Regenerate figures with descriptive names; add band-content table

Regenerate p2_phase, p2r_grid, p2r_h2b, bench_s1 and bench_s8 from the
existing summaries so they use the paper's descriptive names, and remove
the \figcodes notes and macro. Display fixes only: mathtext for the
-5 dB label and a shorter anchor-mean cell label.

Add a post hoc, descriptive table of the band content of the F3 labels,
the synthetic labels and the Oracle predictions (scripts/40_band_spectra.py,
Table tab:bandspectra in App. C) and rewrite the "Band of the benchmark"
limitation. No number, verdict, threshold, locked protocol or abstract
changed. Clean-room check rerun: 12/12 stages pass, nothing differs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-11-09 08:56:10 +00:00
parent 8d5befb412
commit df5cb937e8
18 changed files with 189 additions and 24 deletions

View File

@@ -56,7 +56,7 @@ The two field cases meet none of the four. Neither F3 nor Volve is evidence agai
\paragraph{Limitations.}
\begin{itemize}
\item \textbf{One simulator.} In the nominal cells the data follow the rock physics and the warp-prior family that the registration assumes, with a registration prior on the bulk offset wider than the truth, so the gains there are not estimates of the gains to expect on field data. Every confirmatory result comes from one generator family with statistics estimated on F3. Lateral heterogeneity, multiples, anisotropy and non-stationary noise were not simulated, and the misspecification levels are not calibrated to any field.
\item \textbf{Band of the benchmark.} The learned predictors have coherent power mostly below about 25\,Hz, whereas the F3 seismic peaks near 60\,Hz. The measured sensitivities to timing error may therefore understate what a label with more high-frequency content would suffer.
\item \textbf{Band of the benchmark.} In the benchmark, 72\% of the band power of the synthetic labels and 73\% of that of the Oracle predictions at 10\,dB lies below 25\,Hz, so the low-frequency concentration of the predictions is already present in the labels. The F3 $\mathrm{PHIE}_{\mathrm{DT}}$ labels are richer in high frequencies, with 54\% below 25\,Hz (46--68\% across the four wells), and the F3 seismic peaks near 60\,Hz (Table~\ref{tab:bandspectra}; post hoc and descriptive). The measured sensitivities to timing error may therefore understate what a label with more high-frequency content would suffer. We did not test this.
\item \textbf{Dependence between tests.} Experiment~2 was designed after Experiment~1 had failed. Experiment~3 reuses its test realizations and SMC particles and was designed after the field tests and post hoc analyses. F3 also supplied the statistics of the generator, and the Volve test was designed after the F3 test had failed.
\item \textbf{The $\lambda \to 0$ objective was not trained.} Every bank used $\lambda = 1/\tau_c$, where RML is not near the limit analysed in Section~\ref{sec:theory:post}, and neither MSE on the bank-mean label nor the $\lambda \to 0$ loss was run. The tempering is a heuristic fixed in advance.
\item \textbf{Strong drift.} At $c = 2$ the mean warp of the SMC posterior was unstable between runs and the posterior was often multimodal. These cells are not primary evidence for the posterior-mean claim.