Audit the manuscript for unsupported claims and rewrite flagged text

Five independent audits traced every number, citation and claim in the
manuscript to outputs/, the locked protocols, the code and the reference
texts (87 findings, 4 of severity S1). Fixes were verified and applied as
106 exact replacements; a protected-token guard confirms that only the
approved numbers and citations changed. A style pass split seven
overlong sentences. No verdict, gate or threshold changed.

- S1: the two time-depth models were conflated as "up to 36 ms"; the warp
  prior is fitted by MAP-II with sigma_a = 7 ms and sigma_b = 50 ms fixed
  (19 ms comes from a separate ML fit); the Exp. 1 protocol was hash-locked,
  not tagged; PHIE_DT is linear in sonic at all four F3 wells.
- tab:audit now follows outputs/td_qc.csv; unsupported intro citations
  (prabowo2025f3, tao2025structural, DILATE) dropped; claims scoped to the
  regimes actually tested; about 40 small number fixes.
- Restore docs/technical_overview.md (the lecture moves to docs/lecture.md).
- Audit record in docs/research/paper-audit.md; plan, AGENTS.md, report.html,
  paper/README.md and self_review.md synced (69 pages).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-11-04 08:25:08 +00:00
parent 423a333ae9
commit bbdb82997c
22 changed files with 1992 additions and 703 deletions

View File

@@ -3,9 +3,9 @@
A well tie is an uncertain estimate, yet learning workflows treat it as exact. Its error is an error in the time index of the label. Under an independence assumption, the error convolves the optimal predictor with its distribution and blurs the seismic band, and without time anchors the absolute timing of a network and its label alignment is not identified. An estimated tie can have the classical error structure, which blurs the learned predictor, or the Berkson structure, which sharpens it. A calibrated bank of posterior labels removes both biases in population, but its population gain over a point label is of fourth order in the tie error.
On a registration-aware synthetic benchmark calibrated to F3, the first pre-registered comparison failed because the anchor-only posterior was not informative. In the second, designed after that failure, labels at the mean of a sequential Monte Carlo tie posterior beat the best point tie by 8--22\% in seismic-band RMSE, mostly already without drift, provided that the anchor uncertainty was correctly specified. Training on the posterior bank gained further when the posterior was wide. Under the Berkson error structure that is natural for a posterior-mean tie, the gain stayed within the population limit in most cells. An exploratory test found that structure at F3-like drift, where a Gaussian bank with the first two moments of the posterior obtained most of the gain. A third experiment, designed after the field tests and run on the same test realizations, located the limits of these results. The posterior-mean advantage held at stronger drift, with a second backbone and under a misspecified warp prior. It did not hold under a frequency-dependent wavelet phase, which made the tie posterior overconfident, nor, by the registered margin, under unit-dependent rock physics. With a two-mode label error, midpoint labels reversed the sign of the learned seismic band as predicted, and a bank containing the true warp removed the reversal.
On a registration-aware synthetic benchmark calibrated to F3, the first pre-registered comparison failed; a diagnosis on development realizations showed that its likelihood-reweighted, anchor-conditioned posterior was not informative. In the second, designed after that failure, labels at the mean of a sequential Monte Carlo tie posterior beat the best point tie by 8--22\% in seismic-band RMSE, mostly already without drift, and, in the one regime where this was tested, only when the anchor uncertainty was correctly specified. Training on the posterior bank gained further when the posterior was wide. Under the Berkson error structure that is natural for a posterior-mean tie, the gain stayed within the population limit in most cells. An exploratory test found that structure at F3-like drift, where a Gaussian bank with the first two moments of the posterior obtained most of the gain in three of four cells. A third experiment, designed after the field tests and run on the same test realizations, located the limits of these results. At R10, the posterior-mean advantage held at stronger drift ($c = 1.5$), with a second backbone and under the milder of two misspecified warp priors. It did not hold under a frequency-dependent wavelet phase, which made the tie posterior overconfident, nor, by the registered margin, under unit-dependent rock physics. With a two-mode label error, midpoint labels reversed the sign of the learned seismic band as predicted, and a bank containing the true warp removed the reversal.
Whether such gains hold on field data is a question that the public datasets we examined cannot answer. A blind-well comparison of tie methods needs a reference that is independent of the seismic and accurate to about 1\,ms, enough blind wells for a test with adequate power, an anchor uncertainty estimated outside the test set, and networks with skill in the seismic band. The F3 and Volve tests met none of these conditions and failed, and Teapot Dome has independent time--depth references at no more than two of its 152 wells. We claim no improvement on field data and no calibrated uncertainty. The benchmark, the locked protocols and the detectability analysis are the means to test such claims once a dataset that meets these conditions is available.
Whether such gains hold on field data is a question that the public datasets we examined cannot answer. A blind-well comparison of tie methods needs a reference that is independent of the seismic and accurate to about 1\,ms, enough blind wells for a test with adequate power, an anchor uncertainty estimated outside the test set, and networks with skill in the seismic band. The F3 and Volve tests met none of these conditions and failed, and Teapot Dome has independent time--depth references at no more than two of the 152 wells with density logs across its target inside the 3-D survey. We claim no improvement on field data and no calibrated uncertainty. The benchmark, the locked protocols and the detectability analysis are the means to test such claims once a dataset that meets these conditions is available.
\paragraph{Data and code availability.}
The F3 Demo 2023 data are available from dGB Earth Sciences through the TerraNubis portal under a CC BY-SA 3.0 licence \citep{dgb2023f3demo}. The Volve data are available from Equinor \citep{equinor2018volve}; the licence files of the release name CC BY-NC-SA 4.0, and the data owners are Equinor, ExxonMobil, Bayerngas and the Norwegian Petroleum Directorate. The Teapot Dome data (RMOTC, U.S.\ Department of Energy) are available from the Texas Data Repository \citep{bader2017teapot}. \todo{Verify the Teapot licence on the repository page at submission (recorded as CC0 in the project notes). F3 and Volve were checked on the providers' pages on 2 November 2026.} The code, locked protocols, synthetic generator configurations and the scripts that produce every table and figure are available at \todo{repository URL and archived DOI}. The derived data from which every table and figure is computed (summaries, run-level metrics, saved test predictions and the descriptive F3 porosity volume) are archived with a manifest of SHA-256 hashes at \todo{archive DOI}, in separate archives for the F3-derived and synthetic data (CC BY-SA 3.0) and for the Volve-derived data (CC BY-NC-SA 4.0). A clean-room check recomputes the summaries, verdicts, post hoc tables and figures from the code and these archives alone, without raw seismic data. The benchmark package contains 630 tasks on the test realizations 8--15 and the development realizations 900--905, each with its inputs and its hidden true warps and labels, together with the reference results of 21 methods and a scorer that applies the locked rules; it is archived at \todo{Zenodo DOI; licence inherited from F3 (CC BY-SA 3.0), to be confirmed}.