc; an exploratory test found the Berkson structure at F3-like drift. In the third experiment, 9 of 11 pre-registered verdicts passed. At R10, the posterior-mean advantage held at stronger drift ($c = 1.5$), with a second backbone and under the milder of two misspecified warp priors, but failed under a frequency-dependent wavelet phase and, by the registered margin, under unit-dependent rock physics. The bank gain grew with the number of wells, and a two-mode label error reversed the sign of the learned seismic band as predicted, a reversal that a bank containing the true warp removed. In an exploratory power analysis under the benchmark simulator, with an exact reference, a sign test at blind wells needed 5--18 wells to detect these gains in most cells, and with reference errors of 3\,ms or more, 40 wells did not suffice. Neither public field dataset that we tested meets these conditions.
|
||||
|
||||
Section~\ref{sec:related} positions the work. Section~\ref{sec:data} describes the data and the audit, Section~\ref{sec:theory} the theory, and Section~\ref{sec:method} the tie posterior and the methods. Section~\ref{sec:experiments} reports the benchmark, the detectability analysis and the field cases. Section~\ref{sec:discussion} discusses what the results imply for field studies, and the limitations. Proofs are in Appendix~\ref{app:proofs}, and the field tests in Appendix~\ref{app:field}.
|
||||
|
||||
@@ -4,13 +4,13 @@
|
||||
Three bodies of work meet in this problem and have so far been developed separately: well ties with uncertainty, learned property prediction from few wells, and losses that tolerate temporal misalignment. Two others study uncertain labels, in statistics and machine learning in general and in learned seismic interpretation. We review each in turn and then state what is new.
|
||||
|
||||
\paragraph{Well ties and their uncertainty.}
|
||||
Posteriors over the well tie exist, but in every method we found the tie is the end product. \citet{buland2003bayesianwavelet} model the mistie between seismic time and log time as latent marker shifts with a triangular prior. They estimate these shifts jointly with the wavelet by MCMC and report their posterior. \citet{gunning2006waveletextractor} estimate the wavelet jointly with check-shot and marker times (Gaussian priors, monotonicity enforced), a registration shift and a lateral positioning error per well. They obtain uncertainty from a Laplace approximation and choose the wavelet length by marginal likelihood. \citet{lim2025awsm} start from a time--depth model anchored to an interpreted horizon and a well top, sample its stretch, shift and pinch-point parameters jointly with the wavelet by parallel-tempering MCMC, and report the resulting time--depth uncertainty for 44 wells in the Midland Basin. Neither prior over time shifts nor a posterior over the time--depth relation is therefore new. In these works, however, the posterior is not used further. \citet{lim2025awsm} keep two representative samples, the median-misfit and the minimum-misfit model, and estimate angle-consistent wavelets for AVO/AVA inversion; no later step in their workflow uses the time--depth posterior. \citet{wu2017multiwelltie} tie several wells at once with smooth depth-variable shifts and give no tie uncertainty. \citet{herrera2012automatedtie} use dynamic time warping for the tie. In the published version \citep{herrera2014semiautomatic}, the warping replaces the manual stretch-and-squeeze step within bounds set by the interpreter, and is meant as a guide rather than a blind method. \citet{dacostasilva2026autotie} combine time-weighted dynamic time warping, Bayesian optimization of the tie parameters and segment-wise alignment; their abstract reports higher correlations at six wells and no tie uncertainty. Among learning-based methods, \citet{tschannen2022partialtie} estimate the wavelet with a variational network: their uncertainty is mainly in wavelet phase, and the bulk shift is found by Bayesian optimization within user-set bounds. \citet{di2023welltie} and \citet{li2025cascadedtie} automate the tie with self-supervised learning and cascaded matching. All these methods output a tie, sometimes with wavelet or shift uncertainty, and stop there.
|
||||
Posteriors over the well tie exist, but in every method we found the tie is the end product. \citet{buland2003bayesianwavelet} model the mistie between seismic time and log time as latent marker shifts with a triangular prior. They estimate these shifts jointly with the wavelet by MCMC and report their posterior. \citet{gunning2006waveletextractor} estimate the wavelet jointly with check-shot and marker times (Gaussian priors, monotonicity enforced), a registration shift and a lateral positioning error per well. They obtain uncertainty from a Laplace approximation and choose the wavelet length by marginal likelihood. \citet{lim2025awsm} start from a time--depth model anchored to an interpreted horizon and a well top, sample its stretch, shift and pinch-point parameters jointly with the wavelet by parallel-tempering MCMC, and report the resulting time--depth uncertainty for 44 wells in the Midland Basin. Neither prior over time shifts nor a posterior over the time--depth relation is therefore new. In these works, however, the posterior is not used further. \citet{lim2025awsm} keep two representative samples, the median-misfit and the minimum-misfit model, and estimate angle-consistent wavelets for AVO/AVA inversion; no later step in their workflow uses the time--depth posterior. \citet{wu2017multiwelltie} tie several wells at once with smooth depth-variable shifts and give no tie uncertainty. \citet{herrera2012automatedtie} use dynamic time warping for the tie. In the published version \citep{herrera2014semiautomatic}, the warping replaces the manual stretch-and-squeeze step within bounds set by the interpreter, and is meant as a guide rather than a blind method. \citet{dacostasilva2026autotie} combine time-weighted dynamic time warping, Bayesian optimization of the tie parameters and segment-wise alignment; their abstract reports higher correlations at six wells and no tie uncertainty. Among learning-based methods, \citet{tschannen2022partialtie} estimate the wavelet with a variational network: their uncertainty is mainly in wavelet phase, and the bulk shift is found by Bayesian optimization within user-set bounds. \citet{di2023welltie} automate the tie with self-supervised learning. \citet{li2025cascadedtie} automate it without learning, by a local-similarity scan followed by refinement of the residual shifts (cascaded matching). All these methods output a tie, sometimes with wavelet or shift uncertainty, and stop there.
|
||||
|
||||
\paragraph{Learning reservoir properties from seismic with few wells.}
|
||||
Recent studies predict porosity or impedance with convolutional, recurrent or transformer networks, sometimes with physics constraints or uncertainty estimates \citep{alfarraj2019semisupervised,vashisth2022rwpinn,liu2023lowfrequency,xu2024sts,chen2024multidimensional,li2024bpinn,ntibahanana2024ensemble,corrales2024seis2rock,dou2024seismae,tao2025structural,prabowo2025f3,cordoba2025porosity,rezaei2026krigingrf,sukar2026uncertainty}. In the studies we read in full, the labels are placed on the seismic time axis by a tie that is taken as given, or, in \citet{sukar2026uncertainty}, are simulated property changes paired with synthetic 4D attribute maps from a history-matched simulation model, so that no well tie places them. \citet{xu2024sts} say so explicitly, and their augmentation shifts windows laterally, not in time. \citet{li2024bpinn} calibrate the forward model of their Bayesian physics-informed network at the wells with a well-to-seismic tie that is then fixed; their posterior is over network weights. \citet{ali2025syntheticpseudowells} name the seismic-to-well tie discrepancy as a challenge and avoid it by training on synthetic pseudo-wells. Where uncertainty is estimated, it is the uncertainty of the network or of the data noise. It does not include the uncertainty of the label timing. \citet{cordoba2025porosity} report noise-sensitivity tests, but their abstract does not mention the tie or misregistered labels. Bayesian and variational inversions give posteriors or credible intervals for porosity or impedance \citep{thiebaud2024lfc,rizzuti2024waveletflows,rizzuti2025uhr}, and a bootstrapped ensemble of networks trained on rock-physics synthetics gives a spread of elastic-property predictions \citep{lim2025bootnet}. None of these works treats the well tie as a source of uncertainty (for \citet{thiebaud2024lfc} we read the abstract only). \citet{rizzuti2025uhr} treat the wavelet as known, estimated at the trace nearest a projected cone-penetration-test site, and list bringing these logs and wavelet effects into the uncertainty framework as future work. How tie and prediction quality should be scored is itself debated: \citet{castagna2026quality} argue that the correlation coefficient does not measure the information a prediction shares with the presumed truth, synthetic seismograms or well logs, and propose information-theoretic measures, also as training losses. They note that time--depth functions are never exact and that time shifts degrade mainly the higher-frequency part of a comparison. Their measures depend only on value distributions and are therefore insensitive to small shifts, but the timing error itself is neither modelled nor carried into training; their porosity example with five training wells does not describe the tie or treat it as uncertain.
|
||||
Recent studies predict porosity or impedance with neural networks (convolutional, recurrent, transformer or fully connected) or tree ensembles, sometimes with physics constraints or uncertainty estimates \citep{alfarraj2019semisupervised,vashisth2022rwpinn,liu2023lowfrequency,xu2024sts,chen2024multidimensional,li2024bpinn,ntibahanana2024ensemble,corrales2024seis2rock,dou2024seismae,tao2025structural,prabowo2025f3,cordoba2025porosity,rezaei2026krigingrf,sukar2026uncertainty}. In the field studies we read in full that work in time, the labels are placed on the seismic time axis by a tie that is taken as given. \citet{alfarraj2019semisupervised} and \citet{vashisth2022rwpinn} use synthetic data only, and \citet{rezaei2026krigingrf} work on a depth-converted cube whose conversion is taken as given. In \citet{sukar2026uncertainty} the labels are simulated property changes paired with synthetic 4D attribute maps from a history-matched simulation model, so that no well tie places them. \citet{xu2024sts} say so explicitly, and their augmentation shifts windows laterally, not in time. \citet{li2024bpinn} calibrate the forward model of their Bayesian physics-informed network at the wells with a well-to-seismic tie that is then fixed; their posterior is over network weights. \citet{ali2025syntheticpseudowells} name the seismic-to-well tie discrepancy as a challenge and avoid it by training on synthetic pseudo-wells. Where uncertainty is estimated, it is the uncertainty of the network or of the data noise. It does not include the uncertainty of the label timing. \citet{cordoba2025porosity} report noise-sensitivity tests, but their abstract does not mention the tie or misregistered labels. Bayesian and variational inversions give posteriors or credible intervals for porosity or impedance \citep{thiebaud2024lfc,rizzuti2024waveletflows,rizzuti2025uhr}, and a bootstrapped ensemble of networks trained on rock-physics synthetics gives a spread of elastic-property predictions \citep{lim2025bootnet}. None of these works treats the well tie as a source of uncertainty (for \citet{thiebaud2024lfc} we read the abstract only). \citet{rizzuti2025uhr} treat the wavelet as known, estimated at the trace nearest a projected cone-penetration-test site, and list bringing these logs and wavelet effects into the uncertainty framework as future work. How tie and prediction quality should be scored is itself debated: \citet{castagna2026quality} argue that the correlation coefficient does not measure the information a prediction shares with the presumed truth, synthetic seismograms or well logs, and propose information-theoretic measures, also as training losses. They note that time--depth functions are never exact and that time shifts degrade mainly the higher-frequency part of a comparison. Their measures depend only on value distributions and are therefore insensitive to small shifts, but the timing error itself is neither modelled nor carried into training; their porosity example with five training wells does not describe the tie or treat it as uncertain.
|
||||
|
||||
\paragraph{Losses that tolerate temporal misalignment.}
|
||||
Soft-DTW \citep{cuturi2017softdtw} and DILATE \citep{leguen2019dilate} replace the pointwise loss with a smoothed minimum over monotone alignments. Shift-tolerant losses that take the minimum over a set of bulk lags are a simpler variant. These losses use no time anchors, no physical tie model and no prior over warps. Proposition~\ref{prop:ident} shows that, without anchors, the absolute timing they learn is not identified. Learned alignment has also been applied to seismic inputs. \citet{huff2024anglestack} train a CNN on synthetic angle stacks moveout-corrected with true and perturbed velocities and use it to align field angle stacks. There the misaligned quantities are the inputs, and the synthetic targets are aligned by construction.
|
||||
Soft-DTW \citep{cuturi2017softdtw} and DILATE \citep{leguen2019dilate} replace the pointwise loss with a smoothed minimum over monotone alignments. Shift-tolerant losses that take the minimum over a set of bulk lags are a simpler variant. These losses use no time anchors, no physical tie model and, apart from DILATE's penalty on departure from the label time axis, no prior over warps. Proposition~\ref{prop:ident} shows that, without anchors, the absolute timing that soft-DTW and the shift losses learn is not identified. Learned alignment has also been applied to seismic inputs. \citet{huff2024anglestack} train a CNN on synthetic angle stacks moveout-corrected with true and perturbed velocities and use it to align field angle stacks. There the misaligned quantities are the inputs, and the synthetic targets are aligned by construction.
|
||||
|
||||
\paragraph{Label noise and errors in variables.}
|
||||
Measurement-error models distinguish classical error, which is independent of the true value, from Berkson error, which is independent of the assigned value \citep{berkson1950two,fuller1987measurement,carroll2006measurement}. In linear regression, classical error in a covariate attenuates the fitted slope, while Berkson error leaves it unbiased and adds variance. Work on noisy labels in machine learning mostly treats corrupted class labels, with robust losses, sample selection or models of the corruption process \citep{frenay2014label,song2023noisy}. Closest to our setting, \citet{mnih2012aerial} train a network to label roads in aerial images from maps whose objects are misplaced. They model the observed map as a translated crop of the true map, marginalize the likelihood over a small set of translations whose prior is set on validation data, and fit it by expectation--maximization. Without its omission term, this is a bank of shifted labels with $\lambda = 1$ and no anchors (Section~\ref{sec:method:rml}). They also score predictions with a tolerance of three pixels, because the ground truth is itself misregistered, and suggest that their noise-robust models lost precision at low recall on one test set because that set was poorly registered. Proposition~\ref{prop:reference} states the analogous effect for band MSE.
|
||||
|
||||
@@ -6,7 +6,7 @@
|
||||
|
||||
We use the public F3 Demo 2023 release of the F3 block, Dutch sector of the North Sea, distributed by dGB Earth Sciences as an OpendTect project under a CC BY-SA 3.0 licence \citep{dgb2023f3demo}. The post-stack volume covers inlines 100--750 and crosslines 300--1250 at 4\,ms sampling. Four vertical wells have sonic (DT), density (RHOB) and effective porosity (PHIE) logs: F02-1, F03-2, F03-4 and F06-1. The release also contains seven interpreted horizons and time--depth (TD) markers at each well. All learning experiments use the window 600--1100\,ms TWT (126 samples). Tie likelihoods and anchors use the extended window 400--1300\,ms.
|
||||
|
||||
Within the target window, the amplitude spectrum around the wells and over the volume peaks near 60\,Hz with a mean frequency of 49\,Hz. The dominant period is therefore 17--20\,ms. The $-20$\,dB band of the volume spans 4--83\,Hz.
|
||||
Within the target window, the amplitude spectrum of the volume peaks near 60\,Hz (43--62\,Hz around the wells), with a mean frequency of 49\,Hz. The dominant period is therefore 17--20\,ms. The $-20$\,dB band of the volume spans 4--83\,Hz.
|
||||
|
||||
We audited the well data before any modelling. Table~\ref{tab:audit} summarizes the findings, and the paragraphs below explain them.
|
||||
|
||||
@@ -20,10 +20,10 @@ We audited the well data before any modelling. Table~\ref{tab:audit} summarizes
|
||||
\toprule
|
||||
Well & IL/XL & $\Delta t_{\mathrm{DT}}$ (ms) & change (ms) & $\max|\Delta t_{\mathrm{wlt}}|$ (ms) & $K$ & Label \\
|
||||
\midrule
|
||||
F02-1 & 362/336 & $+2 \to -44$ & 46 & 28.5 & 11 & from RHOB ($R^2=0.84$) \\
|
||||
F03-2 & 722/848 & $-3 \to -14$ & 11 & 10.2 & 9 & $-0.2018+0.0011\,\mathrm{DT}$ \\
|
||||
F03-4 & 442/1007 & $-42 \to -52$ & 10 & 9.2 & 9 & $-0.2018+0.0011\,\mathrm{DT}$ \\
|
||||
F06-1 & 244/387 & $-21 \to -66$ & 45 & 36.4 & 10 & $-0.2018+0.0011\,\mathrm{DT}$ \\
|
||||
F02-1 & 362/336 & $+2 \to -44$ & 46 & 28.6 & 11 & from RHOB ($R^2=0.84$) \\
|
||||
F03-2 & 722/848 & $-3 \to -14$ & 11 & 9.6 & 9 & $-0.2018+0.0011\,\mathrm{DT}$ \\
|
||||
F03-4 & 442/1007 & $-42 \to -52$ & 10 & 8.8 & 9 & $-0.2018+0.0011\,\mathrm{DT}$ \\
|
||||
F06-1 & 244/387 & $-21 \to -66$ & 45 & 36.5 & 10 & $-0.2018+0.0011\,\mathrm{DT}$ \\
|
||||
\bottomrule
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
@@ -32,7 +32,7 @@ F06-1 & 244/387 & $-21 \to -66$ & 45 & 36.4 & 10 & $-0.2018+0.0011\,\mathrm{DT}
|
||||
We located the wells by applying the survey's bin-to-coordinate transform to the wellhead coordinates. F02-1 and F06-1 are 3.2\,km apart, and the other pairs are 8--17\,km apart. The distance to the nearest training well therefore differs greatly between leave-one-well-out folds.
|
||||
|
||||
\paragraph{Time--depth relation.}
|
||||
Integrating the sonic from the first log sample, as is common in learning studies, gives TWT that differs from the TD markers in the window by up to 14--66\,ms, depending on the well. The difference changes with depth by 10--46\,ms (Table~\ref{tab:audit}, Fig.~\ref{fig:tddrift}). The sign is negative at depth, so sonic time is early, as expected from velocity dispersion. The two TD models distributed with the data also disagree. The OpendTect model deviates from the markers by up to 36.4\,ms. A second set of model files is offset from the check-shot tables by $+40.5$, $+40.2$, $+25.2$ and $-14.6$\,ms on average. The sign and size of this offset vary by well, and at F06-1 it changes sign with depth. A datum correction does not explain it. The ``check-shot'' tables have exactly the same depths as the markers. They are horizon-tie picks made on this seismic volume, not independent check-shot surveys. We therefore treat them as anchors with a pick uncertainty $\sigma_a$. The robust spread (MAD) of marker--horizon time differences over 18 pairs at the four wells is 6.9\,ms, and we use $\sigma_a = 7$\,ms. Each well has 9--11 anchors in the target window, 8 to about 148\,ms apart.
|
||||
Integrating the sonic from the first log sample, as is common in learning studies, gives TWT that differs from the TD markers in the window by up to 14--66\,ms, depending on the well. The difference changes with depth by 10--46\,ms (Table~\ref{tab:audit}, Fig.~\ref{fig:tddrift}). The sign is negative at depth, so sonic time is early, as expected from velocity dispersion. The two TD models distributed with the data also disagree. The OpendTect model deviates from the markers by up to 36.5\,ms. A second set of model files is offset from the check-shot tables by $+40.5$, $+40.2$, $+25.2$ and $-14.6$\,ms on average. The sign and size of this offset vary by well, and at F06-1 it changes sign with depth. A datum correction does not explain it. The ``check-shot'' tables have exactly the same depths as the markers. They are horizon-tie picks made on this seismic volume, not independent check-shot surveys. We therefore treat them as anchors with a pick uncertainty $\sigma_a$. The robust spread (MAD) of marker--horizon time differences over 18 pairs at the four wells is 6.9\,ms, and we use $\sigma_a = 7$\,ms. Each well has 9--11 anchors in the target window, 8 to about 148\,ms apart.
|
||||
|
||||
\begin{figure}[t]
|
||||
\centering
|
||||
@@ -60,7 +60,7 @@ Under the F3 warp prior, Rm5 gives the posterior width closest to F3 (Section~\r
|
||||
\paragraph{Misspecification (Experiment~3).}
|
||||
Study S2 generates the data with a simulator that departs from the model used for registration, which keeps the nominal rock physics, a statistical wavelet with a constant phase, and the warp prior of Section~\ref{sec:method:prior}. There are three axes, each at two levels (Table~\ref{tab:s2}). Rock physics: the DT intercept (matrix slowness) is scaled in each stratigraphic unit by $1 + s\zeta_u$, $\zeta_u \sim \N(0, 1)$, with $s = 0.10$ (L1, about $\pm 18\,\mu$s/m) or $0.15$ (L2). Wavelet: the phase spectrum is half (L1) or all (L2) of the minimum-phase spectrum of the nominal amplitude spectrum; a separate cell, wv\_Q, applies constant-$Q$ attenuation ($Q = 80$ from 400\,ms, with dispersion), which lowers the peak frequency from 59 to 32\,Hz across the window. Drift: the true warps are drawn with scaled prior hyperparameters (bulk-offset standard deviation $\times 3$, which exceeds the value fixed in the registration, drift standard deviation $\times 1.5$ and correlation length $\times 0.5$; L1), or with components outside the prior's family (an 8\,ms step just below Truncation plus jitter with standard deviation 1\,ms and correlation length 8\,ms; L2). The size of a seismic misspecification is measured by its model error: the RMS residual between the clean seismic and the best synthetic in the registration's model family at the true warp, divided by the RMS of the noise at R10. It is 0.23 for the nominal simulator and 1.08--1.93 for the five seismic presets.
|
||||
|
||||
The levels were chosen on development realizations 902--905. The declared target for L1 was 0.5--1.0 times the R10 noise, and both L1 levels lie above it. For the phase no milder level exists: a quarter of the minimum-phase spectrum (model error 0.62) already reduced the 90\% warp coverage to 0.25 on development data. For rock physics, milder levels changed the registration too little to be told apart, so the level was set by model error. Uniform errors in the rock-physics coefficients, a constant phase rotation and a shift of the peak frequency are absorbed by the registration's profiled amplitude and constant-phase fit; they were run on development data only, as controls. At Rm5 the noise RMS is 1.78 times that of the signal and the model errors are 0.22--0.34 of the noise, so the protocol declared in advance that registration at Rm5 should be unaffected.
|
||||
The levels were chosen on development realizations 902--905. The declared target for L1 was 0.5--1.0 times the R10 noise, and both L1 levels lie above it. For the phase no milder level exists: a quarter of the minimum-phase spectrum (model error 0.62) already reduced the 90\% warp coverage to 0.25 on development data. For rock physics, milder levels changed the registration too little to be told apart, so the level was set by model error. Uniform errors in the rock-physics coefficients, a constant phase rotation and a shift of the peak frequency are absorbed by the registration's profiled amplitude and constant-phase fit; they were run on development data only, as controls. At Rm5 the noise RMS is 1.78 times that of the signal and the model errors are 0.19--0.34 of the noise, so the protocol declared in advance that registration at Rm5 should be unaffected.
|
||||
|
||||
\subsection{Volve field}
|
||||
\label{sec:data:volve}
|
||||
@@ -71,7 +71,7 @@ The second field dataset is Volve (Norwegian North Sea), released by Equinor in
|
||||
We use the post-stack ST10010 full-angle stack (3--41$^\circ$), a 2011 depth migration converted to time, at 4\,ms sampling. Its trace headers carry an invalid time scalar that standard readers apply to the start time, which shifts every sample 8\,ms late. We use the start time of the text header (4\,ms) and checked it against five interpreted horizons: the amplitude extremum along each falls at a lag of 0 to $+2$\,ms. Trajectories come from the operator's definitive surveys; recomputing them by minimum curvature reproduces the listed TVD within 0.01\,m. The seismic input of a well is a $3\times3$ patch of traces interpolated bilinearly along the deviated path at the time given by its time--depth relation, because a vertical trace at one bin differs from the path composite by a relative RMS of 0.19--0.61 over the labelled interval. Learning uses the window 2400--2900\,ms (126 samples) and tie likelihoods the extended window 2000--3200\,ms.
|
||||
|
||||
\paragraph{Time--depth and anchors.}
|
||||
Only F-11 T2 has a zero-offset VSP. As anchors we use the operator's well picks with a TWT from the Ty Formation downwards, excluding picks flagged as not logged, not reached or faulted; each well has 4--9 such anchors within its logged sonic interval. Shallower picks are unreliable (picks at the same depth in a shared borehole differ by about 110\,ms). At reservoir level every unflagged pick lies within $\pm 10$\,ms of the corresponding interpreted horizon, and at F-11 T2 the picks lie within $-6.1$ to $+2.3$\,ms of the VSP. The pick times come from the operator's time--depth models, so they are interpretations, not measurements, as on F3. Time is vertical time: DT is integrated over TVD and calibrated to the anchors by stretching between them. At F-11 T2 this marker-calibrated sonic lies within $-2.4$ to $-0.8$\,ms of the VSP over the labelled interval. We keep $\sigma_a = 7$\,ms from F3; it is not estimated on Volve.
|
||||
Of the six wells, only F-11 T2 has a zero-offset VSP. As anchors we use the operator's well picks with a TWT from the Ty Formation downwards, excluding picks flagged as not logged, not reached or faulted; each well has 4--9 such anchors within its logged sonic interval. Shallower picks are unreliable (picks at the same depth in a shared borehole differ by about 110\,ms). At reservoir level every unflagged pick lies within $\pm 10$\,ms of the corresponding interpreted horizon, and at F-11 T2 the picks lie within $-6.1$ to $+2.3$\,ms of the VSP. The pick times come from the operator's time--depth models, so they are interpretations, not measurements, as on F3. Time is vertical time: DT is integrated over TVD and calibrated to the anchors by stretching between them. At F-11 T2 this marker-calibrated sonic lies within $-2.4$ to $-0.8$\,ms of the VSP over the labelled interval. We keep $\sigma_a = 7$\,ms from F3; it is not estimated on Volve.
|
||||
|
||||
\paragraph{Labels.}
|
||||
PHIF is used only where DT is valid, which leaves 16--37 labelled 4\,ms samples per well (150 in total) at 2509--2819\,ms. The labelled runs lie 25--179\,m below the deepest anchor, so their timing depends on the drift of the sonic below it. They are shorter than one period at 6\,Hz, so the band split used on F3 is undefined here. The well means of PHIF range from 8.5\,p.u.\ at F-1 to 17.0\,p.u.\ at F-12, against standard deviations of 3.3--6.0\,p.u.\ within wells.
|
||||
|
||||
@@ -4,7 +4,7 @@
|
||||
This section asks what a registration error in the training labels does to a learned predictor and to its evaluation. Section~\ref{sec:theory:blur} shows that independent timing errors blur the optimal predictor, and Section~\ref{sec:theory:ident} that without anchors absolute timing is not identified. Section~\ref{sec:theory:post} distinguishes the two error structures of an estimated tie and bounds what a bank of posterior labels can gain. Sections~\ref{sec:theory:cov} and~\ref{sec:theory:ref} relate the error to the coverage of predictive intervals and to the bias of scoring against a misregistered reference. Proofs are in Appendix~\ref{app:proofs}.
|
||||
|
||||
\paragraph{Notation.}
|
||||
$t$ is seismic two-way time, $X$ the seismic input around a well, and $y(t)$ the label under correct registration. $\delta(t)$ is the registration error, and the observed label is $\tilde y(t) = y(t + \delta(t))$. The oracle predictor is $m(t) = \E[y(t)\mid X]$, the MSE-optimal predictor under correct labels. The Fourier transform is $\hat g(f) = \int g(t)\,e^{-i2\pi f t}\dd t$, and $T_\beta h(t) = h(t-\beta)$ is a time shift. $S_a$ is the power spectrum of $a$. The seismic band is $|f| \ge f_c$ with $f_c = 6$\,Hz, and $B$ is the corresponding high-pass operator, with $a_b = Ba$. In the experiments $B$ is a zero-phase fourth-order Butterworth filter. Its response is real and non-negative, so every result below holds with $S$ replaced by $|H_B|^2 S$. Spectral statements assume second-order stationarity in $t$, which is a working assumption for well logs.
|
||||
$t$ is seismic two-way time, $X$ the seismic input around a well, and $y(t)$ the label under correct registration. $\delta(t)$ is the registration error, and the observed label is $\tilde y(t) = y(t + \delta(t))$. The oracle predictor is $m(t) = \E[y(t)\mid X]$, the MSE-optimal predictor under correct labels. The Fourier transform is $\hat g(f) = \int g(t)\,e^{-i2\pi f t}\dd t$, and $T_\beta h(t) = h(t-\beta)$ is a time shift. $S_a$ is the power spectrum of $a$. The seismic band is $|f| \ge f_c$ with $f_c = 6$\,Hz, and $B$ is the corresponding high-pass operator, with $a_b = Ba$. In the experiments $B$ is a fourth-order Butterworth filter applied forward and backward (zero phase). Its response is real and non-negative, so every result below holds with $S$ replaced by $|H_B|^2 S$. Spectral statements assume second-order stationarity in $t$, which is a working assumption for well logs.
|
||||
|
||||
\subsection{Misregistered labels blur the optimal predictor}
|
||||
\label{sec:theory:blur}
|
||||
|
||||
@@ -11,9 +11,9 @@ For well $w$ with depth logs $\phi_w(z)$, $\mathrm{DT}_w(z)$ and $\rho_w(z)$, th
|
||||
t_w(z; b_w, g_w) = t_{w,\mathrm{ref}} + b_w + 2\int_{z_{\mathrm{ref}}}^{z} \mathrm{DT}_w(u)\, e^{g_w(u)}\dd u .
|
||||
\label{eq:warp}
|
||||
\end{equation}
|
||||
The log-slowness correction $g_w$ describes sonic--seismic drift from dispersion, tool effects or washouts. Because $e^{g} > 0$, the map is monotone by construction. $b_w \sim \N(0, \sigma_b^2)$ is a bulk offset. The prior on $g_w$ is a Gaussian process with constant mean $m_g$ and a Mat\'ern-3/2 kernel with scale $\sigma_g$ and length $\ell$. The hyperparameters $(m_g, \sigma_g, \ell)$ are fitted by type-II maximum likelihood on the anchors of the training wells only. $\sigma_a$ and $\sigma_b$ are fixed. Anchors are observed as $t_{wk} = t_w(z_{wk}) + \varepsilon_{wk}$ with $\varepsilon_{wk} \sim \N(0, \sigma_a^2)$. On F3, \eqref{eq:warp} has an important consequence: the same sonic log produces both the label and the time axis, so label and registration are coupled.
|
||||
The log-slowness correction $g_w$ describes sonic--seismic drift from dispersion, tool effects or washouts. Because $e^{g} > 0$, the map is monotone by construction. $b_w \sim \N(0, \sigma_b^2)$ is a bulk offset. The prior on $g_w$ is a Gaussian process with constant mean $m_g$ and a Mat\'ern-3/2 kernel with scale $\sigma_g$ and length $\ell$. The hyperparameters $(m_g, \sigma_g, \ell)$ are fitted by type-II maximum a posteriori estimation, with log-normal hyperpriors on $\sigma_g$ and $\ell$, on the anchors of the training wells only. $\sigma_a = 7$\,ms and $\sigma_b = 50$\,ms are fixed. Anchors are observed as $t_{wk} = t_w(z_{wk}) + \varepsilon_{wk}$ with $\varepsilon_{wk} \sim \N(0, \sigma_a^2)$. On F3, \eqref{eq:warp} has an important consequence: the same sonic log produces both the label and the time axis, so label and registration are coupled.
|
||||
|
||||
Fitted to the F3 anchors, the prior has $m_g = 0.014$, $\sigma_g = 0.10$ and $\ell = 71$\,ms. The fitted bulk spread is $\sigma_b = 19$\,ms. In leave-one-anchor-out tests, 87\% of held-out anchors lie inside the 90\% predictive interval. The synthetic benchmark draws its true warps from this fitted prior (Section~\ref{sec:data:d2}). Type-II maximum likelihood for $\sigma_a$ on F3 gives 0.4\,ms. This value is not reliable, because it treats the markers as exact: they are picks on the same seismic. We therefore use the empirical spread $\sigma_a = 7$\,ms (Section~\ref{sec:data:f3}). On F3, $\sigma_a$ is not identifiable from the data at hand.
|
||||
A separate type-II maximum-likelihood fit of all five hyperparameters to the F3 anchors gives $m_g = 0.014$, $\sigma_g = 0.10$, $\ell = 71$\,ms and a bulk spread $\sigma_b = 19$\,ms. In leave-one-anchor-out tests, 87\% of held-out anchors lie inside the 90\% predictive interval. The synthetic benchmark draws its true warps from this fitted prior (Section~\ref{sec:data:d2}). The same fit gives $\sigma_a = 0.4$\,ms. This value is not reliable, because it treats the markers as exact: they are picks on the same seismic. We therefore use the empirical spread $\sigma_a = 7$\,ms (Section~\ref{sec:data:f3}). On F3, $\sigma_a$ is not identifiable from the data at hand.
|
||||
|
||||
\subsection{Physical tie likelihood}
|
||||
\label{sec:method:tie}
|
||||
@@ -31,7 +31,7 @@ where $\mathbf r_w$ is the reflectivity computed from acoustic impedance $\rho_w
|
||||
We draw $S = 64$ warps per well from the anchor-conditioned posterior. The proposal is a Laplace (Gauss--Newton) approximation, refined by elliptical slice sampling \citep{murray2010ess}. Physical weights $\pi_s \propto p(\mathbf s_w\mid u^{(s)})^{\gamma}$ use the largest $\gamma$ that keeps the effective sample size at least $S/4$.
|
||||
|
||||
\paragraph{Sequential Monte Carlo posterior (Experiment~2).}
|
||||
Importance weights over 64 anchor-conditioned samples cannot move mass to warps that the anchor posterior rarely proposes. In development runs the weighted posterior did not contract to the true warp (Section~\ref{sec:exp:diag}). The second posterior therefore uses tempered sequential Monte Carlo. We introduced it only after the first pre-registered comparison had failed, so it is a deviation from the original protocol, and we report it as one (Section~\ref{sec:exp:diag}). It starts from $P = 1024$ anchor-posterior samples and targets $p(u\mid \text{anchors})\, p(\mathbf s_w\mid u, \psi)^{\gamma}$. The tempering exponent rises from 0 to $\gamma$ in adaptive steps that keep the effective sample size at least $P/2$. Each step uses systematic resampling followed by eight elliptical slice moves. Before the trial we registered a stability criterion: the 95th percentile over $t$ of the difference between mean warps of independent runs must not exceed 0.5\,ms. $P = 1024$ meets it at $c = 1$ on development data. At $c = 2$ the posterior is multimodal and the mean warp is unstable under every configuration we tried. We summarize posterior width by $\sigpost = w_{90}/3.29$, where $w_{90}$ is the 90\% interval width of $\tau(t)$ averaged over the main window and the training wells. No labels are used to compute it.
|
||||
Importance weights over 64 anchor-conditioned samples cannot move mass to warps that the anchor posterior rarely proposes. In development runs the weighted posterior did not contract to the true warp (Section~\ref{sec:exp:diag}). The second posterior therefore uses tempered sequential Monte Carlo. We introduced it only after the first pre-registered comparison had failed, so it is a deviation from the original protocol, and we report it as one (Section~\ref{sec:exp:diag}). It starts from $P = 1024$ anchor-posterior samples and targets $p(u\mid \text{anchors})\, p(\mathbf s_w\mid u, \psi)^{\gamma}$. The tempering exponent rises from 0 to $\gamma$ in adaptive steps that keep the effective sample size at least $P/2$. Each step uses systematic resampling followed by eight elliptical slice moves. Before the trial we registered a stability criterion: the 95th percentile over $t$ of the difference between mean warps of independent runs must not exceed 0.5\,ms. On development data $P = 1024$ meets it at $c = 1$ in 4 of 4 cells at SNR 10\,dB and in 3 of 4 at $-5$\,dB. At $c = 2$ the mean warp is unstable under every configuration we tried, and the posterior is often multimodal (Section~\ref{sec:exp:mech}). We summarize posterior width by $\sigpost = w_{90}/3.29$, where $w_{90}$ is the 90\% interval width of $\tau(t)$ averaged over the main window and the training wells. No labels are used to compute it.
|
||||
|
||||
\subsection{Labels for each warp}
|
||||
\label{sec:method:labels}
|
||||
@@ -55,10 +55,10 @@ The network outputs a mean $\mu_\theta$ and a standard deviation $\sigma_\theta$
|
||||
The training loss is the mean of $\RML_\lambda$ over windows and wells.
|
||||
|
||||
\paragraph{Choice of $\lambda$.}
|
||||
With $\lambda = 1$, differences between bank members are $O(n)$ and the log-sum-exp puts almost all weight on one member. Residuals are also autocorrelated, so a window holds less information than $n$ independent observations. If two members differ by $\Delta = \sum_i d_i$, and $d_i$ is a product of two zero-mean Gaussian processes with common autocorrelation $\rho$, then $\Var\Delta \approx n \Var(d)\,\tau_c$ with $\tau_c = 1 + 2\sum_{k\ge1}\rho(k)^2$. Setting $\lambda = 1/\tau_c$ gives $\lambda\Delta$ the variance of a log-likelihood difference over $n/\tau_c$ independent observations. This is the simplest magnitude adjustment of a composite likelihood \citep{pauli2011composite,ribatet2012composite}. Residuals are not available before training, so we estimate $\rho$ from the pooled autocorrelation of the high-passed training labels, truncated at the first non-positive lag. This gives $\tau_c \approx 2.7$ samples and $\lambda \approx 0.37$, nearly constant across the grid. The choice is a heuristic. We fixed it before the experiments and make no claim about it.
|
||||
With $\lambda = 1$, differences between bank members are $O(n)$ and the log-sum-exp puts almost all weight on one member. Residuals are also autocorrelated, so a window holds less information than $n$ independent observations. If two members differ by $\Delta = \sum_i d_i$, and $d_i$ is a product of two zero-mean Gaussian processes with common autocorrelation $\rho$, then $\Var\Delta \approx n \Var(d)\,\tau_c$ with $\tau_c = 1 + 2\sum_{k\ge1}\rho(k)^2$. Setting $\lambda = 1/\tau_c$ gives $\lambda\Delta$ the variance of a log-likelihood difference over $n/\tau_c$ independent observations. This is the simplest magnitude adjustment of a composite likelihood \citep{pauli2011composite,ribatet2012composite}. Residuals are not available before training, so we estimate $\rho$ from the pooled autocorrelation of the high-passed training labels, truncated at the first non-positive lag. This gives $\tau_c \approx 2.7$--$2.9$ samples and $\lambda \approx 0.36$--$0.37$, nearly constant across the grid. The choice is a heuristic. We fixed it before the experiments and make no claim about it.
|
||||
|
||||
\paragraph{Special cases.}
|
||||
The loss \eqref{eq:rml} contains the common alternatives. All five statements are exact and are checked numerically in the code's unit tests. Proofs are in Appendix~\ref{app:proofs}.
|
||||
The loss \eqref{eq:rml} contains the common alternatives. All five statements are exact and are checked numerically in the code's unit tests (the soft-DTW identity only in its single-path case). Proofs are in Appendix~\ref{app:proofs}.
|
||||
|
||||
\begin{lemma}[Point tie]
|
||||
\label{lem:s1}
|
||||
@@ -101,7 +101,7 @@ The last term does not depend on $\theta$. On the diagonal path, $\ell_A$ equals
|
||||
\subsection{Network and training}
|
||||
\label{sec:method:train}
|
||||
|
||||
All learned methods share one backbone and differ only in their labels and loss; study S4 of Experiment~3 adds a second. The input is a $3\times3$ trace patch around the well (nine channels), z-scored per channel within each well. Three dilated 1-D convolutions (kernel 5, dilations 1, 2 and 4, 64 channels) feed a two-layer bidirectional GRU. A $1\times1$ head with a $1\times1$ skip connection outputs $\mu$ and $\sigma$ (softplus, $\sigma \ge 10^{-3}$). Dropout is 0.05. We train with Adam (learning rate $5\times10^{-3}$, gradient clipping at 5) on full batches of all training wells. Losses are computed on 64-sample windows starting at samples $0, 2, \dots, 62$ of the 126-sample main window. Labels are standardized by the mean and standard deviation of the anti-aliased log over the training wells. These statistics do not depend on the tie. The number of iterations is selected separately for each method from $\{125, 250, 500, 1000, 2000\}$ by total RMSE on the development realizations; on F3 it is selected by inner validation (Appendix~\ref{sec:exp:f3}). Every method has the same candidate set, and band metrics are not used for selection. The second backbone, a TCN, has no recurrence: four dilated 1-D convolutions (kernel 5, dilations 1, 2, 4 and 8, 64 channels, ReLU, the same dropout) and the same output head without the skip connection. Its iterations were selected by the same rule on development realizations 902--905 (R10, $c = 1$). Every method selected 125, the smallest candidate, and the candidate set was not extended. Ensembles average five seeds (on F3, three inner models $\times$ five seeds), with $\mu = \overline{\mu_s}$ and $\sigma^2 = \overline{\sigma_s^2} + \Var_s \mu_s$.
|
||||
All learned methods share one backbone and differ only in their labels and loss; study S4 of Experiment~3 adds a second. The input is a $3\times3$ trace patch around the well (nine channels), z-scored per channel within each well. Three dilated 1-D convolutions (kernel 5, dilations 1, 2 and 4, 64 channels) feed a two-layer bidirectional GRU. A $1\times1$ head with a $1\times1$ skip connection outputs $\mu$ and $\sigma$ (softplus, $\sigma \ge 10^{-3}$). Dropout is 0.05. We train with Adam (learning rate $5\times10^{-3}$, gradient clipping at 5) on full batches of all training wells. Losses are computed on 64-sample windows starting at samples $0, 2, \dots, 62$ of the 126-sample main window. Labels are standardized by the mean and standard deviation of the anti-aliased log over the training wells. These statistics do not depend on the tie. The number of iterations is selected separately for each method from $\{125, 250, 500, 1000, 2000\}$ by total RMSE on the development realizations (benchmark controls inherit the budget of the method they modify; Table~\ref{tab:benchdesign}); on F3 it is selected by inner validation (Appendix~\ref{sec:exp:f3}). Every method has the same candidate set, and band metrics are not used for selection. The second backbone, a TCN, has no recurrence: four dilated 1-D convolutions (kernel 5, dilations 1, 2, 4 and 8, 64 channels, ReLU, the same dropout) and the same output head without the skip connection. Its iterations were selected by the same rule on development realizations 902--905 (R10, $c = 1$). Every method selected 125, the smallest candidate, and the candidate set was not extended. Ensembles average five seeds (on F3, three inner models $\times$ five seeds), with $\mu = \overline{\mu_s}$ and $\sigma^2 = \overline{\sigma_s^2} + \Var_s \mu_s$.
|
||||
|
||||
\subsection{Compared methods}
|
||||
\label{sec:method:baselines}
|
||||
@@ -160,4 +160,4 @@ B5 & five-seed ensemble of B3b & NLL \\
|
||||
\subsection{Metrics}
|
||||
\label{sec:method:metrics}
|
||||
|
||||
Accuracy is reported in porosity units (p.u., porosity $\times 100$). We split every trace into a low band ($|f| < f_c$) and a seismic band ($|f| \ge f_c$, $f_c = 6$\,Hz). The split uses a zero-phase fourth-order Butterworth filter. On F3, energy below 5\,Hz is 0.2--0.5\% of the total. The primary metrics are RMSE and Pearson correlation in the seismic band (band RMSE, band PCC): registration errors act there, while the low band is dominated by the trend. We also report total RMSE and PCC and the band standard-deviation ratio. Calibration is described by the coverage of central intervals at 50, 80, 90 and 95\%, the calibration error (mean absolute deviation of coverage from nominal over these levels), the Gaussian negative log-likelihood and the CRPS. Warp accuracy (synthetic only) is the RMSE of $\tau(t)$ against the true warp over the main window, together with 90\% coverage. Statistics are computed per test well and then macro-averaged. Intervals are 95\% bootstrap intervals over realizations (2000 resamples). On F3 the time samples within a well are not independent and there are only four wells. Field results are therefore descriptive, and we compute no per-sample $p$-values.
|
||||
Accuracy is reported in porosity units (p.u., porosity $\times 100$). We split every trace into a low band ($|f| < f_c$) and a seismic band ($|f| \ge f_c$, $f_c = 6$\,Hz). The split uses a fourth-order Butterworth filter applied forward and backward (zero phase). On F3, energy below 5\,Hz is 0.2--0.5\% of the total. The primary metrics are RMSE and Pearson correlation in the seismic band (band RMSE, band PCC): registration errors act there, while the low band is dominated by the trend. We also report total RMSE and PCC and the band standard-deviation ratio. Calibration is described by the coverage of central intervals at 50, 80, 90 and 95\%, the calibration error (mean absolute deviation of coverage from nominal over these levels), the Gaussian negative log-likelihood and the CRPS. Warp accuracy (synthetic only) is the RMSE of $\tau(t)$ against the true warp over the main window, together with 90\% coverage. Statistics are computed per test well and then macro-averaged. Intervals are 95\% bootstrap intervals over realizations (2000 resamples). On F3 the time samples within a well are not independent and there are only four wells. Field results are therefore descriptive, and we compute no per-sample $p$-values.
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
\section{Experiments}
|
||||
\label{sec:experiments}
|
||||
|
||||
We ran two pre-registered synthetic experiments, in order, then pre-registered field tests on F3 and Volve (Section~\ref{sec:exp:scope}; details in Appendix~\ref{app:field}), and finally a third synthetic experiment, a registration-aware benchmark designed after the field tests had failed (Section~\ref{sec:exp:bench}). Before each main run, the protocol (grid, methods, iteration budgets, pass rules) was locked by a SHA-256 hash, and the scripts refuse to run if the hash does not match. The protocols of Experiments~1 and~2 were also committed and tagged in version control before their main runs. The protocol of Experiment~3 was committed while its main runs were in progress, and the field protocols only after their runs; for these the record of timing is the time stamp inside the lock file (Section~\ref{sec:exp:bench}, Appendix~\ref{app:field}). In Experiments~1 and~2, every design choice was made on two development realizations (900 and 901), and Experiment~3 added four (902--905); development realizations are never used for results. Test labels were never used to choose a shift, checkpoint or hyperparameter.
|
||||
We ran two pre-registered synthetic experiments, in order, then pre-registered field tests on F3 and Volve (Section~\ref{sec:exp:scope}; details in Appendix~\ref{app:field}), and finally a third synthetic experiment, a registration-aware benchmark designed after the field tests had failed (Section~\ref{sec:exp:bench}). Before each main run, the protocol (grid, methods, iteration budgets, pass rules) was locked by a SHA-256 hash, and the scripts refuse to run if the hash does not match. The protocol of Experiment~2 was also committed and tagged in version control before its main runs; that of Experiment~1 was locked by hash before its main run but committed only afterwards, without a tag. The protocol of Experiment~3 was committed while its main runs were in progress, and the field protocols only after their runs; for these the record of timing is the time stamp inside the lock file (Section~\ref{sec:exp:bench}, Appendix~\ref{app:field}). In Experiments~1 and~2, every design choice was made on two development realizations (900 and 901), and Experiment~3 added four (902--905); development realizations are never used for results. Test labels were never used to choose a shift, checkpoint or hyperparameter.
|
||||
|
||||
Every synthetic comparison is decided by the same pre-registered rule. A comparison \emph{improves} if the candidate's seismic-band RMSE is at most 0.90 times that of the best competitor, \emph{or} its band PCC is at least 0.05 higher. Here ``best'' means the competitor with the smallest mean band RMSE in that cell. A cell \emph{passes} if the comparison improves in at least 4 of 5 seeds (each averaged over realizations) and in more than half of the realizations (each averaged over seeds). All cells use eight test wells.
|
||||
|
||||
@@ -12,7 +12,7 @@ Every synthetic comparison is decided by the same pre-registered rule. A compari
|
||||
SNR 10\,dB with full anchors; drift $c \in \{0, 0.5, 1, 2\}$; $N \in \{2, 4, 8, 16\}$; realizations 0--7; five seeds. The candidate was M2. The competitors were all point ties (B3a--B3d) and all anchor-free alignment losses (B4a--B4d). The gate required M2 to pass in at least 3 of the 4 cells at $c = 1$. In addition, at $c = 0$ the ratio of M2 to the best competitor had to be at most 1.02, both averaged over $N$ and for each $N$.
|
||||
|
||||
\paragraph{Result: the gate failed.}
|
||||
No cell at $c = 1$ passed. The ratio of M2 to the best competitor (B3c in every cell) was 1.045, 1.025, 1.020 and 0.985 for $N = 2$, 4, 8 and 16, with band PCC differences between $-0.018$ and $+0.003$ (Fig.~\ref{fig:p2phase}). The zero-drift guard also failed: the macro ratio was 1.039, and the per-$N$ ratios against B3d were 1.015, 1.045, 1.051 and 1.056. Table~\ref{tab:p2} gives band RMSE for every method at $c = 1$. M2 was about as good as the best point tie and B3d, and it stayed 20--24\% above the oracle. We report this verdict as it stands; nothing in the second experiment changes it.
|
||||
No cell at $c = 1$ passed. The ratio of M2 to the best competitor (B3c in every cell) was 1.045, 1.025, 1.020 and 0.985 for $N = 2$, 4, 8 and 16, with band PCC differences between $-0.018$ and $+0.003$ (Fig.~\ref{fig:p2phase}). The zero-drift guard also failed: the macro ratio was 1.039, and the per-$N$ ratios against B3d were 1.015, 1.045, 1.051 and 1.056. Table~\ref{tab:p2} gives band RMSE for every method at $c = 1$. M2 was about as good as the best point tie and B3d, and it stayed 20--25\% above the oracle. We report this verdict as it stands; nothing in the second experiment changes it.
|
||||
|
||||
\begin{figure}[t]
|
||||
\centering
|
||||
@@ -77,10 +77,10 @@ Five observation regimes (Section~\ref{sec:data:d2}); $c \in \{0, 1, 2\}$; $N \i
|
||||
\item \textbf{H2b.} Does RML on the SMC bank (\mRML) beat \mPM{} when the posterior is wide ($\sigpost \ge 1.5$\,ms)? At $N = 16$ the protocol requires that (a) at least two thirds of wide cells pass; (b) the Spearman correlation between $\sigpost$ and the ratio \mRML/\mPM{} over all cells is negative; and (c) the mean ratio over narrow cells is at most 1.02.
|
||||
\item \textbf{$\sigma_a$ scope.} H2a is repeated at R10, $c = 1$ with every method registered using $\sigma_a = 3.5$ or 14\,ms, while the data are generated with 7\,ms.
|
||||
\end{itemize}
|
||||
Cells at $c = 2$ are reported with an ``unstable posterior'' flag and are not used as primary evidence (Section~\ref{sec:method:posterior}). Calibration was not tested as a hypothesis. Development runs had shown that the seed ensembles under-cover more when trained on better labels, so the protocol made calibration descriptive only.
|
||||
Cells at $c = 2$ are reported with an ``unstable posterior'' flag and are not used as primary evidence for H2a (Section~\ref{sec:method:posterior}); the registered H2b tests include them. Calibration was not tested as a hypothesis. Development runs had shown that the seed ensembles under-cover more when trained on better labels, so the protocol made calibration descriptive only.
|
||||
|
||||
\paragraph{H2a: posterior-mean labels beat the best point tie.}
|
||||
All three full-anchor regimes passed (Table~\ref{tab:h2a}; Fig.~\ref{fig:p2rgrid} shows every method relative to the Oracle). At $c = 1$, \mPM{} reduced band RMSE relative to the best point tie by 14\% and 22\% at R10 ($N = 4$, 16), by 11\% at R0 and by 8\% at Rm5. At Rm5 the ratio stayed above 0.90 and the cells passed on band PCC ($+0.10$ and $+0.09$). Most of the gain is already present without drift. At $c = 0$ the macro ratios are 0.81, 0.85 and 0.88, against 0.78--0.92 at $c = 1$. Part of the advantage therefore comes from the seismic-conditioned, phase-estimated tie itself, not from correcting drift. When B3d is added as a competitor, H2a holds at R10 (2/2 cells; macro ratio at $c = 0$ is 0.94), holds in 1 of 2 cells at R0 and fails at Rm5 (0/2; ratios 0.98 and 0.97 against B3d). The claim that SMC labels beat the anchor posterior of Experiment~1 is therefore limited to high SNR. \mRML{} under the same rule passed all three regimes against point ties and R10 and R0 with B3d included.
|
||||
All three full-anchor regimes passed (Table~\ref{tab:h2a}; Fig.~\ref{fig:p2rgrid} shows every method relative to the Oracle). At $c = 1$, \mPM{} reduced band RMSE relative to the best point tie by 14\% and 22\% at R10 ($N = 4$, 16), by 11\% at R0 and by 8--9\% at Rm5. At Rm5 the ratio stayed above 0.90 and the cells passed on band PCC ($+0.10$ and $+0.09$). Most of the gain is already present without drift. At $c = 0$ the macro ratios are 0.81, 0.85 and 0.88, against 0.78--0.92 at $c = 1$. Part of the advantage therefore comes from the seismic-conditioned, phase-estimated tie itself, not from correcting drift. When B3d is added as a competitor, H2a holds at R10 (2/2 cells; macro ratio at $c = 0$ is 0.94), holds in 1 of 2 cells at R0 and fails at Rm5 (0/2; ratios 0.98 and 0.97 against B3d). The claim that SMC labels beat the anchor posterior of Experiment~1 is therefore limited to high SNR. \mRML{} under the same rule passed all three regimes against point ties and R10 and R0 with B3d included.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
@@ -158,12 +158,12 @@ R10tb & 2$^\dagger$ & 11.49 & 0.667 & [0.615, 0.713] & 0.634$^\ddagger$ & $<$0.0
|
||||
\begin{figure}[t]
|
||||
\centering
|
||||
\includegraphics[width=\linewidth]{p2r_h2b.pdf}
|
||||
\caption{H2b. (a) Band RMSE of \mRML{} divided by that of \mPM{} against the posterior width $\sigpost$, for every regime $\times$ $c$ $\times$ $N$ cell (filled: $N = 16$; open: $N = 4$; marker shape: drift factor $c$). Bars are 95\% bootstrap intervals over realizations. The dashed line is the pre-registered 1.5\,ms threshold for wide cells. (b) The same ratio against the registered population bound $1/B_a(\sigpost)$ for classical error, computed from Oracle predictions (Section~\ref{sec:theory:post}). Cells below the diagonal gained more than removing a classical population blur could give. The bound $1/B_b$ for Berkson error, the natural idealization for labels at the posterior-mean warp, is lower, and at $N = 16$ only three wide cells, all at $c = 1$, lie below it (Table~\ref{tab:h2b}). For R10tb at $c = 2$ the bound is evaluated at the 6\,ms edge of its grid. Cells at $c = 2$ have an unstable posterior and are not primary evidence.}
|
||||
\caption{H2b. (a) Band RMSE of \mRML{} divided by that of \mPM{} against the posterior width $\sigpost$, for every regime $\times$ $c$ $\times$ $N$ cell (filled: $N = 16$; open: $N = 4$; marker shape: drift factor $c$). Bars are 95\% bootstrap intervals over realizations. The dashed line is the pre-registered 1.5\,ms threshold for wide cells. (b) The same ratio against the registered population bound $1/B_a(\sigpost)$ for classical error, computed from Oracle predictions (Section~\ref{sec:theory:post}). Cells below the diagonal gained more than removing a classical population blur could give. The bound $1/B_b$ for Berkson error, the natural idealization for labels at the posterior-mean warp, is lower, and at $N = 16$ only three wide cells, all at $c = 1$, lie below it (Table~\ref{tab:h2b}). For R10tb at $c = 2$ the bound is evaluated at the 6\,ms edge of its grid. Cells at $c = 2$ have an unstable posterior and are not primary evidence for H2a.}
|
||||
\label{fig:h2b}
|
||||
\end{figure}
|
||||
|
||||
\paragraph{Posterior quality.}
|
||||
The SMC posterior was close to calibrated when the anchors were dense and $\sigma_a$ was correct. At $c = 1$, $N = 16$, the 90\% coverage was 0.89 at R10, 0.86 at R0 and 0.86 at Rm5. With only top and bottom anchors (R10tb) it was overconfident: warp RMSE 4.8\,ms against $\sigpost = 1.9$\,ms, with 90\% coverage 0.53. RML still gained the most in this regime. The bank covers part of the error even when its width understates it.
|
||||
When the anchors were dense and $\sigma_a$ was correct, the 90\% coverage of the SMC warp posterior was near, but below, nominal. At $c = 1$, $N = 16$, the 90\% coverage was 0.89 at R10, 0.86 at R0 and 0.86 at Rm5. With only top and bottom anchors (R10tb) it was overconfident: warp RMSE 4.8\,ms against $\sigpost = 1.9$\,ms, with 90\% coverage 0.53. RML still gained the most in this regime. The bank covers part of the error even when its width understates it.
|
||||
|
||||
\begin{figure}[t]
|
||||
\centering
|
||||
@@ -175,7 +175,7 @@ The SMC posterior was close to calibrated when the anchors were dense and $\sigm
|
||||
\paragraph{Predictive uncertainty (descriptive).}
|
||||
Every five-seed ensemble under-covered. At R10, $c = 1$, $N = 16$, the 90\% coverage was 0.79 for B5, 0.58 for \mPM-ens, 0.58 for \mRML-ens and 0.48 for Oracle-ens, with calibration errors 0.114, 0.300, 0.291 and 0.379. Ensembles trained on better labels predicted smaller $\sigma$ and covered less.
|
||||
|
||||
Table~\ref{tab:t4} examines this pattern post hoc, with the dispersion ratio $\xi$ of Section~\ref{sec:theory:cov} computed from the saved test-well predictions. Every ensemble was too narrow: $\xi$ was 0.19 for the Oracle and at most 0.66 (B5), against 1 for a matched second moment. Because $\xi_O$ is small, Proposition~\ref{prop:coverage}(a) requires only a small excess of predicted variance for a method to cover more than the Oracle. Each method had a larger $\xi$ and a higher coverage than the Oracle in 80--99\% of the 240 realization cells. The ordering follows training length as much as label quality. At R10, B3c-R had a median warp error of 3.5\,ms on the training wells, against 0.55\,ms for the SMC mean warp. It was trained for the Oracle's 500 iterations and reached the same $\xi$ as \mPM{} at 250. Over all regimes its excess over the Oracle was the smallest of any method (0.02--0.03). Most of the excess of \mPM{} and \mRML{} was already present at $c = 0$, where the median warp error of their labels was 0.34\,ms. Within the 250-iteration group, the methods with worse labels (B3d, B3c) had the larger excess. This is the direction that Proposition~\ref{prop:coverage}(b) gives for classical error, but B3d is a posterior mean, and the structure of these label errors was not tested. Training length acts on its own. On the development realizations of Experiment~1 (SNR 10, $c = 1$, $N = 16$), the 90\% coverage of single Oracle models fell from 0.47 after 125 iterations to 0.23 after 500 and 0.10 after 2000. Their mean $\sigma$ fell by a factor of five, while their RMSE varied by less than 10\%. In Experiment~2 training length and label source are confounded, so parts (b) and (c) of Proposition~\ref{prop:coverage} are not tested. A seed ensemble of a heteroscedastic network does not carry the tie posterior to the test wells. We make no calibration claim.
|
||||
Table~\ref{tab:t4} examines this pattern post hoc, with the dispersion ratio $\xi$ of Section~\ref{sec:theory:cov} computed from the saved test-well predictions. Every ensemble was too narrow: $\xi$ was 0.19 for the Oracle and at most 0.66 (B5), against 1 for a matched second moment. Because $\xi_O$ is small, Proposition~\ref{prop:coverage}(a) requires only a small excess of predicted variance for a method to cover more than the Oracle. Each method had a larger $\xi$, and a higher coverage, than the Oracle in 80--99\% of the 240 realization cells (each criterion separately). The ordering follows training length as much as label quality. At R10, B3c-R had a median warp error of 3.5\,ms on the training wells, against 0.55\,ms for the SMC mean warp. It was trained for the Oracle's 500 iterations and reached the same $\xi$ as \mPM{} at 250. Over all regimes its excess over the Oracle was the smallest of any method (0.02--0.03). Most of the excess of \mPM{} and \mRML{} was already present at $c = 0$, where the median warp error of their labels was 0.34\,ms. Within the 250-iteration group, the methods with worse labels (B3d, B3c) had the larger excess. This is the direction that Proposition~\ref{prop:coverage}(b) gives for classical error, but B3d is a posterior mean, and the structure of these label errors was not tested. Training length acts on its own. On the development realizations of Experiment~1 (SNR 10, $c = 1$, $N = 16$), the 90\% coverage of single Oracle models fell from 0.47 after 125 iterations to 0.23 after 500 and 0.10 after 2000. Their mean $\sigma$ fell by a factor of five, while their RMSE varied by less than 10\%. In Experiment~2 training length and label source are confounded, so parts (b) and (c) of Proposition~\ref{prop:coverage} are not tested. A seed ensemble of a heteroscedastic network does not carry the tie posterior to the test wells. We make no calibration claim.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
@@ -205,31 +205,31 @@ B5 & 125 & 1.10 & 1.36 & 0.662 & 0.79 & 0.199 & 0.199 & 0.179 \\
|
||||
We examined five possible sources of the H2b gain on the Experiment~2 bank (realizations 8--15). The tests and their readings were declared in a file whose hash was recorded before any computation. The analysis is exploratory. It uses the test realizations, and the post hoc ratios and both bounds of Section~\ref{sec:exp:p2r} (at $\sigpost$ and at the warp error, with the 60\,Hz and cross-spectral variants) had been inspected before the declaration. Retraining for the analysis reproduced the registered runs exactly (10\,560 rows, maximum deviation 0). Unless stated otherwise, the cells are the eight wide cells at $N = 16$ (R0, R0h, R10tb and Rm5 at $c \in \{1, 2\}$).
|
||||
|
||||
\paragraph{(iv) The error of the mean warp is Berkson at $c = 1$.}
|
||||
For the bulk offset of each training well, referred to the anchor tie, structure (b) predicts zero correlation between the error of \mPM{} and its estimate, and a negative correlation between the error and the true offset; structure (a) predicts the reverse (Section~\ref{sec:theory:post}). In all four wide cells at $c = 1$ the first correlation was near zero ($0.017$, $-0.035$, $-0.027$ and $-0.052$, each 95\% interval containing 0; pooled $-0.026$ $[-0.124, 0.072]$) and the second was $-0.44$ to $-0.77$. The estimated offsets were less dispersed than the true ones (variance ratio 0.41--0.81), as shrinkage of type (b) implies. At $c = 2$ neither structure fitted, and for B3c-R the anchor-referenced test is not clean, so we draw no structural conclusion for either. The bound that applies to \mPM{} at $c = 1$ is therefore $1/B_b$. Against it, the H2b ratio was lower only at R0 (0.967 against 0.982), R0h (0.970 against 0.972) and R10tb (0.890 against 0.893), two of these by at most 0.003, and in no cell at the measured warp error. A gain beyond the population correction of the Berkson structure is not established.
|
||||
For the bulk offset of each training well, referred to the anchor tie, structure (b) predicts zero correlation between the error of \mPM{} and its estimate, and a negative correlation between the error and the true offset; structure (a) predicts the reverse (Section~\ref{sec:theory:post}). In all four wide cells at $c = 1$ the first correlation was near zero ($0.017$, $-0.035$, $-0.027$ and $-0.052$, each 95\% interval containing 0; pooled $-0.026$ $[-0.124, 0.072]$) and the second was $-0.44$ to $-0.77$. The estimated offsets were less dispersed than the true ones (variance ratio 0.41--0.81), as shrinkage of type (b) implies. At $c = 2$ the anchored test gave Berkson only at Rm5 and neither structure in the other three cells, and for B3c-R the anchor-referenced test is not clean, so we draw no structural conclusion for either. The bound that applies to \mPM{} at $c = 1$ is therefore $1/B_b$. Against it, the H2b ratio was lower only at R0 (0.967 against 0.982), R0h (0.970 against 0.972) and R10tb (0.890 against 0.893), two of these by less than 0.004, and in no cell at the measured warp error under the base estimator. A gain beyond the population correction of the Berkson structure is not established.
|
||||
|
||||
\paragraph{(v) A third of the Oracle gap is training length.}
|
||||
\mPM{} was retrained at the Oracle's budget of 500 iterations. At $c = 1$ the Oracle's band RMSE was then 0.949, 0.944 and 0.957 times that of \mPM{} at R0, R0h and Rm5, against 0.927, 0.919 and 0.933 at the registered budgets. Training length thus accounts for 29--35\% of the registered gap, and the remaining 4--6\% is attributable to label error. At $c = 0$ the registered gap of 1--3\% nearly vanished (0.985--1.006). \mPM{} itself improved at 500 iterations in 7 of the 8 cells (ratios 0.973--0.985), so the budget selected on development data was not optimal for it in these cells. At equal budgets \mRML{} kept a gain over \mPM{}, smaller at R0 and R0h than at the registered budgets (0.980, 0.981, 0.887 and 0.986 at $c = 1$; 0.962, 0.913, 0.687 and 0.966 at $c = 2$, in the order R0, R0h, R10tb, Rm5).
|
||||
\mPM{} was retrained at the Oracle's budget of 500 iterations. At $c = 1$ the Oracle's band RMSE was then 0.949, 0.944 and 0.957 times that of \mPM{} at R0, R0h and Rm5, against 0.927, 0.919 and 0.933 at the registered budgets. Training length thus accounts for 30--35\% of the registered gap, and the remaining 4--6\% is attributable to label error. At $c = 0$ the registered gap of 1--3\% nearly vanished (0.985--1.006). \mPM{} itself improved at 500 iterations in 7 of the 8 cells (ratios 0.973--0.985), so the budget selected on development data was not optimal for it in these cells. At equal budgets \mRML{} kept a gain over \mPM{}, smaller at R0 and R0h than at the registered budgets (0.980, 0.981, 0.887 and 0.986 at $c = 1$; 0.962, 0.913, 0.687 and 0.966 at $c = 2$, in the order R0, R0h, R10tb, Rm5).
|
||||
|
||||
\paragraph{(ii) A bank with the posterior's first two moments gets most of the gain at $c = 1$.}
|
||||
A control bank, Ctl-GP, replaces the 64 SMC particles by 64 warps $\bar u + \eta$, where $\eta$ is Gaussian with the empirical covariance of the 1024 particles (Table~\ref{tab:methods}). Its members are as wide (marginal standard deviation 0.98--0.99 of the particles') and as wrong (warp error 1.00--1.03 times the SMC members') as the SMC bank, but no member is linked to the seismic. Ctl-GP improved on \mPM{} in 7 of the 8 cells. At $c = 1$ it matched \mRML{}: the ratios to \mPM{} were 0.970 and 0.970 (R0h), 0.904 and 0.890 (R10tb), 0.984 and 0.982 (Rm5), and 0.987 $[0.972, 1.003]$ and 0.967 (R0), for Ctl-GP and \mRML{}. At $c = 2$ the SMC bank was ahead at R0 (0.969 against 0.952), R0h (0.944 against 0.904) and R10tb (0.753 against 0.667), and not at Rm5. Under the declared reading, four cells were consistent with label augmentation alone, three showed information beyond the first two moments (all at $c = 2$), and one (R0, $c = 1$) was borderline; no reading had a majority.
|
||||
\paragraph{(ii) A bank with the posterior's first two moments gets most of the gain in three of the four cells at $c = 1$.}
|
||||
A control bank, Ctl-GP, replaces the 64 SMC particles by 64 warps $\bar u + \eta$, where $\eta$ is Gaussian with the empirical covariance of the 1024 particles (Table~\ref{tab:methods}). Its members are as wide (marginal standard deviation 0.98--1.00 of the particles') and as wrong (warp error 1.00--1.02 times the SMC members') as the SMC bank, but no member is linked to the seismic. Ctl-GP improved on \mPM{} in 7 of the 8 cells. At $c = 1$ it matched \mRML{}: the ratios to \mPM{} were 0.970 and 0.970 (R0h), 0.904 and 0.890 (R10tb), 0.984 and 0.982 (Rm5), and 0.987 $[0.972, 1.003]$ and 0.967 (R0), for Ctl-GP and \mRML{}. At $c = 2$ the SMC bank was ahead at R0 (0.969 against 0.952), R0h (0.944 against 0.904) and R10tb (0.753 against 0.667), and not at Rm5. Under the declared reading, four cells were consistent with label augmentation alone, three showed information beyond the first two moments (all at $c = 2$), and one (R0, $c = 1$) was read as against label augmentation under the declared rule (Ctl-GP interval reaching 1.003); no reading had a majority.
|
||||
|
||||
\paragraph{(i) The responsibilities re-register the training labels.}
|
||||
At the end of training, the responsibility-weighted warp $\sum_s \bar r_s T_s$ was closer to the true warp than the uniform mean of the bank in all 8 cells, with 13--40\% lower warp error (for example 1.86 to 1.38\,ms at R0, $c = 1$; 4.86 to 3.05\,ms at R10tb, $c = 1$; 19.3 to 11.7\,ms at R10tb, $c = 2$). The effective number of members was 3.5--28 of 64, so at $\lambda = 1/\tau_c$ RML is not near its $\lambda \to 0$ limit. The direction was the same at two other temperatures; we make no claim about the choice of $\lambda$. This is a property of the training wells: it is necessary for re-registration to help at test wells, not sufficient.
|
||||
At the end of training, the responsibility-weighted warp $\sum_s \bar r_s T_s$ was closer to the true warp than the uniform mean of the bank in all 8 cells, with 13--39\% lower warp error (for example 1.86 to 1.38\,ms at R0, $c = 1$; 4.86 to 3.05\,ms at R10tb, $c = 1$; 19.3 to 11.7\,ms at R10tb, $c = 2$). The effective number of members was 3.5--28 of 64, so at $\lambda = 1/\tau_c$ RML is not near its $\lambda \to 0$ limit. The direction was the same at two other temperatures; we make no claim about the choice of $\lambda$. This is a property of the training wells: it is necessary for re-registration to help at test wells, not sufficient.
|
||||
|
||||
\paragraph{(iii) No evidence that multimodality drives the gain.}
|
||||
We called a training well multimodal if a two-component Gaussian mixture fitted the window-mean offsets of its particles much better than one component ($\Delta\mathrm{BIC} > 10$, modes more than 4\,ms apart, smaller weight at least 0.1). Multimodal wells were rare except at R10tb, $c = 2$ (51\% of wells) and R0h, $c = 2$ (19\%). Within cells, the gain of \mRML{} over \mPM{} was not larger in realizations with at least a quarter of multimodal wells (adjusted difference of log ratios $-0.012$ $[-0.043, 0.020]$). With any multimodal well as the criterion the difference was $-0.017$ $[-0.031, -0.0002]$, a borderline result. The split has little power because multimodality is rare outside the unstable cells.
|
||||
\paragraph{(iii) No evidence under the primary criterion that multimodality drives the gain.}
|
||||
We called a training well multimodal if a two-component Gaussian mixture fitted the window-mean offsets of its particles much better than one component ($\Delta\mathrm{BIC} > 10$, modes more than 4\,ms apart, smaller weight at least 0.1). Multimodal wells were rare except at R10tb, $c = 2$ (51\% of wells) and R0h, $c = 2$ (19\%). Within cells, the gain of \mRML{} over \mPM{} was not larger in realizations with at least a quarter of multimodal wells (adjusted difference of log ratios $-0.012$ $[-0.043, 0.020]$). With any multimodal well as the criterion the difference was $-0.017$ $[-0.031, -0.0002]$, which meets the declared criterion for evidence of (b) only marginally. The split has little power because multimodality is rare outside the unstable cells.
|
||||
|
||||
\paragraph{Reading.}
|
||||
The five tests agree on the following. At $c = 1$, the label error of \mPM{} has the Berkson structure, and against the corresponding bound the bank gain does not exceed the population correction. A bank that carries only the width and correlation of the posterior obtains most of the gain at $c = 1$, which is what label augmentation predicts; information specific to the SMC bank mattered at $c = 2$, where the posterior is unstable and often multimodal. Re-registration of the training labels occurs, but it is not needed to explain the gain at $c = 1$. Label augmentation and re-registration are both finite-sample effects, consistent with the heuristic of Section~\ref{sec:theory:post} that with few wells finite-sample effects can outweigh the population bias. None of these results is confirmatory, and none identifies a mechanism. Experiment~3 carries the control bank and the equal-budget arm across its grid as disclosed additions (Section~\ref{sec:exp:bench}).
|
||||
The five tests agree on the following. At $c = 1$, the label error of \mPM{} has the Berkson structure, and against the corresponding bound the bank gain does not exceed the population correction. A bank that carries only the width and correlation of the posterior obtains most of the gain in three of the four cells at $c = 1$, as label augmentation predicts. Information specific to the SMC bank mattered at $c = 2$, where the posterior is unstable (and, at R10tb, often multimodal). Re-registration of the training labels occurs, but it is not needed to explain the gain at $c = 1$. Label augmentation and re-registration are both finite-sample effects, consistent with the heuristic of Section~\ref{sec:theory:post} that with few wells finite-sample effects can outweigh the population bias. None of these results is confirmatory, and none identifies a mechanism. Experiment~3 carries the control bank and the equal-budget arm across its grid as disclosed additions (Section~\ref{sec:exp:bench}).
|
||||
|
||||
\subsection{Experiment 3: registration-aware benchmark}
|
||||
\label{sec:exp:bench}
|
||||
|
||||
Experiment~3 asks how far the results of Experiment~2 extend and where they stop. It has five studies (Table~\ref{tab:benchdesign}), numbered as in the protocol; S5 and S6 are the exploratory analyses of Sections~\ref{sec:exp:mech} and~\ref{sec:exp:detect}, and S7 is the released task package. S1 fills the plane of drift factor and well count in every regime. S2 generates the data with a simulator that departs from the model used for registration (Section~\ref{sec:data:d2}). S3 adds the anchor-free alignment losses B4a--B4d to the competitors of Experiment~2. S4 repeats three cells with a second backbone, a TCN (Section~\ref{sec:method:train}). S8 replaces the estimated posterior by a label error of known two-mode structure, the setting of Corollary~\ref{cor:twomode}. At each training well the bank is the true warp and the true warp shifted by $s\Delta$, with $s = \pm 1$ drawn per well and $\Delta \in \{8, 16, 32\}$\,ms. PM2 trains on the label at the midpoint, so that its error is $\pm\Delta/2$; BK2 trains on the two-member bank with RML, and HM2 on the same bank with the hard minimum (Table~\ref{tab:methods}). Corollary~\ref{cor:twomode} predicts the transfer $\cos(\pi f\Delta)$ for PM2. The bank of BK2 contains the true warp, but it is the point label shifted by $\pm\Delta/2$ with equal weights, so in the limit $\lambda \to 0$ its transfer would be $\cos^2(\pi f\Delta)$ by the same corollary. A transfer near 1 requires the responsibilities to select the member that agrees with the seismic (Remark~\ref{rem:lambda}). The protocol calls BK2 calibrated; it is calibrated only in the weaker sense that the truth is a member, not in the sense of Proposition~\ref{prop:bank}.
|
||||
Experiment~3 asks how far the results of Experiment~2 extend and where they stop. It has five studies (Table~\ref{tab:benchdesign}), numbered as in the study plan; S5 and S6 are the exploratory analyses of Sections~\ref{sec:exp:mech} and~\ref{sec:exp:detect}, and S7 is the released task package. S1 fills the plane of drift factor and well count in every regime. S2 generates the data with a simulator that departs from the model used for registration (Section~\ref{sec:data:d2}). S3 adds the anchor-free alignment losses B4a--B4d to the competitors of Experiment~2. S4 repeats six cells (three regimes, $N \in \{4, 16\}$) with a second backbone, a TCN (Section~\ref{sec:method:train}). S8 replaces the estimated posterior by a label error of known two-mode structure, the setting of Corollary~\ref{cor:twomode}. At each training well the bank is the true warp and the true warp shifted by $s\Delta$, with $s = \pm 1$ drawn per well and $\Delta \in \{8, 16, 32\}$\,ms. PM2 trains on the label at the midpoint, so that its error is $\pm\Delta/2$; BK2 trains on the two-member bank with RML, and HM2 on the same bank with the hard minimum (Table~\ref{tab:methods}). Corollary~\ref{cor:twomode} predicts the transfer $\cos(\pi f\Delta)$ for PM2. The bank of BK2 contains the true warp, but it is the point label shifted by $\pm\Delta/2$ with equal weights, so in the limit $\lambda \to 0$ its transfer would be $\cos^2(\pi f\Delta)$ by the same corollary. A transfer near 1 requires the responsibilities to select the member that agrees with the seismic (Remark~\ref{rem:lambda}). The protocol calls BK2 calibrated; it is calibrated only in the weaker sense that the truth is a member, not in the sense of Proposition~\ref{prop:bank}.
|
||||
|
||||
\begin{table}[!htbp]
|
||||
\centering
|
||||
\caption{Design of Experiment~3. All studies use test realizations 8--15, five seeds and eight test wells per realization. Cells of S1 and S3 that coincide with Experiment~2 ($c \in \{0, 1, 2\}$, $N \in \{4, 16\}$) are read from Experiment~2. Iteration budgets are those of Experiment~2; Ctl-GP, PM2 and BK2 use 250, HM2 125, and every TCN method 125.}
|
||||
\caption{Design of Experiment~3. All studies use test realizations 8--15, five seeds and eight test wells per realization. Cells of S1 and S3 that coincide with Experiment~2 ($c \in \{0, 1, 2\}$, $N \in \{4, 16\}$) are read from Experiment~2. Iteration budgets are those of Experiment~2 (for B4a--B4d, those of Experiment~1: 125, 125, 500 and 250); Ctl-GP, PM2 and BK2 use 250, HM2 125, and every TCN method 125.}
|
||||
\label{tab:benchdesign}
|
||||
\small
|
||||
\setlength{\tabcolsep}{3pt}
|
||||
@@ -247,10 +247,10 @@ S8 & two-mode error & R10, Rm5 $\times$ $c = 1$ $\times$ $N \in \{4, 16\}$ $\tim
|
||||
\end{table}
|
||||
|
||||
\paragraph{Pre-registration and deviation.}
|
||||
The protocol of Experiment~3 was locked before its main runs, with nine claims, a prediction for each, and the decision rules of Experiment~2. Comparisons with point ties use the cell rule of Experiment~2, and a claim on a regime passes as H2a does (both cells at $c = 1$ pass, with the zero-drift guard where the statement includes it). Comparisons between two label sources are decided by the rule \emph{better}: the candidate has the lower band RMSE in at least 4 of 5 seeds and in more than half of the realizations, with no margin. The nine claims yield eleven verdicts (S2-H1 gives one per axis), with no family-wise correction. The experiment was designed after Experiment~2, after the field tests and after the post hoc analyses of Section~\ref{sec:exp:p2r}, and it reuses the test realizations 8--15. Its protocol was committed to version control while the main runs were in progress; the record of timing is the time stamp inside the lock file, four minutes before the first main run. S1, S3 and S4 also reuse the SMC particles of Experiment~2, after a check that one cell (R10, realization 8, $c = 1$, $N = 4$) reproduces its particles and predictions bit for bit. Its claims are therefore extensions of Experiment~2 on the same realizations, not independent replications. The levels of S2 and the TCN budgets were chosen on four new development realizations (902--905). The rule for the TCN picked 125 iterations, the smallest candidate; the candidate set was not extended. Two arms motivated by the exploratory analysis of Section~\ref{sec:exp:mech}, which had already seen the test realizations, are disclosed additions that enter no rule: the control bank Ctl-GP in S2 and S3, and every method retrained at 500 iterations. S8-H2 was narrowed before the lock: on development data BK2 was worse than PM2 at $\Delta = 8$\,ms, and that clause became descriptive.
|
||||
The protocol of Experiment~3 was locked before its main runs, with nine claims, a prediction for each, and the decision rules of Experiment~2. Comparisons with point ties use the cell rule of Experiment~2, and a claim on a regime passes as H2a does (both cells at $c = 1$ pass, with the zero-drift guard where the statement includes it). Comparisons between two label sources are decided by the rule \emph{better}: the candidate has the lower band RMSE in at least 4 of 5 seeds and in more than half of the realizations, with no margin. The nine claims yield eleven verdicts (S2-H1 gives one per axis), with no family-wise correction. The experiment was designed after Experiment~2, after the field tests and after the post hoc analyses of Section~\ref{sec:exp:p2r}, and it reuses the test realizations 8--15. Its protocol was committed to version control while the main runs were in progress; the record of timing is the time stamp inside the lock file, four minutes before the first main run. S1, S3 and S4 also reuse the SMC particles of Experiment~2, after a check that one cell (R10, realization 8, $c = 1$, $N = 4$) reproduces its particles and predictions bit for bit. Its claims are therefore extensions of Experiment~2 on the same realizations, not independent replications. The levels of S2 and the TCN budgets were chosen on four new development realizations (902--905). The rule for the TCN picked 125 iterations, the smallest candidate; the candidate set was not extended. Two arms are disclosed additions that enter no rule. Both were motivated by the exploratory analysis of Section~\ref{sec:exp:mech}, which had already seen the test realizations: the control bank Ctl-GP in S2 and S3, and a record of every method's prediction at 500 iterations of the same training trajectories, in the cells run in Experiment~3. S8-H2 was narrowed before the lock: on development data BK2 was worse than PM2 at $\Delta = 8$\,ms, and that clause became descriptive.
|
||||
|
||||
\paragraph{Two readings of the verdicts.}
|
||||
After the runs, the locked code that extracts the verdicts was found to differ from the locked statements in three places (Table~\ref{tab:benchverdicts}). For S1-H1 it requires exactly two cells at R10, $c = 1.5$, but S1 has four values of $N$, so it returns no verdict. For S2-H1 it reports each axis but no overall verdict, which agrees with the statement (one verdict per axis). For S3-H1 it adds Ctl-GP to the competitors, whereas the statement names B3b, B3c, B3c-R and B4a--B4d. We did not edit the locked code. A separate script, outside the code hash, checks the lock and applies the statements as worded. We report both readings. They differ in conclusion only for S3-H1.
|
||||
After the runs, the locked code that extracts the verdicts was found to differ from the locked statements in three places (Table~\ref{tab:benchverdicts}). For S1-H1 it requires exactly two cells at R10, $c = 1.5$, but S1 has four values of $N$, so it returns no verdict. For S2-H1 it reports each axis but no overall verdict, which agrees with the statement (one verdict per axis). For S3-H1 it adds Ctl-GP to the competitors, whereas the statement names B3b, B3c, B3c-R and B4a--B4d. We did not edit the locked code. A separate script, outside the code hash, checks the lock and applies the statements as worded. We report both readings. As run, S1-H1 has no verdict and S2-H1 none overall; where both readings give a verdict, they differ only for S3-H1.
|
||||
|
||||
\begin{table}[!htbp]
|
||||
\centering
|
||||
@@ -300,7 +300,7 @@ Under unit-dependent rock physics, the registration was nearly unaffected: the S
|
||||
|
||||
Under a frequency-dependent wavelet phase, the registration failed. The SMC re-estimated a constant phase of 43--46$^\circ$ and its posterior collapsed onto a wrong warp: warp error 2.58 and 2.26\,ms with 90\% coverage 0.17 and 0.10, 3.3--3.6 times its width. The band RMSE of \mPM{} rose by 25\% ($N = 4$) and 50\% ($N = 16$) relative to the nominal cells, while that of B3c, a correlation tie with the statistical wavelet, rose by at most 4\%, and B3c became the best point tie. At L2 the loss was larger (\mPM{} 1.22 and 1.39 times B3c). Under attenuation (wv\_Q) the posterior kept its coverage (0.86--0.87), and the cell passed at $N = 16$ only. Under the drift presets the coverage was 0.78--0.91 (dr\_L1) and 0.67--0.70 (dr\_L2), and the ratios stayed near their nominal values; at dr\_L2, $N = 4$, the cell failed on seeds (3/5) with a ratio of 0.892.
|
||||
|
||||
At Rm5 the protocol declared a null in advance: the noise is 1.78 times the signal and buries model errors of 0.22--0.34 of the noise. The registration diagnostics stayed near their nominal values (warp error 3.1--4.1\,ms against 3.31 and 2.91\,ms; coverage 0.74--0.88 against 0.83 and 0.86), except dr\_L1, whose warp error rose by up to 40\%. Of the 14 Rm5 cells, 13 passed the H2a cell rule.
|
||||
At Rm5 the protocol declared a null in advance: the noise is 1.78 times the signal and buries model errors of 0.19--0.34 of the noise. Except under dr\_L1, whose warp error rose by up to 40\%, the registration diagnostics stayed within 22\% of their nominal values (warp error 3.1--4.0\,ms against 3.31 and 2.91\,ms; coverage 0.74--0.86 against 0.83 and 0.86); several presets exceeded the $\pm 10\%$ seen on development data. Of the 14 Rm5 cells, 13 passed the H2a cell rule.
|
||||
|
||||
S2-H2 passed: averaged over $N$, \mRML/\mPM{} was at most 1.02 for every preset and regime (0.984--1.020 at R10, 0.984--1.012 at Rm5). The bank did not harm, but in S2 it helped little. No R10 cell was wide, and \mRML{} was better than \mPM{} in 3 of the 14 R10 cells; at Rm5, where every cell was wide, it was better in 7 of 14 (ratios 0.970--1.020). \mRML/Ctl-GP was 0.985--1.009 in all 28 cells.
|
||||
|
||||
@@ -323,21 +323,21 @@ wv\_L1 & 1.08 & 2.58 / 2.26 & 0.17 / 0.10 & 1.023 & 1.042 & 1.020 & 1.00 \\
|
||||
wv\_L2 & 1.93 & 4.74 / 4.24 & 0.04 / 0.03 & 1.217 & 1.386 & 1.003 & 1.02 \\
|
||||
wv\_Q & 1.41 & 1.68 / 1.06 & 0.86 / 0.87 & 0.927 & 0.842$^\ast$ & 1.019 & 0.97 \\
|
||||
dr\_L1 & -- & 1.63 / 1.25 & 0.78 / 0.91 & 0.862$^\ast$ & 0.798$^\ast$ & 0.984 & 1.00 \\
|
||||
dr\_L2 & -- & 2.25 / 1.38 & 0.67 / 0.70 & 0.892 & 0.820$^\ast$ & 0.988 & 1.03 \\
|
||||
dr\_L2 & -- & 2.25 / 1.38 & 0.67 / 0.70 & 0.892 & 0.820$^\ast$ & 0.988 & 1.02 \\
|
||||
\bottomrule
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\paragraph{S3: anchor-free losses do not change H2a; the control bank does.}
|
||||
As worded, S3-H1 passed at R10, R0 and Rm5, and failed at R0h and R10tb, where it is descriptive. B4a--B4d were never the best competitor at $c \le 1$, so the ratios equal those of Table~\ref{tab:h2a}. They stayed behind the point ties: at R10, $c = 1$, their band RMSE was 1.36, 1.31, 0.97 and 0.98 at $N = 4$ and 1.21, 1.14, 0.82 and 0.79 at $N = 16$, against 0.94 and 0.83 for B3b and 0.61 and 0.46 for \mPM. As run, with Ctl-GP among the competitors, S3-H1 failed in every regime. At $c = 1$ Ctl-GP was the best competitor in every regime, and the ratio of \mPM{} to it was 0.99--1.02 in R10, R0 and Rm5, so no cell passed. Ctl-GP is a bank built from the same posterior, not a point tie, and the statement did not name it. The reading as run nevertheless shows that the advantage of \mPM{} does not extend to a bank with the same first two moments.
|
||||
As worded, S3-H1 passed at R10, R0 and Rm5, and failed at R0h and R10tb, where it is descriptive. B4a--B4d were never the best competitor at $c \le 1$, so the ratios equal those of Table~\ref{tab:h2a}. They stayed behind the point ties: at R10, $c = 1$, their band RMSE was 1.36, 1.31, 0.97 and 0.98 at $N = 4$ and 1.20, 1.14, 0.81 and 0.78 at $N = 16$, against 0.94 and 0.83 for B3b and 0.61 and 0.45 for \mPM. As run, with Ctl-GP among the competitors, S3-H1 failed in every regime. At $c = 1$ Ctl-GP was the best competitor in every regime, and the ratio of \mPM{} to it was 0.99--1.02 in R10, R0 and Rm5, so no cell passed. Ctl-GP is a bank built from the same posterior, not a point tie, and the statement did not name it. The reading as run nevertheless shows that the advantage of \mPM{} does not extend to a bank with the same first two moments.
|
||||
|
||||
Across the grid of S3, the control bank (T2-1) repeated the reading of Section~\ref{sec:exp:mech}. Ctl-GP was better than \mPM{} in 16 of the 30 cells by the rule \emph{better}, which has no margin; ratios below 0.975 occurred only at $c \ge 1$ in R0, R0h, R10tb and Rm5 (for example 0.954 and 0.904 at R10tb, $c = 1$), and at R10 the ratio was 0.98--1.01. \mRML{} was better than Ctl-GP at $c = 2$ in R0, R0h, R10tb (0.895 and 0.886) and, at $N = 16$, Rm5. At $c = 1$ the ratio was 0.975--1.001, and \mRML{} was better only at R0 and at R10tb with $N = 4$. Information in the SMC bank beyond its first two moments mattered where the posterior is unstable.
|
||||
Across the grid of S3, the control bank (T2-1) repeated the reading of Section~\ref{sec:exp:mech}. Ctl-GP was better than \mPM{} in 16 of the 30 cells by the rule \emph{better}, which has no margin; ratios below 0.975 occurred only at $c \ge 1$ in R0, R0h, R10tb and Rm5 (for example 0.954 and 0.904 at R10tb, $c = 1$), and at R10 the ratio was 0.98--1.01. \mRML{} was better than Ctl-GP at $c = 2$ in R0, R0h, R10tb (0.895 and 0.886) and, at $N = 16$, Rm5. At $c = 1$ the ratio was 0.975--1.001, and \mRML{} was better only at R0 and at R10tb with $N = 4$. Information in the SMC bank beyond its first two moments mattered mainly at $c = 2$, where the posterior is unstable (descriptive).
|
||||
|
||||
\paragraph{S4: the results hold with a second backbone.}
|
||||
S4-H1 and S4-H2 passed. With the TCN at R10, $c = 1$, \mPM{} reduced band RMSE relative to the best TCN point tie (B3c-R) by 16\% and 18\% (0.840 [0.787, 0.904], $\Delta\mathrm{PCC} = +0.052$; 0.823 [0.802, 0.841]). \mRML{}-TCN was better than \mPM{}-TCN at R0h (0.977 [0.968, 0.987]) and Rm5 (0.983 [0.975, 0.991]) at $N = 16$. The TCN was a weaker backbone. Its band RMSE was 0--7\% above that of the CNN--GRU at $N = 4$ and at R0h and Rm5 with $N = 16$, and 14--24\% above at R10 with $N = 16$, where the three label sources became nearly equal (Oracle 0.560, \mPM{} 0.561, \mRML{} 0.565). Outside the claims, H2a with the TCN passed at Rm5 (0.914 and 0.913, on band PCC) and failed at R0h (0.944 and 0.943).
|
||||
|
||||
\paragraph{S8: a two-mode error reverses the band, and a bank that contains the truth repairs it.}
|
||||
S8-H1 passed (Fig.~\ref{fig:bench_s8}). At R10, $\Delta = 32$\,ms, the measured transfer of PM2 relative to the Oracle, averaged over the usable frequencies in 15.6--46.9\,Hz, was $-0.70$ ($N = 4$) and $-0.49$ ($N = 16$), against $-0.69$ and $-0.49$ for $\cos(\pi f\Delta)$ over the same frequencies; its first zero crossing was at 14.6\,Hz against 15.6\,Hz in theory. At Rm5 the values were $-0.70$ and $-0.74$, against $-0.74$ and $-0.71$. S8-H2 passed in all four cells (Table~\ref{tab:s8}). At $N = 16$, BK2 reduced band RMSE relative to PM2 by 66\% and 72\% at R10 ($\Delta = 16$, 32\,ms) and by 29\% and 37\% at Rm5, and it came within 4\% of the Oracle. In the three cells at $N = 16$ with usable frequencies in the reversed band, its transfer there was 0.92--1.00, against means of 0.05--0.59 for $\cos^2(\pi f\Delta)$ at the same frequencies. BK2 thus did more than average its two members, as re-registration by the responsibilities would. HM2 was close to BK2, but its band RMSE was higher in every cell. At $\Delta = 8$\,ms, which is descriptive, BK2 was better than PM2 at $N = 16$ but not at $N = 4$.
|
||||
S8-H1 passed (Fig.~\ref{fig:bench_s8}). At R10, $\Delta = 32$\,ms, the measured transfer of PM2 relative to the Oracle, averaged over the usable frequencies in 15.6--46.9\,Hz, was $-0.70$ ($N = 4$) and $-0.49$ ($N = 16$), against $-0.69$ and $-0.49$ for $\cos(\pi f\Delta)$ over the same frequencies; its first zero crossing was at 14.6\,Hz against 15.6\,Hz in theory. At Rm5 the values were $-0.70$ and $-0.74$, against $-0.74$ and $-0.71$. S8-H2 passed in all four cells (Table~\ref{tab:s8}). At $N = 16$, BK2 reduced band RMSE relative to PM2 by 66\% and 72\% at R10 ($\Delta = 16$, 32\,ms) and by 29\% and 36\% at Rm5, and it came within 4\% of the Oracle. In a post hoc comparison over the three cells at $N = 16$ with usable frequencies in the reversed band, its transfer there was 0.92--1.00, against means of 0.05--0.59 for $\cos^2(\pi f\Delta)$ at the same frequencies. BK2 thus did more than average its two members, as re-registration by the responsibilities would. HM2 was close to BK2, but its band RMSE was higher in every cell. At $\Delta = 8$\,ms, which is descriptive, BK2 was better than PM2 at $N = 16$ but not at $N = 4$.
|
||||
|
||||
\begin{table}[!htbp]
|
||||
\centering
|
||||
@@ -367,10 +367,10 @@ Rm5 & 32 & 1.46 / 1.64 & 0.80 / 0.64 & 0.635 [0.609, 0.673]$^\ast$ & 0.82 / 0.66
|
||||
\end{figure}
|
||||
|
||||
\paragraph{Equal training budgets (disclosed).}
|
||||
We retrained every method for 500 iterations; no rule uses this arm. No result above changed direction. At R10, $c = 1.5$, \mPM/best point tie was 0.867 and 0.793. At R10, $c = 1$, it was 0.944 and 0.920 under rp\_L1 and 1.020 and 1.042 under wv\_L1, so the S2 failures are not caused by the training length. With the TCN at R10 it was 0.864 and 0.813. The bank gain changed in narrow cells: at R10, $c = 1.5$, \mRML/\mPM{} was 0.997 and 0.999, against 0.978 and 0.987 at the registered budgets. In wide cells it remained (R10tb, $c = 1.5$: 0.916 and 0.747). BK2/PM2 in S8 was unchanged within 0.01.
|
||||
Every method's training trajectory was also evaluated at 500 iterations, in the cells run in Experiment~3 (not in the cells read from Experiment~2); no rule uses this arm. No verdict-level result changed direction. The rule \emph{better} for \mRML/\mPM{} changed outcome in 14 of the 70 S1 cells evaluated, all with ratios between 0.97 and 1.01 at both budgets. At R10, $c = 1.5$, \mPM/best point tie was 0.867 and 0.793. At R10, $c = 1$, it was 0.944 and 0.920 under rp\_L1 and 1.020 and 1.042 under wv\_L1, so the S2 failures are not caused by the training length. With the TCN at R10 it was 0.864 and 0.813. The bank gain changed in narrow cells: at R10, $c = 1.5$, \mRML/\mPM{} was 0.997 and 0.999, against 0.978 and 0.987 at the registered budgets. In wide cells it remained (R10tb, $c = 1.5$: 0.916 and 0.747). BK2/PM2 in S8 changed by at most 0.013 (at most 0.01 at $\Delta \in \{16, 32\}$\,ms).
|
||||
|
||||
\paragraph{Reading.}
|
||||
At R10 the benchmark extends H2a to $c = 1.5$, to a second backbone and to a misspecified warp prior, and it locates two failures. Labels at the posterior-mean warp lose their advantage over point ties when the wavelet phase is outside the registration's model, because the posterior then collapses onto a wrong warp. Under unit-dependent rock physics their absolute gain is nearly kept, but it no longer meets the margin of the rule. The bank gain over \mPM{} grows with the number of wells and with the posterior width, and in no preset did the bank harm. With a label error of known two-mode structure, the prediction of Corollary~\ref{cor:twomode} for the midpoint label holds: it reverses the sign of the learned response in the predicted band. A two-member bank that contains the truth removes the reversal, and with 16 wells it does more than averaging could, consistent with re-registration by the responsibilities. All of this is one simulator family with F3 statistics, on eight test realizations that Experiment~2 had already used.
|
||||
At R10 the benchmark extends H2a to $c = 1.5$, to a second backbone and to the milder misspecified warp prior (dr\_L1), and it locates two failures. Labels at the posterior-mean warp lose their advantage over point ties when the wavelet phase is outside the registration's model, because the posterior then collapses onto a wrong warp. Under unit-dependent rock physics their absolute gain is nearly kept, but it no longer meets the margin of the rule. The bank gain over \mPM{} grows with the number of wells and with the posterior width, and in no preset did the bank harm. With a label error of known two-mode structure, the prediction of Corollary~\ref{cor:twomode} for the midpoint label holds: it reverses the sign of the learned response in the predicted band. A two-member bank that contains the truth removes the reversal, and with 16 wells it does more than averaging could (post hoc), consistent with re-registration by the responsibilities. All of this is one simulator family with F3 statistics, on eight test realizations that Experiment~2 had already used.
|
||||
|
||||
\subsection{Detectability of a gain at blind wells (exploratory)}
|
||||
\label{sec:exp:detect}
|
||||
@@ -411,11 +411,11 @@ Rm5, $N = 16$ & B3c-R & 0.89 & 0.92 & 0.08 & 0.51 & 0.31 & 11 & 16 & 30 & --
|
||||
\subsection{Scope: two field cases}
|
||||
\label{sec:exp:scope}
|
||||
|
||||
\paragraph{Both field gates failed.}
|
||||
We ran two field tests under locked protocols. On F3, with four wells, gate G-C required \mRML{} to have a lower band RMSE than the selected point tie at no fewer than three of the four blind wells, and macro coverage of its 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$. On Volve, with six deviated wells and a density-driven porosity label, gate G-D asked for the same at five of six wells under two hold-out schemes, with total RMSE on the labelled samples. Both gates failed. On F3, \mRML{} improved at one well of four, and coverage was 0.52 and 0.61. Its sensitivity variants (anchor uncertainty, scoring reference, band split, label) improved at one to three wells and never met the coverage condition. On Volve, \mRML{} improved at two (leave-one-well-out) and three (slot) of six wells, and coverage of the 90\% interval was 0.48 and 0.47. No method had skill at the Volve blind wells: $R^2$ was negative for every method, and a constant at the training-well mean of PHIF had a lower macro RMSE than every network (6.03 and 6.59\,p.u.\ under the two schemes, against 6.50 and 7.13\,p.u.\ for \mRML; post hoc). Appendix~\ref{app:field} gives the designs, all tables and the protocol deviations. Neither test is an independent replication. F3 also supplied the statistics and the warp prior of the synthetic generator (Section~\ref{sec:data:d2}), and the Volve test was designed after the F3 gate had failed.
|
||||
\paragraph{Neither field gate was met.}
|
||||
We ran two field tests under locked protocols. On F3, with four wells, gate G-C required \mRML{} to have a lower band RMSE than the selected point tie at no fewer than three of the four blind wells, and macro coverage of its 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$. On Volve, with six deviated wells and a density-driven porosity label, gate G-D asked for the same at five of six wells under two hold-out schemes, with total RMSE on the labelled samples. Neither gate was met (G-D had been declared descriptive, and it met neither of its claim conditions). On F3, \mRML{} improved at one well of four, and coverage was 0.52 and 0.61. Its sensitivity variants (anchor uncertainty, scoring reference, band split, label) improved at one to three wells and never met the coverage condition. On Volve, \mRML{} improved at two (leave-one-well-out) and three (slot) of six wells, and coverage of the 90\% interval was 0.48 and 0.47. No method had skill at the Volve blind wells: macro $R^2$ was negative for every method, and a constant at the training-well mean of PHIF had a lower macro RMSE than every network (6.03 and 6.59\,p.u.\ under the two schemes, against 6.50 and 7.13\,p.u.\ for \mRML; post hoc). Appendix~\ref{app:field} gives the designs, all tables and the protocol deviations. Neither test is an independent replication. F3 also supplied the statistics and the warp prior of the synthetic generator (Section~\ref{sec:data:d2}), and the Volve test was designed after the F3 gate had failed.
|
||||
|
||||
\paragraph{Neither test could have detected the effect.}
|
||||
After both gates had failed, we stated four conditions under which a field test of this kind bears on the synthetic result, and evaluated them without test labels. The thresholds of C1 and C2 were taken mechanically from Experiment~2, so the conditions are post hoc but were not tuned to the field results. (C1) The networks have blind-well skill within the range in which Experiment~2 found the effect: at inner-validation wells, a band PCC of at least 0.468 and an $R^2$ of at least 0.053, the smallest values reached by the best point tie in the cells that passed H2a, and a lower RMSE than a constant. (C2) The tie posterior is wide, $\sigpost \ge 1.5$\,ms, the threshold of H2b; this condition matters only for the comparison with \mPM. (C3) $\sigma_a$ is identified by independent time--depth data at three or more wells outside the test set, because a misset $\sigma_a$ removed the H2a advantage (Table~\ref{tab:sigmaa}). (C4) The number of blind wells reaches $N^\star$ (Table~\ref{tab:t3}). C2 held on both datasets, with median $\sigpost$ of 2.8\,ms on F3 and 4.3\,ms on Volve. C1 failed on both: band PCC at the inner-validation wells was 0.15 on F3 and 0.13 and 0.04 on Volve (leave-one-well-out and slot), and $R^2$ was 0.04, $-0.99$ and $-0.99$. C3 and C4 fail by construction. F3 has no independent time--depth data, and Volve has check shots at two wells. Both tests scored against marker-calibrated sonic ties of the test wells, whose errors are unknown. With four wells no sign test can reject, and with independent wells the gate rules pass with probability 0.31 (three of four) and 0.11 (five of six) when there is no true difference. The failure of either gate is therefore no evidence against the synthetic result, and a pass would not have been evidence for it.
|
||||
|
||||
\paragraph{Limits of field validation.}
|
||||
A dataset with more wells does not by itself remove the constraint. After the field tests we inventoried Teapot Dome (NPR-3, Wyoming; \citealp{bader2017teapot}), where 152 wells inside the 3-D survey have density logs across a common target interval. This step is post hoc and exploratory. Its conditions were declared before the data were obtained, and the alternative reference described next was declared after the inventory but before any residual or porosity value was computed. Time--depth tables exist at four wells. Three are labelled as derived from synthetic seismograms, and the fourth, a vertical seismic profile, ends above the main reservoirs. Even counting one of the three as independent, at most two wells have an independent time--depth reference, against the $3 + 11$ that C3 and C4 need at Rm5. As an alternative reference, we paired the times of two interpreted 3-D horizons at the wells with the depths of the corresponding formation tops. On 37 development wells we predicted each time from the depth with a quadratic lateral trend of average velocity, fitted by leave-one-out. The residual standard deviation was 6.75\,ms (90\% bootstrap interval over wells 4.1--9.4\,ms; robust estimate 5.0\,ms). Most of it was a bulk shift per well (6.6\,ms): the residuals of the two horizons at a well were correlated (0.85), and those of neighbouring wells were not. The shift is therefore not a smooth velocity change that the trend missed; it resembles per-well errors of datum, statics or top picks. The differential part was 2.8\,ms, and 2.5\,ms from the sonic at five wells. Every estimate exceeded the declared tolerance of 1.5\,ms, the largest grid value at which the Rm5 cell with $N = 16$ reaches a power of 0.8 with no more than the 115 remaining wells. We therefore stopped before reading any porosity value. One dataset is not a survey, but in this one the binding constraint on field validation was the error of the scoring reference, not the number of wells.
|
||||
A dataset with more wells does not by itself remove the constraint. After the field tests we inventoried Teapot Dome (NPR-3, Wyoming; \citealp{bader2017teapot}), where 152 wells inside the 3-D survey have density logs across a common target interval. This step is post hoc and exploratory. Its conditions were declared before the data were obtained, and the alternative reference described next was declared after the inventory but before any residual or porosity value was computed. Time--depth tables exist at four wells. Two are labelled as derived from a synthetic log and one from a synthetic seismogram, and the fourth, a vertical seismic profile, ends above the main reservoirs. Even counting one of the three as independent, at most two wells have an independent time--depth reference, against the $3 + 11$ that C3 and C4 need at Rm5. As an alternative reference, we paired the times of two interpreted 3-D horizons at the wells with the depths of the corresponding formation tops. On 37 development wells we predicted each time from the depth with a quadratic lateral trend of average velocity, fitted by leave-one-out. The residual standard deviation was 6.75\,ms (90\% bootstrap interval over wells 4.1--9.4\,ms; robust estimate 5.0\,ms). Most of it was a bulk shift per well (6.6\,ms): the residuals of the two horizons at a well were correlated (0.85), and those of neighbouring wells were not. The shift is therefore not a smooth velocity change that the trend missed; it resembles per-well errors of datum, statics or top picks. The differential part was 2.8\,ms, and 2.5\,ms from the sonic at five wells. Every estimate exceeded the declared tolerance of 1.5\,ms, the largest grid value at which the Rm5 cell with $N = 16$ reaches a power of 0.8 with no more than the 115 remaining wells (58 wells by the formula of the power analysis; Table~\ref{tab:t3} stops at 40). We therefore stopped before reading any porosity value. One dataset is not a survey, but in this one the binding constraint on field validation was the error of the scoring reference, not the number of wells.
|
||||
|
||||
@@ -2,7 +2,7 @@
|
||||
\label{sec:discussion}
|
||||
|
||||
\paragraph{What the synthetic experiments show.}
|
||||
The two experiments separate two questions that are easy to conflate. The first is whether the tie posterior is informative. The second is whether training on it helps. In Experiment~1 the posterior was not informative: 64 anchor-conditioned samples reweighted by tie likelihoods stayed as wide as the anchors allowed, and labels drawn from them were no better than a good correlation-based point tie. Once the posterior contracted (SMC, Experiment~2), labels at its mean beat every point tie in all three full-anchor regimes, and a bank of its samples gained further when the posterior was wide. Better registration of the training labels came first. Marginalizing over what remained then added a smaller, width-dependent gain. Neither result says that marginalization rescues a poor posterior, and Experiment~1 is direct evidence that it does not.
|
||||
The two experiments separate two questions that are easy to conflate. The first is whether the tie posterior is informative. The second is whether training on it helps. In Experiment~1 the posterior was not informative: 64 anchor-conditioned samples reweighted by tie likelihoods barely contracted (3.15 against 3.71\,ms), and labels drawn from them were no better than a good correlation-based point tie. Once the posterior contracted (SMC, Experiment~2), labels at its mean beat every point tie in all three full-anchor regimes, and a bank of its samples gained further when the posterior was wide. Better registration of the training labels came first. Marginalizing over what remained then added a smaller, width-dependent gain. Neither result says that marginalization rescues a poor posterior: in Experiment~1 marginalizing over a poor posterior improved on its mean but not on the best point tie.
|
||||
|
||||
\paragraph{Where the posterior-mean advantage stops.}
|
||||
Experiment~3 extends the advantage of \mPM{} at R10 to $c = 1.5$, to a second backbone and to a misspecified warp prior, but the misspecification study S2 shows that it depends on the registration's model. Under a frequency-dependent wavelet phase, which a constant-phase fit cannot represent, the SMC posterior concentrated on a wrong warp (90\% coverage 0.10--0.17), and its mean became a worse label than a correlation tie that uses the statistical wavelet. A posterior that is confidently wrong is worse than a cruder point tie. Under unit-dependent rock physics, registration was nearly unaffected, and the gain of \mPM{} in squared band RMSE was largely preserved, but every method became worse and the ratio missed the registered margin. The two failures call for different checks before the posterior is used on field data: the first for the phase behaviour of the wavelet over the target window, the second for the size of the label gain relative to the error of the best predictor. Averaged over the two well counts, the bank was never more than 2\% worse than \mPM{} in any preset (S2-H2).
|
||||
@@ -12,29 +12,29 @@ The theory gives a population limit, and whether the measured gains exceed it de
|
||||
|
||||
Finite-sample effects can add to this population effect or outweigh it: the label error itself is of first order, and its effect on the conditional variance that a network must absorb is of second order, against the fourth-order population distortion (Section~\ref{sec:theory:post}). Part of the gap to the Oracle is not caused by registration at all. At $c = 0$, with SMC warp errors of 0.2--0.7\,ms, the Oracle was still 1--3\% better than \mPM{}, and it was trained twice as long. Retrained at the Oracle's budget, \mPM{} closed 29--35\% of that gap at $c = 1$ (Section~\ref{sec:exp:mech}). \mRML{} closed 27--46\% of the gap between \mPM{} and the Oracle at $c = 1$, and it did not reach the Oracle in any wide cell at $N = 16$.
|
||||
|
||||
Beyond the population correction, three finite-sample mechanisms could contribute to the bank gain: label augmentation, with the learned variance absorbing the spread of the bank; re-registration of the labels by the responsibilities for $\lambda > 0$ (Remark~\ref{rem:lambda}); and a multimodal posterior, whose mean warp has a non-Gaussian error (Corollary~\ref{cor:twomode}). The exploratory analyses bear on each but identify none. A Gaussian bank with only the first two moments of the posterior obtained most of the gain at $c = 1$, as label augmentation predicts, and across the grid of Experiment~3 information specific to the SMC bank mattered mainly at $c = 2$ (Sections~\ref{sec:exp:mech} and~\ref{sec:exp:bench}). The responsibilities did re-register the training labels, and with the two-mode error of S8 a bank containing the true warp did more than averaging its members could. No evidence linked the gain to multimodality of the SMC posterior. The bank gain therefore remains an empirical regularity of this benchmark whose source is not identified.
|
||||
Beyond the population correction, three finite-sample mechanisms could contribute to the bank gain: label augmentation, with the learned variance absorbing the spread of the bank; re-registration of the labels by the responsibilities for $\lambda > 0$ (Remark~\ref{rem:lambda}); and a multimodal posterior, whose mean warp has a non-Gaussian error (Corollary~\ref{cor:twomode}). The exploratory analyses bear on each but identify none. A Gaussian bank with only the first two moments of the posterior obtained most of the gain in three of the four cells at $c = 1$, as label augmentation predicts, and across the grid of Experiment~3 information specific to the SMC bank mattered mainly at $c = 2$ (Sections~\ref{sec:exp:mech} and~\ref{sec:exp:bench}). The responsibilities did re-register the training labels, and with the two-mode error of S8 a bank containing the true warp did more than averaging its members could. Under the primary criterion, no evidence linked the gain to multimodality of the SMC posterior; a secondary criterion did so only marginally. The bank gain therefore remains an empirical regularity of this benchmark whose source is not identified.
|
||||
|
||||
\paragraph{When to use a bank rather than the posterior mean.}
|
||||
Within this benchmark the answer depends on the posterior width. When the posterior is narrow ($\sigpost < 1.5$\,ms), \mRML{} and \mPM{} are equivalent within 1\% on average, so the bank costs little and brings nothing. When the posterior is wide, because of low SNR, sparse anchors or strong drift, \mRML{} passed in all eight wide cells at $N = 16$, and over all cells at $N = 16$ the gain grew with the width (Spearman $\rho = -0.85$). The bank adds little to training once the posterior has been computed: the network is evaluated once per window, and only the likelihood is evaluated for each of the 64 labels. Experiment~3 confirms this over the full plane of drift and well count: \mRML{} was better than \mPM{} in 44 of the 52 wide cells, the eight exceptions being at $N \le 4$ and within 1\%, and in all 13 wide families its gain was larger with 16 wells than with 2. A practical rule for this benchmark is therefore to train with the bank whenever the tie posterior is wider than about 1.5\,ms. A Gaussian bank with the posterior's mean and covariance is a cheaper alternative that came within 2.5\% of the SMC bank at $c = 1$. The largest gain at $c = 1$ came with sparse anchors (R10tb), where the posterior was overconfident and the bank was narrower than the error it was meant to represent, so in that regime the bank helped without being calibrated. On real data the width cannot be checked against a true warp, and it depends on $\sigma_a$.
|
||||
Within this benchmark the answer depends on the posterior width. When the posterior is narrow ($\sigpost < 1.5$\,ms), \mRML{} and \mPM{} are equivalent within 1\% on average, so the bank costs little and brings nothing. When the posterior is wide, because of low SNR, sparse anchors or strong drift, \mRML{} passed in all eight wide cells at $N = 16$ (four at $c = 1$; the other four at $c = 2$, flagged unstable), and over all cells at $N = 16$ the gain grew with the width (Spearman $\rho = -0.85$). The bank adds little to training once the posterior has been computed: the network is evaluated once per window, and only the likelihood is evaluated for each of the 64 labels. Experiment~3 extends this over the full plane of drift and well count: \mRML{} was better than \mPM{} in 44 of the 52 wide cells, the eight exceptions being at $N \le 4$ and within 1\%, and in all 13 wide families its gain was larger with 16 wells than with 2. A practical rule for this benchmark is therefore to train with the bank whenever the tie posterior is wider than about 1.5\,ms. A Gaussian bank with the posterior's mean and covariance is an alternative that came within 2.5\% of the SMC bank at $c = 1$. The largest gain at $c = 1$ came with sparse anchors (R10tb), where the posterior was overconfident and the bank was narrower than the error it was meant to represent, so in that regime the bank helped without being calibrated. On real data the width cannot be checked against a true warp, and it depends on $\sigma_a$.
|
||||
|
||||
\paragraph{The anchor uncertainty is the main risk.}
|
||||
Every positive result of Experiment~2 assumes that $\sigma_a$ is known. Halving or doubling it removed the H2a advantage in every cell and miscalibrated the posterior in both directions (Table~\ref{tab:sigmaa}). On F3 the time--depth markers are horizon-tie picks on the same seismic. A type-II estimate treats them as exact (0.4\,ms), while the spread between markers and horizons suggests 7\,ms. The two values place F3 at opposite ends of the $\sigpost$ axis, at about 0.6\,ms (narrow, like R10) or 2.5--3.4\,ms (wide, close to Rm5), and the arms at 3.5 and 14\,ms did not change the F3 outcome (Appendix~\ref{sec:exp:f3}). The width that decides between \mPM{} and \mRML{} inherits this dependence. An estimate of $\sigma_a$ from independent time--depth data at wells outside the test set is therefore a precondition for using the tie posterior, not a refinement of it.
|
||||
Every positive result of Experiment~2 assumes that $\sigma_a$ is known. No cell passed the H2a rule when it was halved or doubled (doubling left a 7\% gain at $N = 16$ whose interval reached 1), and both changes miscalibrated the posterior in both directions (Table~\ref{tab:sigmaa}). On F3 the time--depth markers are horizon-tie picks on the same seismic. A type-II estimate treats them as exact (0.4\,ms), while the spread between markers and horizons suggests 7\,ms. The two values place F3 at opposite ends of the $\sigpost$ axis, at about 0.6\,ms (narrow, like R10) or 2.5--3.4\,ms (wide, close to Rm5), and the arms at 3.5 and 14\,ms did not change the F3 outcome (Appendix~\ref{sec:exp:f3}). The width that decides between \mPM{} and \mRML{} inherits this dependence. An estimate of $\sigma_a$ from independent time--depth data at wells outside the test set is therefore a precondition for using the tie posterior, not a refinement of it.
|
||||
|
||||
\paragraph{What a field test of registration needs.}
|
||||
Proposition~\ref{prop:reference} and the detectability analysis (Section~\ref{sec:exp:detect}) turn the field failures into four requirements. They are derived under the simulator of the benchmark. First, the scoring reference must be independent of the seismic and accurate to about 1\,ms. To leading order, the measured advantage has the sign of the true one only if the reference error is below $1/\sqrt2$ times the tie error that the comparison is meant to detect (Corollary~\ref{cor:tolerance}), and power is lost well before that point. With an exact reference, a sign test reached a power of 0.8 with 5--18 blind wells in five of the six cells. At 1\,ms it needed 11--30 wells in four cells, and at 3\,ms or more no cell reached that power with 40 wells. Check shots or a vertical seismic profile can meet this requirement once their datum and statics are reconciled with the seismic. A reference tied by synthetic--seismic matching on the same seismic cannot, because its error is not independent of the predictions. Second, the number of blind wells should follow from a power analysis at the expected effect, and the pass rule should be a test. A rule of $k$ of $n$ wells is not one: with independent wells and no true difference, three of four passes with probability 0.31 and five of six with probability 0.11, and no one-sided sign test at $\alpha = 0.05$ can reject with four wells. Third, $\sigma_a$ must be estimated outside the test set (previous paragraph). Fourth, the networks must have skill in the seismic band at blind wells before registration can matter there. The two field cases that we tested meet none of the four. Teapot Dome, the one large dataset that we inventoried, has 152 wells but fails the first and the third: at most two of its wells have an independent time--depth reference, and the best reference that we could build from horizons and formation tops had a per-well error of 5--7\,ms (Section~\ref{sec:exp:scope}).
|
||||
Proposition~\ref{prop:reference} and the detectability analysis (Section~\ref{sec:exp:detect}) turn the field failures into four requirements. They are derived under the simulator of the benchmark. First, the scoring reference must be independent of the seismic and accurate to about 1\,ms. To leading order, the measured advantage has the sign of the true one only if the reference error is below $1/\sqrt2$ times the tie error that the comparison is meant to detect (Corollary~\ref{cor:tolerance}), and power is lost well before that point. With an exact reference, a sign test reached a power of 0.8 with 5--18 blind wells in five of the six cells. At 1\,ms it needed 11--30 wells in four cells, and at 3\,ms or more no cell reached that power with 40 wells. Check shots or a vertical seismic profile can in principle meet this requirement once their datum and statics are reconciled with the seismic; we did not test their accuracy. A reference tied by synthetic--seismic matching on the same seismic cannot, because its error is not independent of the predictions. Second, the number of blind wells should follow from a power analysis at the expected effect, and the pass rule should be a test. A rule of $k$ of $n$ wells is not one: with independent wells and no true difference, three of four passes with probability 0.31 and five of six with probability 0.11, and no one-sided sign test at $\alpha = 0.05$ can reject with four wells. Third, $\sigma_a$ must be estimated outside the test set (previous paragraph). Fourth, the networks must have skill in the seismic band at blind wells before registration can matter there. The two field cases that we tested meet none of the four. Teapot Dome, the one large dataset that we inventoried, has 152 wells with density logs across its target inside the 3-D survey, but it fails the first and the third. At most two of its wells have an independent time--depth reference, and the best reference that we could build from horizons and formation tops had a residual standard deviation of 6.75\,ms (robust estimate 5.0\,ms; Section~\ref{sec:exp:scope}).
|
||||
|
||||
\paragraph{What the field cases show.}
|
||||
Both field gates failed, but in neither case was the timing of the training labels what limited the error at the blind wells. On F3 the networks followed the low-frequency trend (total PCC about 0.5) but predicted little of the seismic band. The macro difference in band RMSE between \mRML{} and B3c-R, 0.016\,p.u., was an eighth of the variation between seeds (up to 0.13\,p.u.) and smaller than the shift produced by plausible alternative scoring references (up to 0.15\,p.u.). Two contrasts with the synthetic results suggest that the F3 band score was insensitive to the timing of the labels, although we did not test this. Without anchors, band RMSE nearly doubled in the synthetic test of H4 but fell slightly on F3 (1.247 against 1.272\,p.u.). The shift-bank losses B4a and B4b, 38--53\% worse than B3b in Experiment~1, had a lower band RMSE than every point tie on F3. The F3 label is, moreover, a linear function of the sonic at three of the four wells, so label and time axis share a source, which violates (A1). On Volve, whose label is density-driven, the error was dominated by the level of porosity, whose well means span 8.5\,p.u. The tie methods changed the macro RMSE by at most 0.25\,p.u.\ out of 6--7\,p.u., and a constant at the training-well mean beat every network (Appendix~\ref{sec:exp:volve}). Neither case is evidence against the synthetic results, and neither is evidence for them. They bound the scope of the paper: its claims about learning rest on the benchmark, and its claims about the field concern what a test there would need.
|
||||
Both field gates failed, but in neither case was the timing of the training labels what limited the error at the blind wells. On F3 the networks followed the low-frequency trend (total PCC about 0.5) but predicted little of the seismic band. The macro difference in band RMSE between \mRML{} and B3c-R, 0.016\,p.u., was an eighth of the variation between seeds (up to 0.13\,p.u.) and smaller than the spread produced by plausible alternative scoring references (5--95\% range up to 0.15\,p.u.\ wide at a well). Two contrasts with the synthetic results suggest that the F3 band score was insensitive to the timing of the labels, although we did not test this. Without anchors, band RMSE nearly doubled in the synthetic test of H4 but fell slightly on F3 (1.247 against 1.272\,p.u.). The shift-bank losses B4a and B4b, 38--53\% worse than B3b in Experiment~1, had a lower band RMSE than every point tie on F3. The F3 label $\mathrm{PHIE}_{\mathrm{DT}}$ is, moreover, a linear function of the sonic at all four wells (the original PHIE at three of them), so label and time axis share a source, which violates (A1). On Volve, whose label is density-driven, the error was dominated by the level of porosity, whose well means span 8.5\,p.u. The tie methods changed the macro RMSE by at most 0.26\,p.u.\ out of 6--7\,p.u., and a constant at the training-well mean beat every network (Appendix~\ref{sec:exp:volve}). Neither case is evidence against the synthetic results, and neither is evidence for them. They bound the scope of the paper: its claims about learning rest on the benchmark, and its claims about the field concern what a test there would need.
|
||||
|
||||
\paragraph{Limitations.}
|
||||
\begin{itemize}
|
||||
\item \textbf{One simulator.} Every confirmatory result comes from one generator family, whose statistics and warp prior were estimated on F3. Experiment~3 departs from the registration's model along three axes, at two levels each; H2a held only under the misspecified warp prior, and the levels are not calibrated to any field. Lateral heterogeneity, multiples, anisotropy and non-stationary noise were not simulated.
|
||||
\item \textbf{One simulator.} Every confirmatory result comes from one generator family, whose statistics and warp prior were estimated on F3. Experiment~3 departs from the registration's model along three axes (seven presets); at R10, H2a held in both cells only under dr\_L1, the milder misspecified warp prior, and the levels are not calibrated to any field. Lateral heterogeneity, multiples, anisotropy and non-stationary noise were not simulated.
|
||||
\item \textbf{Experiment~3 is not an independent replication.} It was designed after the field tests and the post hoc analyses, and it reuses the test realizations and SMC particles of Experiment~2 (Section~\ref{sec:exp:bench}). Its locked verdict code differed from the locked statements in three places, and we report both readings; they differ in conclusion only for S3-H1.
|
||||
\item \textbf{Experiment~2 is a deviation.} It was pre-registered and run on new realizations, but it was designed after Experiment~1 had failed, and re-running was not among the options registered for that failure (Section~\ref{sec:exp:diag}).
|
||||
\item \textbf{Strong drift.} At $c = 2$ the SMC posterior was multimodal and its mean was unstable between runs. These cells are reported but are not evidence.
|
||||
\item \textbf{Strong drift.} At $c = 2$ the mean warp of the SMC posterior was unstable between runs, and the posterior was often multimodal (51\% of wells at R10tb, 19\% at R0h). These cells are reported but are not primary evidence for H2a.
|
||||
\item \textbf{Untested stresses.} Experiment~3 did not vary the anchor uncertainty, varied the bulk-offset prior only together with the other drift hyperparameters (dr\_L1), and tested cycle skipping only in the idealized form of S8, a constant two-mode error built from the true warp.
|
||||
\item \textbf{Monte Carlo variability.} At low SNR the SMC run-to-run stability criterion failed in one of four development cells at $c = 1$, mainly through the phase estimate. This variability is small relative to $\sigpost$, but it was not removed.
|
||||
\item \textbf{Uncertainty quantification.} Seed ensembles under-covered for every method ($\xi$ of 0.19--0.66 at R10, $c = 1$, $N = 16$), and more so for better labels and longer training. Because training length and label source are confounded, parts (b) and (c) of Proposition~\ref{prop:coverage} remain untested. On F3 the macro 80\% coverage of every probabilistic method was 0.38--0.52, and on Volve 0.29--0.39. Carrying the tie posterior to predictive uncertainty at a new well needs a different mechanism, for example prediction in depth through the warp posterior. We did not attempt this.
|
||||
\item \textbf{Uncertainty quantification.} Seed ensembles under-covered for every method ($\xi$ of 0.19--0.66 at R10, $c = 1$, $N = 16$), and more so for better labels and longer training. Because training length and label source are confounded, parts (b) and (c) of Proposition~\ref{prop:coverage} remain untested. On F3 the macro 80\% coverage of every registered probabilistic method (Table~\ref{tab:f3all}) was 0.38--0.52, and on Volve 0.29--0.39. Carrying the tie posterior to predictive uncertainty at a new well needs a different mechanism, for example prediction in depth through the warp posterior. We did not attempt this.
|
||||
\item \textbf{The tempering $\lambda$.} $\lambda = 1/\tau_c$ is a heuristic fixed in advance. We did not compare it with alternatives and make no claim about it.
|
||||
\item \textbf{Two backbones.} Apart from two F3 ablations (Table~\ref{tab:f3abl}), the only second backbone is the TCN of study S4, in three cells. Both claims held with it, but it was weaker and selected the smallest budget, so this is a check of robustness, not evidence of independence from the architecture. Assumption (B) of Proposition~\ref{prop:ident} holds only approximately for either backbone.
|
||||
\item \textbf{Detectability.} Section~\ref{sec:exp:detect} rescored predictions with the skill of Experiment~2 against references whose errors are smooth and independent of the predictions. Its numbers of wells hold for predictors of comparable skill. A reference tied on the same seismic adds a covariance with the predictions that we did not model.
|
||||
|
||||
@@ -3,9 +3,9 @@
|
||||
|
||||
A well tie is an uncertain estimate, yet learning workflows treat it as exact. Its error is an error in the time index of the label. Under an independence assumption, the error convolves the optimal predictor with its distribution and blurs the seismic band, and without time anchors the absolute timing of a network and its label alignment is not identified. An estimated tie can have the classical error structure, which blurs the learned predictor, or the Berkson structure, which sharpens it. A calibrated bank of posterior labels removes both biases in population, but its population gain over a point label is of fourth order in the tie error.
|
||||
|
||||
On a registration-aware synthetic benchmark calibrated to F3, the first pre-registered comparison failed because the anchor-only posterior was not informative. In the second, designed after that failure, labels at the mean of a sequential Monte Carlo tie posterior beat the best point tie by 8--22\% in seismic-band RMSE, mostly already without drift, provided that the anchor uncertainty was correctly specified. Training on the posterior bank gained further when the posterior was wide. Under the Berkson error structure that is natural for a posterior-mean tie, the gain stayed within the population limit in most cells. An exploratory test found that structure at F3-like drift, where a Gaussian bank with the first two moments of the posterior obtained most of the gain. A third experiment, designed after the field tests and run on the same test realizations, located the limits of these results. The posterior-mean advantage held at stronger drift, with a second backbone and under a misspecified warp prior. It did not hold under a frequency-dependent wavelet phase, which made the tie posterior overconfident, nor, by the registered margin, under unit-dependent rock physics. With a two-mode label error, midpoint labels reversed the sign of the learned seismic band as predicted, and a bank containing the true warp removed the reversal.
|
||||
On a registration-aware synthetic benchmark calibrated to F3, the first pre-registered comparison failed; a diagnosis on development realizations showed that its likelihood-reweighted, anchor-conditioned posterior was not informative. In the second, designed after that failure, labels at the mean of a sequential Monte Carlo tie posterior beat the best point tie by 8--22\% in seismic-band RMSE, mostly already without drift, and, in the one regime where this was tested, only when the anchor uncertainty was correctly specified. Training on the posterior bank gained further when the posterior was wide. Under the Berkson error structure that is natural for a posterior-mean tie, the gain stayed within the population limit in most cells. An exploratory test found that structure at F3-like drift, where a Gaussian bank with the first two moments of the posterior obtained most of the gain in three of four cells. A third experiment, designed after the field tests and run on the same test realizations, located the limits of these results. At R10, the posterior-mean advantage held at stronger drift ($c = 1.5$), with a second backbone and under the milder of two misspecified warp priors. It did not hold under a frequency-dependent wavelet phase, which made the tie posterior overconfident, nor, by the registered margin, under unit-dependent rock physics. With a two-mode label error, midpoint labels reversed the sign of the learned seismic band as predicted, and a bank containing the true warp removed the reversal.
|
||||
|
||||
Whether such gains hold on field data is a question that the public datasets we examined cannot answer. A blind-well comparison of tie methods needs a reference that is independent of the seismic and accurate to about 1\,ms, enough blind wells for a test with adequate power, an anchor uncertainty estimated outside the test set, and networks with skill in the seismic band. The F3 and Volve tests met none of these conditions and failed, and Teapot Dome has independent time--depth references at no more than two of its 152 wells. We claim no improvement on field data and no calibrated uncertainty. The benchmark, the locked protocols and the detectability analysis are the means to test such claims once a dataset that meets these conditions is available.
|
||||
Whether such gains hold on field data is a question that the public datasets we examined cannot answer. A blind-well comparison of tie methods needs a reference that is independent of the seismic and accurate to about 1\,ms, enough blind wells for a test with adequate power, an anchor uncertainty estimated outside the test set, and networks with skill in the seismic band. The F3 and Volve tests met none of these conditions and failed, and Teapot Dome has independent time--depth references at no more than two of the 152 wells with density logs across its target inside the 3-D survey. We claim no improvement on field data and no calibrated uncertainty. The benchmark, the locked protocols and the detectability analysis are the means to test such claims once a dataset that meets these conditions is available.
|
||||
|
||||
\paragraph{Data and code availability.}
|
||||
The F3 Demo 2023 data are available from dGB Earth Sciences through the TerraNubis portal under a CC BY-SA 3.0 licence \citep{dgb2023f3demo}. The Volve data are available from Equinor \citep{equinor2018volve}; the licence files of the release name CC BY-NC-SA 4.0, and the data owners are Equinor, ExxonMobil, Bayerngas and the Norwegian Petroleum Directorate. The Teapot Dome data (RMOTC, U.S.\ Department of Energy) are available from the Texas Data Repository \citep{bader2017teapot}. \todo{Verify the Teapot licence on the repository page at submission (recorded as CC0 in the project notes). F3 and Volve were checked on the providers' pages on 2 November 2026.} The code, locked protocols, synthetic generator configurations and the scripts that produce every table and figure are available at \todo{repository URL and archived DOI}. The derived data from which every table and figure is computed (summaries, run-level metrics, saved test predictions and the descriptive F3 porosity volume) are archived with a manifest of SHA-256 hashes at \todo{archive DOI}, in separate archives for the F3-derived and synthetic data (CC BY-SA 3.0) and for the Volve-derived data (CC BY-NC-SA 4.0). A clean-room check recomputes the summaries, verdicts, post hoc tables and figures from the code and these archives alone, without raw seismic data. The benchmark package contains 630 tasks on the test realizations 8--15 and the development realizations 900--905, each with its inputs and its hidden true warps and labels, together with the reference results of 21 methods and a scorer that applies the locked rules; it is archived at \todo{Zenodo DOI; licence inherited from F3 (CC BY-SA 3.0), to be confirmed}.
|
||||
|
||||
@@ -101,14 +101,14 @@ No band content & 1.224 & -- & -- & -- & -- & -- \\
|
||||
\end{table}
|
||||
|
||||
\paragraph{All methods.}
|
||||
Table~\ref{tab:f3all} lists every method under the nested design. B0a, B0b and B1 use the code of Table~\ref{tab:p1} and reproduce its values. The networks have higher total RMSE than in Table~\ref{tab:p1} (B3b: 3.07 against 2.82\,p.u.); here each model is trained on two wells rather than three, and its budget is chosen by inner validation. Only B4b had a lower macro band RMSE than a prediction with no seismic-band content (1.211 against 1.224\,p.u.). B0a, which has almost no band content, came within 1.3\% of that value, and every point tie, \mPM{} and \mRML{} lay above it. Band PCC did not exceed 0.22 for any network. On F3 the networks therefore predicted little of the seismic-band variation of the label, and G-C compared methods whose band errors were nearly the same size: without B3a, the 13 networks span 1.211--1.286\,p.u. The ranking also differs from the synthetic experiments. All four anchor-free losses, B4a--B4d, had lower macro band RMSE than every point tie, \mPM{} and \mRML, by up to 0.06\,p.u. Every probabilistic method under-covered. Macro coverage was 0.38--0.52 for the 80\% intervals and 0.44--0.61 for the 90\% intervals, and \mRML{} had the highest values of both.
|
||||
Table~\ref{tab:f3all} lists every method under the nested design. B0a, B0b and B1 use the code of Table~\ref{tab:p1} and reproduce its values. The networks have higher total RMSE than in Table~\ref{tab:p1} (B3b: 3.07 against 2.82\,p.u.); here each model is trained on two wells rather than three, and its budget is chosen by inner validation. Only B4b had a lower macro band RMSE than a prediction with no seismic-band content (1.211 against 1.224\,p.u.). B0a, which has almost no band content, came within 1.3\% of that value, and every point tie, \mPM{} and \mRML{} lay above it. Band PCC did not exceed 0.22 for any network in Table~\ref{tab:f3all}. On F3 the networks therefore predicted little of the seismic-band variation of the label, and G-C compared methods whose band errors were nearly the same size: without B3a, the other 12 networks span 1.211--1.286\,p.u. The ranking also differs from the synthetic experiments. All four anchor-free losses, B4a--B4d, had lower macro band RMSE than every point tie, \mPM{} and \mRML, by 0.002--0.14\,p.u.\ (up to 0.06 relative to \mPM{} and \mRML). Every probabilistic method of Table~\ref{tab:f3all} under-covered. Macro coverage was 0.38--0.52 for the 80\% intervals and 0.44--0.61 for the 90\% intervals, and \mRML{} had the highest values of both.
|
||||
|
||||
\paragraph{Same posterior, $\sigma_a$ and scoring reference.}
|
||||
The protocol prescribes four further comparisons. None can replace a G-C condition, and none was used to choose a result. Table~\ref{tab:f3sens} gives the per-well ratios. In no row did the coverage condition hold.
|
||||
(a) Against \mPM, which is trained on the mean of the same SMC posterior, \mRML{} had lower band RMSE at two wells (F02-1 and F03-4) and higher band RMSE at F03-2, by 9.3\%. Its macro band RMSE was 0.003\,p.u.\ lower.
|
||||
(a) Against \mPM, which is trained on the mean of the same SMC posterior, \mRML{} had lower band RMSE at two wells (F02-1 and F03-4) and higher band RMSE at F03-2, by 9.3\%, and at F06-1, by 1.2\%. Its macro band RMSE was 0.003\,p.u.\ lower.
|
||||
(b) With $\sigma_a = 3.5$ or 14\,ms, B3c-R, \mPM{} and \mRML{} were registered and trained again, and \mRML{} was compared with B3c-R at the same $\sigma_a$. It had lower band RMSE at one and two of the four wells, and the wells that improved were not the same in the three arms. Macro coverage was 0.47--0.48 and 0.57--0.59.
|
||||
(c) When the test well is scored against the OpendTect time--depth model instead of the marker-calibrated sonic, \mRML{} again improved only at F03-4. We also scored each method against 64 warps of the test well, drawn from an anchor-only posterior whose prior was fitted on the other three wells. The 5--95\% range of band RMSE over these references was 0.06--0.15\,p.u.\ wide for \mRML{} and for B3c-R, and the ranges of the two methods overlapped at F02-1, F03-2 and F03-4. At F06-1 they did not overlap (\mRML: 1.13--1.18\,p.u.; B3c-R: 1.04--1.11\,p.u.).
|
||||
(d) Moving the band cutoff to 5 or 8\,Hz changed no ratio by more than 0.01. With the original PHIE label, \mRML{} improved at three wells, but coverage was lower (0.45 and 0.50). In the window the two labels differ by an RMS of 3.2\,p.u.\ at F02-1 and by less than 0.02\,p.u.\ at the other wells. F02-1 is a training well in three of the four outer folds, and the ratios at those three test wells moved by up to 0.13. This shows how much a ratio near one depends on the label of a single training well. The gate is defined on $\mathrm{PHIE}_{\mathrm{DT}}$, and this row does not change its result.
|
||||
(d) Moving the band cutoff to 5 or 8\,Hz changed no ratio by more than 0.011, but at 8\,Hz \mRML{} also improved at F03-2 (2/4). With the original PHIE label, \mRML{} improved at three wells, but coverage was lower (0.45 and 0.50). In the window the two labels differ by an RMS of 3.2\,p.u.\ at F02-1 and by less than 0.02\,p.u.\ at the other wells. F02-1 is a training well in three of the four outer folds, and the ratios at those three test wells moved by up to 0.13. This shows how much a ratio near one depends on the label of a single training well. The gate is defined on $\mathrm{PHIE}_{\mathrm{DT}}$, and this row does not change its result.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
@@ -132,12 +132,12 @@ PHIE label & 0.992 & 0.911 & 1.025 & 0.943 & 3/4 & 0.45 & 0.50 \\
|
||||
\end{table}
|
||||
|
||||
\paragraph{Posterior width and anchors.}
|
||||
At $\sigma_a = 7$\,ms, $\sigpost$ of the SMC posterior ranged from 1.7 to 3.6\,ms over the 12 training wells of the six training pairs (median 2.8\,ms). Seven of the 12 values lay in the range of 2.5--3.4\,ms estimated before the run from all four wells. By the rule of Experiment~2 every pair is therefore wide ($\sigpost \ge 1.5$\,ms), the regime in which RML helped at $N = 16$. Each F3 model, however, is trained on two wells, and \mRML{} beat \mPM{} at two of the four outer wells (Table~\ref{tab:f3sens}). The width followed $\sigma_a$: it was 1.2--2.3\,ms at $\sigma_a = 3.5$\,ms and 1.8--6.2\,ms at 14\,ms. Without anchors it was 17--38\,ms at F02-1, F03-2 and F03-4, and 1.4--2.0\,ms at F06-1. The wavelet phase was poorly identified. The six phases estimated at $\sigma_a = 7$\,ms spread over an arc of 214$^\circ$. Over the phases evaluated for each pair, a window 90--120$^\circ$ wide, the summed log evidence of the two wells changed by only 1.0--5.0\,nats.
|
||||
At $\sigma_a = 7$\,ms, $\sigpost$ of the SMC posterior ranged from 1.7 to 3.6\,ms over the 12 training wells of the six training pairs (median 2.8\,ms). Seven of the 12 values lay in the range of 2.5--3.4\,ms estimated before the run from all four wells. By the rule of Experiment~2 every pair is therefore wide ($\sigpost \ge 1.5$\,ms), the regime in which RML helped at $N = 16$. Each F3 model, however, is trained on two wells, and \mRML{} beat \mPM{} at two of the four outer wells (Table~\ref{tab:f3sens}). The width followed $\sigma_a$: it was 1.2--2.3\,ms at $\sigma_a = 3.5$\,ms and 1.9--6.2\,ms at 14\,ms. Without anchors it was 17--38\,ms at F02-1, F03-2 and F03-4, and 1.4--2.0\,ms at F06-1. The wavelet phase was poorly identified. The six phases estimated at $\sigma_a = 7$\,ms spread over an arc of 214$^\circ$. Over the phases evaluated for each pair, a window 90--120$^\circ$ wide, the summed log evidence of the two wells changed by only 1.0--5.0\,nats.
|
||||
|
||||
Leave-one-anchor-out $z$-scores test the anchor prior on the outer wells. For each well, a linearized Gaussian process conditioned on the anchors alone, with hyperparameters fitted on the other three wells and pick noise $\sigma_a = 7$\,ms, predicts each anchor time from the remaining anchors of that well. Of 62 held-out anchors, 61 lay inside the 90\% interval. The mean $z^2$ was 0.21 (per well: 0.20, 0.01, 0.01 and 0.59), against an expected value of 1. The anchor prior is therefore too wide rather than too narrow, the same direction as the type-II estimate of $\sigma_a$ (0.4\,ms, Section~\ref{sec:method:prior}) and the opposite direction to the under-coverage of porosity. This check does not test the calibration of the SMC posterior, which also depends on the seismic likelihood and the wavelet phase.
|
||||
|
||||
\paragraph{Ablations (descriptive).}
|
||||
The protocol lists twelve variants of \mRML{} on $\mathrm{PHIE}_{\mathrm{DT}}$ (Table~\ref{tab:f3abl}). They were scored like every other method, but none enters G-C. M2-anchor-only trains on the 64 anchor-only warps of M1 with the same weights, so it reproduces M1 exactly. Nine of the other eleven variants had lower macro band RMSE than \mRML. The variants spanned 1.242--1.309\,p.u., about four times the gap of 0.016\,p.u.\ between \mRML{} and B3c-R. Bank size had no consistent effect: with 1, 8, 64 and 256 SMC labels, band RMSE was 1.273, 1.256, 1.272 and 1.257\,p.u. A convolutional backbone without the GRU lowered band RMSE by about 2\% for both \mRML{} (M2-TCN) and \mPM{} (B3d-Sa-TCN), so it did not change their order. Removing the anchors (M2-no-anchors) lowered band RMSE to 1.247\,p.u.\ but gave the highest total RMSE of the variants (3.23\,p.u.). M2-fixed-sigma was the only variant with coverage close to nominal (0.87 and 0.92), and this is not calibration. Its predicted standard deviation is fixed at the standard deviation of the training labels, which gave 2.9--4.3\,p.u.\ after mixing, against 1.0--2.1\,p.u.\ for \mRML. Its 80\% intervals covered every sample at F03-2 and F03-4 and 0.74 and 0.73 of the samples at F02-1 and F06-1. The macro value is an average of these, not evidence of correct width. M2-LFM adds the low-pass mean label of the training wells as an input channel. It had the lowest total RMSE of any network (2.62\,p.u., against 2.48\,p.u.\ for B0a) and the highest band RMSE of the variants (1.309\,p.u.). Its gain lies below $f_c$, where the gate does not score.
|
||||
The protocol lists twelve ablations on $\mathrm{PHIE}_{\mathrm{DT}}$, eleven of \mRML{} and one of \mPM{} (Table~\ref{tab:f3abl}). They were scored like every other method, but none enters G-C. M2-anchor-only trains on the 64 anchor-only warps of M1 with the same weights, so it reproduces M1 exactly. Nine of the other eleven variants had lower macro band RMSE than \mRML. The variants spanned 1.242--1.309\,p.u., about four times the gap of 0.016\,p.u.\ between \mRML{} and B3c-R. Bank size had no consistent effect: with 1, 8, 64 and 256 SMC labels, band RMSE was 1.273, 1.256, 1.272 and 1.257\,p.u. A convolutional backbone without the GRU lowered band RMSE by about 2\% for both \mRML{} (M2-TCN) and \mPM{} (B3d-Sa-TCN), so it did not change their order. Removing the anchors (M2-no-anchors) lowered band RMSE to 1.247\,p.u.\ but gave the highest total RMSE of the variants (3.23\,p.u.). M2-fixed-sigma was the only variant with coverage close to nominal (0.87 and 0.92), and this is not calibration. Its predicted standard deviation is fixed at the standard deviation of the training labels, which gave 2.9--4.3\,p.u.\ after mixing, against 1.0--2.1\,p.u.\ for \mRML. Its 80\% intervals covered every sample at F03-2 and F03-4 and 0.74 and 0.73 of the samples at F02-1 and F06-1. The macro value is an average of these, not evidence of correct width. M2-LFM adds the low-pass mean label of the training wells as an input channel. It had the lowest total RMSE of any network (2.62\,p.u., against 2.48\,p.u.\ for B0a) and the highest band RMSE of the variants (1.309\,p.u.). Its gain lies below $f_c$, where the gate does not score.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
@@ -189,7 +189,7 @@ The Volve test was designed on 28 October 2026, after the F3 gate had failed and
|
||||
The six wells are held out under two schemes (Section~\ref{sec:data:volve}). Under \emph{lowo}, each well is the outer test well once and the other five train. Under \emph{slot}, the whole slot group of the test well is held out, so F-1 trains on F-11 A, F-11 T2 and F-12 only; for F-12, which is alone in its slot, the two schemes coincide and its rows are identical. Within the outer training wells, each is held out once as an inner validation well. The held-out well never supplies its picks, sonic or logs to its own input. Its path is placed in time by the mean TVDSS--TWT relation of the wells it is held out from, which also moves the 3$\times$3 patch laterally along the deviated trajectory (by up to 76\,m, F-1 A under slot). Registration ($\sigma_a = 7$\,ms, $P = 1024$, $S = 64$) uses the training wells of each model only. Budgets are chosen from $\{125, 250, 500, 1000, 2000\}$ by inner-validation MSE on the labelled samples, and the prediction at the outer well is the moment-matched mixture of the inner models at the selected budget and five seeds (25 members under lowo, 15--25 under slot). The reference is the marker-calibrated vertical sonic of the test well. Gate G-D is descriptive. ``Consistent improvement'' needs \mRML{} below the selected point tie (B3b, B3c or B3c-R, by inner validation) at no fewer than five of six wells under both schemes, the F3 rule of three of four scaled up. ``Calibrated'' needs macro coverage of the 80\% and 90\% intervals within $[0.75, 0.85]$ and $[0.85, 0.95]$ under both schemes. Neither wording can override the F3 result.
|
||||
|
||||
\paragraph{Result: neither condition held.}
|
||||
Table~\ref{tab:volvegd} gives the per-well comparison. Under lowo, inner validation chose B3b at every well, and \mRML{} had lower RMSE at two wells (F-1 B by 1.1\% and F-11 T2 by 1.5\%). At the other four it was 0.4--4.6\% worse. Its macro RMSE was 6.50\,p.u.\ against 6.36\,p.u.\ for B3b. Under slot, inner validation chose B3c in the F-1 slot and B3b in the others, and \mRML{} improved at three wells. The two large ratios in that scheme, 0.85 at F-1 and 0.90 at F-1 B, are against B3c, which had the lowest inner-validation MSE in that fold but was worse than B3b at both test wells (8.04 against 7.27\,p.u.\ and 5.35 against 5.17\,p.u.); against B3b, \mRML{} is 5.8\% better at F-1 and 7.1\% better at F-1 B. Its macro RMSE under slot was 7.13\,p.u.\ against 7.32\,p.u.\ for the selected ties. Against \mPM, trained on the mean of the same posterior, \mRML{} was lower at three of six wells under lowo and four of six under slot, with macro differences of 0.02 and 0.13\,p.u. Macro coverage was 0.39 and 0.48 (lowo) and 0.35 and 0.47 (slot) for the 80\% and 90\% intervals, lower than on F3 and far below the bands. No well reached nominal coverage; the highest values were 0.68 and 0.72 at F-1 B. Nothing was changed after the test wells were scored. We make no claim of improvement and no claim of calibrated uncertainty on Volve.
|
||||
Table~\ref{tab:volvegd} gives the per-well comparison. Under lowo, inner validation chose B3b at every well, and \mRML{} had lower RMSE at two wells (F-1 B by 1.1\% and F-11 T2 by 1.5\%). At the other four it was 0.4--4.6\% worse. Its macro RMSE was 6.50\,p.u.\ against 6.36\,p.u.\ for B3b. Under slot, inner validation chose B3c in the F-1 slot and B3b in the others, and \mRML{} improved at three wells. The two large ratios in that scheme, 0.85 at F-1 and 0.90 at F-1 B, are against B3c, which had the lowest inner-validation MSE in that fold but was worse than B3b at both test wells (8.04 against 7.27\,p.u.\ and 5.35 against 5.17\,p.u.); against B3b, \mRML{} is 5.7\% better at F-1 and 7.2\% better at F-1 B. Its macro RMSE under slot was 7.13\,p.u.\ against 7.32\,p.u.\ for the selected ties. Against \mPM, trained on the mean of the same posterior, \mRML{} was lower at three of six wells under lowo and four of six under slot, with macro differences of 0.02 and 0.13\,p.u. Macro coverage was 0.39 and 0.48 (lowo) and 0.35 and 0.47 (slot) for the 80\% and 90\% intervals, lower than on F3 and far below the bands. No well reached nominal coverage; the highest values were 0.68 and 0.72 at F-1 B. Nothing was changed after the test wells were scored. We make no claim of improvement and no claim of calibrated uncertainty on Volve.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
@@ -223,7 +223,7 @@ slot & F-1 & 37 & B3c & 0.852 & yes & 0.270 & 0.432 \\
|
||||
\end{table}
|
||||
|
||||
\paragraph{No method had blind-well skill.}
|
||||
Table~\ref{tab:volveall} lists the five registered methods. Every macro $R^2$ was negative under both schemes ($-0.84$ to $-1.71$): each method predicted the held-out well worse than that well's own label mean, which it cannot know. The macro PCC was 0.12--0.24. After the run we added one row for scale: a constant prediction at the pooled label mean of the outer training wells, with no seismic input. Its macro RMSE was 6.03\,p.u.\ (lowo) and 6.59\,p.u.\ (slot), below every network. Networks beat it only at F-1 and F-1 B; at the other four wells every network was worse than the constant under both schemes. The reason is the between-well variation of the label. The well means of PHIF span 8.5\,p.u.\ (F-1) to 17.0\,p.u.\ (F-12), while the within-well standard deviation is 3.3--6.0\,p.u. A held-out well therefore differs from the training mean by up to 6.4\,p.u.\ before any seismic information is used, and the networks reproduced this offset rather than correcting it: the mean error of \mRML{} at each well tracked the constant's (lowo: $+3.9$ against $+4.9$\,p.u.\ at F-1, $-5.4$ against $-4.3$ at F-11 A, $-6.8$ against $-6.0$ at F-12). After removing the per-well mean error, the standard deviation of the residual of \mRML{}, averaged over wells, was 5.2\,p.u.\ (lowo) and 5.1\,p.u.\ (slot), against an average within-well label standard deviation of 4.8\,p.u., and the standard deviation of its prediction along a well was 1.1--4.1\,p.u. The predictions varied less than the label and did not follow it. Allowing a free time shift of up to $\pm 64$\,ms between prediction and label (a diagnostic that never alters a score) raised the PCC of \mRML{} to 0.40--0.82. At three (lowo) and four (slot) of the six wells, however, the chosen shift was 56--64\,ms, at or near the search limit and far outside the tie posterior ($\sigpost$ below 10\,ms; see below). With 16--37 samples, the maximum over 33 lags is an optimistic statistic, and we read this diagnostic as uninformative. The differences between tie methods, up to 0.25\,p.u.\ in macro RMSE, are therefore differences between predictions that are all dominated by an error the tie does not control. The G-D comparison had no power on these wells, and its outcome is not evidence about RML in either direction.
|
||||
Table~\ref{tab:volveall} lists the five registered methods. Every macro $R^2$ was negative under both schemes ($-0.84$ to $-1.71$). Except at F-1 B ($R^2$ 0.10--0.34 for every method under lowo, 0.05--0.07 for \mPM{} and \mRML{} under slot), each method predicted the held-out well worse than that well's own label mean, which it cannot know. The macro PCC was 0.12--0.24. After the run we added one row for scale: a constant prediction at the pooled label mean of the outer training wells, with no seismic input. Its macro RMSE was 6.03\,p.u.\ (lowo) and 6.59\,p.u.\ (slot), below every network. Networks beat it only at F-1 and F-1 B (at F-1 under slot, only \mPM{} and \mRML); at the other four wells every network was worse than the constant under both schemes. The reason is the between-well variation of the label. The well means of PHIF span 8.5\,p.u.\ (F-1) to 17.0\,p.u.\ (F-12), while the within-well standard deviation is 3.3--6.0\,p.u. A held-out well therefore differs from the training mean by up to 6.4\,p.u.\ before any seismic information is used, and the networks reproduced this offset rather than correcting it: the mean error of \mRML{} at each well tracked the constant's (lowo: $+3.9$ against $+4.9$\,p.u.\ at F-1, $-5.4$ against $-4.3$ at F-11 A, $-6.8$ against $-6.0$ at F-12). After removing the per-well mean error, the standard deviation of the residual of \mRML{}, averaged over wells, was 5.2\,p.u.\ (lowo) and 5.1\,p.u.\ (slot), against an average within-well label standard deviation of 4.8\,p.u., and the standard deviation of its prediction along a well was 1.1--4.1\,p.u. The predictions varied less than the label and did not follow it. Allowing a free time shift of up to $\pm 64$\,ms between prediction and label (a diagnostic that never alters a score) raised the PCC of \mRML{} to 0.40--0.82. At three (lowo) and four (slot) of the six wells, however, the chosen shift was 56--64\,ms, at or near the search limit and far outside the tie posterior ($\sigpost$ below 10\,ms; see below). With 16--37 samples, the maximum over 33 lags is an optimistic statistic, and we read this diagnostic as uninformative. The differences between tie methods, up to 0.26\,p.u.\ in macro RMSE, are therefore differences between predictions that are all dominated by an error the tie does not control. The G-D comparison had no power on these wells, and its outcome is not evidence about RML in either direction.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
@@ -248,7 +248,7 @@ Constant (training mean) & \textbf{6.03} & $-0.70$ & -- & -- & \textbf{6.59} & $
|
||||
\end{table}
|
||||
|
||||
\paragraph{Anchor uncertainty.}
|
||||
B3c-R, \mPM{} and \mRML{} were registered and trained again at $\sigma_a = 3.5$ and 14\,ms (Table~\ref{tab:volvesens}). The macro RMSE of \mRML{} moved by at most 0.06\,p.u.\ (lowo: 6.49, 6.50 and 6.55\,p.u.; slot: 7.13, 7.13 and 7.09\,p.u.), and coverage stayed between 0.35 and 0.52. The number of wells at which \mRML{} beat B3c-R varied between two and four of six, with no pattern across the arms. In Experiment~2 the H2a advantage depended on $\sigma_a$, and on F3 the arms changed the per-well ratios but not the outcome. On Volve they barely changed the macro error, which is consistent with the previous paragraph: when the error is set by the between-well level, the tie has little to act on.
|
||||
B3c-R, \mPM{} and \mRML{} were registered and trained again at $\sigma_a = 3.5$ and 14\,ms (Table~\ref{tab:volvesens}). The macro RMSE of \mRML{} moved by at most 0.07\,p.u.\ (lowo: 6.49, 6.50 and 6.55\,p.u.; slot: 7.13, 7.13 and 7.09\,p.u.), and coverage stayed between 0.35 and 0.52. The number of wells at which \mRML{} beat B3c-R varied between two and four of six, with no pattern across the arms. In Experiment~2 the H2a advantage depended on $\sigma_a$, and on F3 the arms changed the per-well ratios but not the outcome. On Volve they barely changed the macro error, which is consistent with the previous paragraph: when the error is set by the between-well level, the tie has little to act on.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
|
||||
@@ -70,3 +70,33 @@ Red TODO notes (`\todo`, `\todoblock`, `\figplaceholder`) were left byte-identic
|
||||
- Every red TODO, including the title note and the S1–S8/T2 placeholders.
|
||||
- Length (about 14,950 words against about 5,500): the user dropped the length pass on 29/10 (`docs/plan.md` §12 item 25).
|
||||
- Appendices A and B: checked for terminology only, no edits.
|
||||
|
||||
## Hallucination audit (04/11/2026)
|
||||
|
||||
Done with the `scientific-writing`, `literature-review`, `citation-management` and `academic-humanizer` skills. The full record is in `docs/research/paper-audit.md`; the decision log entry is `docs/plan.md` §12 item 36.
|
||||
|
||||
- Five audit passes traced every number, citation and claim to `outputs/`, the locked protocols, the code and the reference texts in `refs/`. They returned 87 findings (G1 17, G2 11, G3 14, G4 18, G5 27), of which 4 were S1:
|
||||
- the two TD models (G1-01);
|
||||
- the warp-prior fit and the fixed σ_a and σ_b (G2-01);
|
||||
- the Exp. 1 protocol tag (G3-01);
|
||||
- PHIE_DT linear in sonic at all four wells (G5-01).
|
||||
- 106 exact replacements were applied to the sections and highlights. A protected-token guard (cite, ref, label, math, numbers) against HEAD 423a333 shows only the approved changes:
|
||||
- `tab:audit` now follows `td_qc.csv`;
|
||||
- prabowo2025f3, tao2025structural and DILATE are dropped from one intro sentence;
|
||||
- about 40 small number corrections.
|
||||
- Claims were scoped to their evidence:
|
||||
- the σ_a arm covers one regime;
|
||||
- the extensions hold at R10;
|
||||
- the misspecified warp prior covers dr_L1 only;
|
||||
- T3 is exploratory and simulator-based;
|
||||
- c = 2 cells are not primary evidence for H2a but enter H2b;
|
||||
- the 500-iteration arm is a trajectory record, not retraining;
|
||||
- the BK2 cos² comparison is post hoc.
|
||||
- The academic-humanizer pass found almost no AI-style patterns left (no em-dashes, no AI vocabulary, no overclaiming verbs). It split seven long sentences, and the guard was unchanged afterwards.
|
||||
- No verdict, gate or threshold changed. 69 pages, clean build.
|
||||
- Open for the authors:
|
||||
- G1-14 (Rizzuti/BootNet DL ✓);
|
||||
- the 7 hand-downloaded PDFs, which are missing on this machine;
|
||||
- the Volve licence wording (G2-10);
|
||||
- the Rm5 "within the CI" null (G4-04);
|
||||
- the optional Kassis et al. 2026 citation.
|
||||
|
||||
Reference in New Issue
Block a user