Replicate Experiment 2 on new realizations; test sigma_a at -5 dB
Exploratory analyses declared and hashed before computing (docs/research/r6-replication.md, sha256 13b8b943...), outside every lock: - Replication on realizations 16-23: the SMC-mean gain over the best deterministic tie is 7-19% (8-22% before); the per-regime verdicts are unchanged; the SMC mode beats the best tie in 10/10 cells; the bank passes 2/3 wide cells; a Gaussian bank is within 2%. - Misspecified anchor uncertainty at -5 dB: 0/2 cells at both 3.5 and 14 ms. - Mechanism at sigma_a = 3.5 ms: the refitted drift prior becomes rougher (length scale 10-15 vs 80-90 ms); with fixed hyperparameters the posterior does not narrow. - Calibrated sign test, F-11 T2 under four references, coverage at equal training length. Paper: Sec. 6.3 and tab:sigmaa, abstract, introduction, conclusions, Sec. 3.3, 4.1, tab:lessons, limitations, App. B and C. Docs synced; the user dropped all date deadlines on 11/11/2026. No verdict, threshold or protocol changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -164,6 +164,8 @@ The six wells are held out under two schemes. Under \emph{lowo}, each well is th
|
||||
\paragraph{Neither condition held.}
|
||||
Under lowo, inner validation chose the calibrated sonic at every well, and the \mRML{} had lower RMSE at two wells (F-1 B by 1.1\% and F-11 T2 by 1.5\%) and was 0.4--4.6\% worse at the other four (Table~\ref{tab:volvegd}). Its macro RMSE was 6.50\,p.u.\ against 6.36\,p.u.\ for the calibrated sonic. Under slot, inner validation chose the correlation tie in the F-1 slot and the calibrated sonic in the others, and the \mRML{} improved at three wells. The two large ratios in that scheme, 0.85 at F-1 and 0.90 at F-1 B, are against the correlation tie, which had the lowest inner-validation MSE in that fold but was worse than the calibrated sonic at both test wells (8.04 against 7.27\,p.u.\ and 5.35 against 5.17\,p.u.); against the calibrated sonic, the \mRML{} is 5.7\% better at F-1 and 7.2\% better at F-1 B. Its macro RMSE under slot was 7.13\,p.u.\ against 7.32\,p.u.\ for the selected ties. Against the \mPM{}, the \mRML{} was lower at three of six wells under lowo and four of six under slot, with macro differences of 0.02 and 0.13\,p.u. Macro coverage was 0.39 and 0.48 (lowo) and 0.35 and 0.47 (slot) for the 80\% and 90\% intervals, and no well reached nominal coverage; the highest values were 0.68 and 0.72 at F-1 B.
|
||||
|
||||
F-11 T2 is the only well at which the reference can be compared with an independent time--depth measurement. Scored at $\sigma_a = 7$\,ms against each of the four references of the protocol (the label placed by the marker-calibrated sonic, by linear interpolation between the picks without the sonic, and by the two VSP time--depth tables of the well, NIVSP and OPTIMIZED), the ensemble RMSE of each method moved by 0.31--0.51\,p.u.\ across references, while the spread between the five methods under one reference was 0.12--0.29\,p.u. The ranking changed with the reference: under lowo the correlation tie was best against both VSP tables and the calibrated sonic, and the \mPM{} against the pick interpolation; under slot the \mRML{} was best against the pick interpolation and third against both VSP tables. The references score 20--24 labelled samples, so part of the change comes from the samples themselves. This comparison is post hoc (declared before it was computed, after the results were known) and covers one well; it shows that at Volve the choice of reference is not a detail of the scoring.
|
||||
|
||||
\begin{table}[t]
|
||||
\centering
|
||||
\caption{Volve pass rule (label PHIF, marker-calibrated vertical-sonic reference, labelled samples in 2400--2900\,ms, $\sigma_a = 7$\,ms, combined ensembles). Competitor: the deterministic tie chosen by inner validation. Ratio: RMSE of \mRML{} divided by that of the competitor. $n$: labelled 4\,ms samples. Coverage: fraction of those samples inside the central interval of \mRML. F-12 is alone in its slot, so its two rows are identical.}
|
||||
|
||||
Reference in New Issue
Block a user