Replicate Experiment 2 on new realizations; test sigma_a at -5 dB
Exploratory analyses declared and hashed before computing (docs/research/r6-replication.md, sha256 13b8b943...), outside every lock: - Replication on realizations 16-23: the SMC-mean gain over the best deterministic tie is 7-19% (8-22% before); the per-regime verdicts are unchanged; the SMC mode beats the best tie in 10/10 cells; the bank passes 2/3 wide cells; a Gaussian bank is within 2%. - Misspecified anchor uncertainty at -5 dB: 0/2 cells at both 3.5 and 14 ms. - Mechanism at sigma_a = 3.5 ms: the refitted drift prior becomes rougher (length scale 10-15 vs 80-90 ms); with fixed hyperparameters the posterior does not narrow. - Calibrated sign test, F-11 T2 under four references, coverage at equal training length. Paper: Sec. 6.3 and tab:sigmaa, abstract, introduction, conclusions, Sec. 3.3, 4.1, tab:lessons, limitations, App. B and C. Docs synced; the user dropped all date deadlines on 11/11/2026. No verdict, threshold or protocol changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -15,6 +15,6 @@ This study asks three questions: what such an error does to a learned predictor
|
||||
\item \textbf{Requirements for a field test.} We give the bias of scoring blind wells against a misregistered reference (Proposition~\ref{prop:reference}), derive how accurately that reference must be tied (Corollary~\ref{cor:tolerance}), and estimate how many blind wells a comparison of tie methods needs (Section~\ref{sec:exp:detect}). Two field cases, F3 and Volve, show what a test that misses these requirements can and cannot show. We also audit the public F3 well data: the porosity labels at three of the four wells are a linear function of the sonic log, and the time--depth markers are horizon-tie picks, not check shots.
|
||||
\end{enumerate}
|
||||
|
||||
The benchmark results assume a correctly specified tie model and dense anchors of known uncertainty. Under these conditions, labels at the mean of a sequential Monte Carlo (SMC) tie posterior reduced seismic-band root-mean-square error (RMSE) by 8--22\% relative to the best deterministic tie at F3-like drift. Most of this advantage was already present without drift, so it reflects a more accurate tie rather than the correction of drift. The mode of the same posterior, used as a point tie, gave most of the gain, and averaging over the posterior added at most 3\%. Against the mean of an anchor-only posterior it was 19--33\% at 10\,dB, 8--11\% at 0\,dB and 2--4\% at $-5$\,dB. Training on a bank of samples from the same posterior added a gain of 2--11\% when the posterior was wide. Better registration therefore came first, and representing the remaining uncertainty came second. Several tests failed, and each failure identifies something a tie posterior needs. A posterior that does not contract gives no gain, a wrong anchor uncertainty or wavelet phase removes the advantage, and seed ensembles do not carry tie uncertainty to new wells. Field tests on F3 and Volve showed no consistent improvement and could not have detected one, because they lack the blind wells and the independent references that a power analysis requires.
|
||||
The benchmark results assume a correctly specified tie model and dense anchors of known uncertainty. Under these conditions, labels at the mean of a sequential Monte Carlo (SMC) tie posterior reduced seismic-band root-mean-square error (RMSE) by 8--22\% relative to the best deterministic tie at F3-like drift, and by 7--19\% when the experiment was repeated on eight realizations generated afterwards. Most of this advantage was already present without drift, so it reflects a more accurate tie rather than the correction of drift. The mode of the same posterior, used as a point tie, gave most of the gain, and averaging over the posterior added at most 3\%. Against the mean of an anchor-only posterior it was 19--33\% at 10\,dB, 8--11\% at 0\,dB and 2--4\% at $-5$\,dB. Training on a bank of samples from the same posterior added a gain of 2--11\% when the posterior was wide. Better registration therefore came first, and representing the remaining uncertainty came second. Several tests failed, and each failure identifies something a tie posterior needs. A posterior that does not contract gives no gain, a wrong anchor uncertainty or wavelet phase removes the advantage, and seed ensembles do not carry tie uncertainty to new wells. Field tests on F3 and Volve showed no consistent improvement and could not have detected one, because they lack the blind wells and the independent references that a power analysis requires.
|
||||
|
||||
Section~\ref{sec:related} positions each contribution. Section~\ref{sec:data} describes the field data and the benchmark generator, Section~\ref{sec:method} the tie posteriors, the compared methods and the common loss, and Section~\ref{sec:theory} the theory (contribution~1). Section~\ref{sec:experiments} follows the remaining contributions: the controlled test of training on a tie posterior (Sections~\ref{sec:exp:p2}--\ref{sec:exp:mech}; contribution~2), the benchmark studies (Section~\ref{sec:exp:bench}; contribution~3), and detectability and the field cases (Sections~\ref{sec:exp:detect} and~\ref{sec:exp:scope}; contribution~4). Section~\ref{sec:discussion} discusses what held and what failed for each contribution and gives practical advice. Appendices give the formal results and proofs (\ref{app:proofs}), the field tests (\ref{app:field}) and the protocol record (\ref{app:record}).
|
||||
|
||||
Reference in New Issue
Block a user