Replicate Experiment 2 on new realizations; test sigma_a at -5 dB
Exploratory analyses declared and hashed before computing (docs/research/r6-replication.md, sha256 13b8b943...), outside every lock: - Replication on realizations 16-23: the SMC-mean gain over the best deterministic tie is 7-19% (8-22% before); the per-regime verdicts are unchanged; the SMC mode beats the best tie in 10/10 cells; the bank passes 2/3 wide cells; a Gaussian bank is within 2%. - Misspecified anchor uncertainty at -5 dB: 0/2 cells at both 3.5 and 14 ms. - Mechanism at sigma_a = 3.5 ms: the refitted drift prior becomes rougher (length scale 10-15 vs 80-90 ms); with fixed hyperparameters the posterior does not narrow. - Calibrated sign test, F-11 T2 under four references, coverage at equal training length. Paper: Sec. 6.3 and tab:sigmaa, abstract, introduction, conclusions, Sec. 3.3, 4.1, tab:lessons, limitations, App. B and C. Docs synced; the user dropped all date deadlines on 11/11/2026. No verdict, threshold or protocol changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -18,7 +18,7 @@ Table~\ref{tab:lessons} lists the failed tests. Three patterns recur. The traini
|
||||
Test & Outcome & Cause & Lesson \\
|
||||
\midrule
|
||||
Anchor bank, Experiment~1 & 0 of 4 cells at $c = 1$ & Posterior did not contract: warp RMSE 3.25\,ms against 3.85\,ms for the correlation tie & Check on development data that the posterior beats the best deterministic tie in warp error. SMC reached 0.56\,ms \\
|
||||
Anchor uncertainty halved or doubled & 0 of 2 cells in each arm (one setting) & Posterior miscalibrated both ways: coverage 0.62 and 0.52 against 0.89 & Estimate $\sigma_a$ from independent time--depth data outside the test set \\
|
||||
Anchor uncertainty halved or doubled & 0 of 2 cells in each arm, at 10\,dB and (exploratory) at $-5$\,dB & Posterior miscalibrated both ways: coverage 0.62 and 0.52 against 0.89 at 10\,dB; over-trusted anchors made the fitted drift prior rougher & Estimate $\sigma_a$ from independent time--depth data outside the test set \\
|
||||
Frequency-dependent wavelet phase & Ratio 1.023 and 1.042 & Constant-phase fit collapsed onto a wrong warp: coverage 0.17 and 0.10 & Compare the SMC mean warp with a correlation tie built with the statistical wavelet (untested), which degraded by at most 4\% \\
|
||||
Unit-dependent rock physics & Ratio 0.940 and 0.934; missed 0.90 & Every method worsened (Oracle up to 1.84 times); registration still worked and the squared-error gain was largely kept & The tie posterior stays usable; judge gains in absolute error as well as by ratio \\
|
||||
Advantage over the anchor mean at $-5$\,dB & 0 of 2 cells; ratios 0.98 and 0.97 & Seismic likelihood adds little to the anchors at low SNR$^\ast$ & Expect the SMC posterior to help mainly where the seismic constrains the tie \\
|
||||
@@ -47,7 +47,7 @@ These recommendations hold within this benchmark, where the data follow the regi
|
||||
Proposition~\ref{prop:reference} and the detectability analysis turn the field failures into four requirements, derived under the benchmark simulator.
|
||||
\begin{enumerate}
|
||||
\item \emph{A reference independent of the seismic and, in our simulations, accurate to the order of 1\,ms.} To leading order, the measured advantage has the sign of the true one only if the reference error is below $1/\sqrt2$ times the tie error being detected (Corollary~\ref{cor:tolerance}), and power is lost well before that point. Check shots or a vertical seismic profile can in principle meet this requirement once their datum and statics are reconciled with the seismic. The one comparison we have is at Volve well F-11 T2, where the operator's picks lay within $-6.1$ to $+2.3$\,ms of the VSP and the marker-calibrated sonic within $-2.4$ to $-0.8$\,ms (Appendix~\ref{app:field}). A reference tied by synthetic--seismic matching on the same seismic cannot, because its error is not independent of the predictions.
|
||||
\item \emph{A number of blind wells set by a power analysis, with a test as the pass rule.} With four blind wells, as on F3, a one-sided sign test at $\alpha = 0.05$ cannot reject at all, because its smallest attainable $p$-value is $1/16$. With an exact reference, a sign test reached a power of 0.8 with 5--18 blind wells in five of the six cells. At 1\,ms it needed 11--30 wells in four cells, and at 3\,ms or more no cell reached that power with 40 wells. Section~\ref{sec:exp:detect} works through one case.
|
||||
\item \emph{A number of blind wells set by a power analysis, with a test as the pass rule.} With four blind wells, as on F3, a one-sided sign test at $\alpha = 0.05$ cannot reject at all, because its smallest attainable $p$-value is $1/16$. With an exact reference, a nominal sign test reached a power of 0.8 with 5--18 blind wells in five of the six cells; with its null calibrated for blind wells that share training data, four cells reached it with 5--18 wells. At 1\,ms the calibrated test needed 16 and 25 wells in two cells, and at 1.5\,ms or more no cell reached that power with 40 wells. The test must account for that sharing, because the nominal sign test rejects a true null far more often than its level when the outcomes of blind wells are correlated. Section~\ref{sec:exp:detect} works through one case.
|
||||
\item \emph{An anchor uncertainty estimated outside the test set} (item 2 above).
|
||||
\item \emph{Networks with skill in the seismic band at blind wells,} shown before registration is compared.
|
||||
\end{enumerate}
|
||||
@@ -57,10 +57,10 @@ The two field cases meet none of the four. Neither F3 nor Volve is evidence agai
|
||||
\begin{itemize}
|
||||
\item \textbf{One simulator.} In the nominal cells the data follow the rock physics and the warp-prior family that the registration assumes, with a registration prior on the bulk offset wider than the truth, so the gains there are not estimates of the gains to expect on field data. Every confirmatory result comes from one generator family with statistics estimated on F3. Lateral heterogeneity, multiples, anisotropy and non-stationary noise were not simulated, and the misspecification levels are not calibrated to any field.
|
||||
\item \textbf{Band of the benchmark.} In the benchmark, 72\% of the band power of the synthetic labels and 73\% of that of the Oracle predictions at 10\,dB lies below 25\,Hz, so the low-frequency concentration of the predictions is already present in the labels. The F3 $\mathrm{PHIE}_{\mathrm{DT}}$ labels are richer in high frequencies, with 54\% below 25\,Hz (46--68\% across the four wells), and the F3 seismic peaks near 60\,Hz (Table~\ref{tab:bandspectra}; post hoc and descriptive). The measured sensitivities to timing error may therefore understate what a label with more high-frequency content would suffer. We did not test this.
|
||||
\item \textbf{Dependence between tests.} Experiment~2 was designed after Experiment~1 had failed. Experiment~3 reuses its test realizations and SMC particles and was designed after the field tests and post hoc analyses. F3 also supplied the statistics of the generator, and the Volve test was designed after the F3 test had failed.
|
||||
\item \textbf{Dependence between tests.} Experiment~2 was designed after Experiment~1 had failed. Its main comparisons were repeated on eight realizations generated afterwards (Section~\ref{sec:exp:p2r}), but under reading rules written after its results were known. Experiment~3 reuses its test realizations and SMC particles, was designed after the field tests and post hoc analyses, and was not replicated, because its runner is locked to those realizations. F3 also supplied the statistics of the generator, and the Volve test was designed after the F3 test had failed.
|
||||
\item \textbf{Tempering.} Every hash-locked bank used $\lambda = 1/\tau_c$, a heuristic fixed in advance, where RML is not near the limit analysed in Section~\ref{sec:theory:post}. The $\lambda \to 0$ objective and MSE on the bank-mean label were trained only in an exploratory arm declared after all verdicts (Appendix~\ref{app:record}). That arm cannot confirm Proposition~\ref{prop:bank}, because the SMC bank is finite and has not been shown to be calibrated.
|
||||
\item \textbf{Strong drift.} At $c = 2$ the mean warp of the SMC posterior was unstable between runs and the posterior was often multimodal. These cells are not primary evidence for the posterior-mean claim.
|
||||
\item \textbf{Untested stresses.} The anchor-uncertainty stress was tested in one setting only (10\,dB, $c = 1$, where the posterior is narrow), and its effect at $-5$\,dB, where the posterior is wide and F3-like, is unknown. Experiment~3 did not vary the anchor uncertainty, varied the bulk-offset prior only together with the other drift hyperparameters, and tested cycle skipping only in an idealized two-mode form. At low SNR the SMC stability criterion failed in one of four development cells at $c = 1$, mainly through the phase estimate.
|
||||
\item \textbf{Untested stresses.} The anchor-uncertainty stress was tested at $c = 1$ only, at 10\,dB (hash-locked) and at $-5$\,dB (exploratory), and only with factor-of-two errors; the benchmark package carries two such settings at 10\,dB, but no hash-locked benchmark test varied the anchor uncertainty. Experiment~3 varied the bulk-offset prior only together with the other drift hyperparameters, and tested cycle skipping only in an idealized two-mode form. At low SNR the SMC stability criterion failed in one of four development cells at $c = 1$, mainly through the phase estimate. Seismic noise correlated between traces, TCN budgets below 125 iterations and a Gaussian bank on the misspecification axes of the benchmark were not tested.
|
||||
\item \textbf{Uncertainty quantification.} Seed ensembles under-covered for every method ($\xi$ of 0.19--0.66 at 10\,dB, $c = 1$, $N = 16$; on F3 the macro 80\% coverage of every hash-locked probabilistic method was 0.38--0.52, on Volve 0.29--0.39). Because training length and label source are confounded, the population statements of Proposition~\ref{prop:coverage} for the point label and the calibrated bank remain untested.
|
||||
\item \textbf{Backbone.} Apart from two F3 ablations, the only second backbone is the TCN, in three settings; it was weaker and selected the smallest budget, so this is a check of robustness. Assumption (A3) holds only approximately for either backbone.
|
||||
\item \textbf{Detectability.} The analysis rescored predictions with the skill of Experiment~2 against references whose errors are smooth and independent of the predictions. A reference tied on the same seismic adds a covariance with the predictions that we did not model.
|
||||
|
||||
Reference in New Issue
Block a user