Add P6 benchmark code, locked protocol_bench, T2 study and lock inputs

- ml_porosity/benchmark/ runner, scripts 32-35, scripts/run_bench.sh;
  misspec= option in synth_d2 (default path reproduces P2r bit for bit).
- configs/protocol_bench.{yaml,sha256,lock.json} locked 29/10 14:39 UTC
  (sha256 aa763f0a...), configs/d2_synth_bench.yaml.
- The eight protocol_bench inputs force-added from outputs/ (warp prior,
  wavelets, horizon cache, budgets) so load_protocol() and summarize work
  after a fresh clone. The 102 P2r reference artifacts (1.4 GB of particle
  npz) are not in git; they are only checked by posterior/train stages.
- T2 mechanism declaration and results; operations/p6_supervisor.py.
- Docs, report and paper edits of 29/10.

Main S1 runs are still training at this commit; results follow.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-30 01:06:59 +00:00
parent 0cfe202a8b
commit f3c30517fa
51 changed files with 6529 additions and 58 deletions

View File

@@ -1,10 +1,13 @@
\section{Theory}
\label{sec:theory}
This section asks what a registration error in the training labels does to a learned predictor and to its evaluation. Section~\ref{sec:theory:blur} shows that independent timing errors blur the optimal predictor, and Section~\ref{sec:theory:ident} that without anchors absolute timing is not identified. Section~\ref{sec:theory:post} distinguishes the two error structures of an estimated tie and bounds what a bank of posterior labels can gain. Sections~\ref{sec:theory:cov} and~\ref{sec:theory:ref} relate the error to the coverage of predictive intervals and to the bias of scoring against a misregistered reference. Proofs are in Appendix~\ref{app:proofs}.
\paragraph{Notation.}
$t$ is seismic two-way time, $X$ the seismic input around a well, and $y(t)$ the label under correct registration. $\delta(t)$ is the registration error, and the observed label is $\tilde y(t) = y(t + \delta(t))$. The oracle predictor is $m(t) = \E[y(t)\mid X]$, the MSE-optimal predictor under correct labels. The Fourier transform is $\hat g(f) = \int g(t)\,e^{-i2\pi f t}\dd t$, and $T_\beta h(t) = h(t-\beta)$ is a time shift. $S_a$ is the power spectrum of $a$. The seismic band is $|f| \ge f_c$ with $f_c = 6$\,Hz, and $B$ is the corresponding high-pass operator, with $a_b = Ba$. In the experiments $B$ is a zero-phase fourth-order Butterworth filter. Its response is real and non-negative, so every result below holds with $S$ replaced by $|H_B|^2 S$. Spectral statements assume second-order stationarity in $t$, which is a working assumption for well logs.
\subsection{Misregistered labels blur the optimal predictor}
\label{sec:theory:blur}
\begin{proposition}[Blur]
\label{prop:blur}
@@ -74,6 +77,7 @@ $\sigma$ (ms) & $r(\sigma)$ & 95\% CI & frequencies & band RMSE & band PCC & ban
\end{figure}
\subsection{Without anchors, absolute timing is not identified}
\label{sec:theory:ident}
Consider $N$ training wells with seismic $X_w$, depth logs $\phi_w$ and warps $u_w = (b_w, g_w)$ (Section~\ref{sec:method:prior}). Let $y^{u}(t) = (\aaf\phi)(z_u(t))$ be the label under warp $u$, where $z_u$ inverts $t_u$ and $\aaf$ is an anti-alias filter. Let $e_b$ be the direction that adds the same $\beta$ to every $b_w$. The joint MAP objective over network parameters $\theta$ and warps $\mathbf{u}$ is
\begin{equation}