Address simulated GP referee reports: E1-E6 and A1-A9 (exploratory), theory scope, per-well field and anchor-error tables, scorer v1.1, paper_gp and response letter

Experiments declared and hashed before computing (docs/research/gp-review-*.md). The SMC-mean gain holds against a practitioner tie, all budgets and a same-target point tie, but is lost at anchor errors of 2 ms or less and reverses with per-well bulk error. No locked protocol, verdict or threshold changed.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-11-17 11:20:54 +00:00
parent 883dccfe21
commit eff975cc96
91 changed files with 8595 additions and 14266 deletions

View File

@@ -1,19 +1,19 @@
\section{Conclusions}
\label{sec:conclusion}
A well tie is an uncertain estimate, yet learning workflows treat it as exact. Treating its error as an error in the time index of the label predicts two opposite effects: timing errors independent of the data blur the optimal predictor, whereas the error of a posterior-mean tie is predicted to sharpen it in a linear-Gaussian model; on the benchmark no sharpening was detected. Without anchors, absolute timing is not identified. For Gaussian errors, a calibrated bank of posterior labels has a population gain of only fourth order in the tie error, so finite-sample effects can dominate.
A well tie is an uncertain estimate, yet learning workflows treat it as exact. Treating its error as an error in the time index of the label predicts two opposite effects. Timing errors independent of the data blur the optimal predictor, whereas in a linear-Gaussian model the error of a posterior-mean tie is predicted to sharpen it. On the benchmark, where this could be tested, the trained network was blurred, not sharpened. Without anchors, absolute timing is not identified. For Gaussian errors, a calibrated bank of posterior labels has a population gain of only fourth order in the tie error, so finite-sample effects can dominate.
Where the true timing was known, the outcome depended first on the tie posterior. A posterior that did not contract gave no gain, and one that did gave labels with 8--22\% lower seismic-band RMSE than the best deterministic tie, and 7--19\% lower on eight realizations generated afterwards. That gain reflects a more accurate tie model (against the mean of an anchor-only posterior it was 2--33\%, shrinking as noise grew): the mode of the same posterior, used as a point tie, gave most of the gain, and averaging over the posterior added at most 3\%. A bank of posterior samples added a smaller gain when the posterior was wide, so registration comes first and representing its remaining uncertainty second.
Where the true timing was known, the outcome depended first on the tie posterior. A posterior that did not contract gave no gain, and one that did gave labels with 8--22\% lower seismic-band RMSE than the best deterministic tie, and 7--19\% lower on eight realizations generated afterwards. That gain reflects a more accurate tie model: the best saved particle of the same posterior, used as a point tie, gave most of the gain, and averaging over the posterior added at most 3\%. Against the mean of an anchor-only posterior the gain was 2--33\%, shrinking as noise grew. A bank of posterior samples added a smaller gain when the posterior was wide, so registration comes first and representing its remaining uncertainty second.
The benchmark located where these results stop. The advantage required a correct anchor uncertainty, at 10\,dB and at $-5$\,dB, and a wavelet phase within the tie model. It held at stronger drift, with a second backbone and under a scaled warp prior that tested mainly the benign direction, and a two-mode label error reversed the sign of the learned seismic band as predicted. Released with reference results, a scorer and the locked rules, the benchmark lets other tie methods be compared where the truth is known.
The benchmark located where these results stop. The advantage was lost when the anchor uncertainty was misstated by a factor of two in either direction, at 10\,dB and at $-5$\,dB, when the true anchor error was 2\,ms or less or had a per-well bulk component, and when the wavelet phase lay outside the tie model. It held at stronger drift, with a second backbone and under a scaled warp prior that tested mainly the benign direction. A two-mode label error reversed the sign of the learned seismic band, as predicted. Released with reference results, a scorer and the locked rules, the benchmark lets other tie methods be compared where the truth is known.
Whether such gains hold on field data remains open. F3 and Volve showed no consistent improvement, and Teapot Dome has independent time--depth references at no more than two of the 152 wells with density logs across its target inside the 3-D survey. A field comparison of tie methods needs, for effects of the size found in the benchmark, a reference independent of the seismic and accurate to the order of 1\,ms in our simulations, enough blind wells for a test with adequate power, an anchor uncertainty estimated outside the test set, and networks with skill in the seismic band. The detectability analysis and the locked protocols allow these gains to be tested once a dataset that meets these conditions is available.
Whether such gains hold on field data remains open. F3 and Volve showed no consistent improvement, and Teapot Dome has independent time--depth references at no more than two of the 152 wells with density logs across its target inside the 3-D survey. For effects of the size found in the benchmark, a field comparison of tie methods needs a reference independent of the seismic and accurate to the order of 1\,ms in our simulations, enough blind wells for a test with adequate power, an anchor uncertainty estimated outside the test set, and networks with skill in the seismic band. The detectability analysis and the locked protocols allow these gains to be tested once a dataset that meets these conditions is available.
\paragraph{Data and code availability.}
The F3 Demo 2023 data are available from dGB Earth Sciences through the TerraNubis portal under a CC BY-SA 3.0 license \citep{dgb2023f3demo}. The Volve data are available from Equinor \citep{equinor2018volve}; the license files of the release name CC BY-NC-SA 4.0, and the data owners are Equinor, ExxonMobil, Bayerngas and the Norwegian Petroleum Directorate. The Teapot Dome data (RMOTC, U.S.\ Department of Energy) are available from the Texas Data Repository \citep{bader2017teapot}. \todo{Verify the Teapot license on the repository page at submission (recorded as CC0 in the project notes). F3 and Volve were checked on the providers' pages on 2 November 2026.} The code, locked protocols, synthetic generator configurations and the scripts that produce every table and figure are available at \todo{repository URL and archived DOI}. The derived data from which every table and figure is computed (summaries, run-level metrics, saved test predictions and the descriptive F3 porosity volume) are archived with a manifest of SHA-256 hashes at \todo{archive DOI}, in separate archives for the F3-derived and synthetic data (CC BY-SA 3.0) and for the Volve-derived data (CC BY-NC-SA 4.0). A clean-room check recomputes the summaries, verdicts, post hoc tables and figures from the code and these archives alone, without raw seismic data. The benchmark package contains 658 tasks on the test realizations 8--15 and the development realizations 900--905, each with its inputs and the true warps and labels used for scoring, together with the reference results of 21 methods and a scorer that applies the locked rules. The truth is included, so the package supports controlled comparisons rather than blind evaluation; it is archived at \todo{Zenodo DOI; license inherited from F3 (CC BY-SA 3.0), to be confirmed}.
\paragraph{Computer code availability.}
\todo{Required by Computers \& Geosciences. Fields in the journal's template (unverified against the current guide): name of the code; developers and contact (e-mail, phone); year first available; hardware requirements (development on an NVIDIA RTX 3060 12\,GB and an H200); software required (Python 3.12, PyTorch; give the versions of the environment locks); program language; program size; license; repository link.}
\todo{Needed only for the Computers \& Geosciences fallback; the Geophysical Prospecting version (\texttt{paper\_gp/}) states code and data access in its Data Availability Statement. Fields in the journal's template (unverified against the current guide): name of the code; developers and contact (e-mail, phone); year first available; hardware requirements (development on an NVIDIA RTX 3060 12\,GB and an H200); software required (Python 3.12, PyTorch; give the versions of the environment locks); program language; program size; license; repository link.}
\paragraph{CRediT authorship contribution statement.}
\todo{Author contributions.}
@@ -22,7 +22,7 @@ The F3 Demo 2023 data are available from dGB Earth Sciences through the TerraNub
\todo{Competing interests.}
\paragraph{Declaration of generative AI and AI-assisted technologies.}
\todo{Elsevier requires authors to disclose the use of generative AI in preparing the manuscript. The authors must write this statement.}
\todo{The authors must write this statement. A draft in the form EAGE asks for (tool named, parts of the text it helped with) is in the Acknowledgments of \texttt{paper\_gp/main.tex}.}
\paragraph{Acknowledgements.}
We thank dGB Earth Sciences for making the F3 data available as an OpendTect project via their TerraNubis portal (terranubis.com), and Equinor and the former Volve license partners (ExxonMobil and Bayerngas) and the Norwegian Petroleum Directorate for releasing the Volve data. \todo{Other acknowledgements and funding.}