Commit Graph

3 Commits

Author SHA1 Message Date
df5cb937e8 Regenerate figures with descriptive names; add band-content table
Regenerate p2_phase, p2r_grid, p2r_h2b, bench_s1 and bench_s8 from the
existing summaries so they use the paper's descriptive names, and remove
the \figcodes notes and macro. Display fixes only: mathtext for the
-5 dB label and a shorter anchor-mean cell label.

Add a post hoc, descriptive table of the band content of the F3 labels,
the synthetic labels and the Oracle predictions (scripts/40_band_spectra.py,
Table tab:bandspectra in App. C) and rewrite the "Band of the benchmark"
limitation. No number, verdict, threshold, locked protocol or abstract
changed. Clean-room check rerun: 12/12 stages pass, nothing differs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-09 08:56:10 +00:00
0cfe202a8b Complete P4 Volve; pivot the manuscript to theory + benchmark
P4 (Volve field case). Add the deviated-well and Volve well builders
(ml_porosity/data/deviated.py, volve_wells.py), the ml_porosity/volve/
pipeline, scripts 23-25, the run_p4 drivers and tests. The protocol
configs/protocol_volve.yaml was locked at 2026-10-29T01:17:42Z before the
run (.sha256, .lock.json) and is committed here after the run. Gate G-D
failed: M2-Sa beats the selected B3 at 2/6 wells (lowo) and 3/6 (slot),
coverage90 is about 0.47, and no method has blind-well skill (R2 < 0).
A post hoc constant at the training-well mean beats every network, so
G-D had no power. The dropped P4x exploratory run is kept as a record
only (exploratory/, docs/research/p4-exploratory.md).

Applicability and Teapot Dome (exploratory, pre-declared). Scripts 26-29
and docs/research/applicability-*.md: F3 and Volve fail C1 and pass C2;
T3 power needs 5-18 blind wells with an exact reference; Teapot T0 and
pilot P-a failed, so Teapot is stopped. Raw Teapot data stay gitignored.

Manuscript (Pivot 1, level A). Reframe paper/ as a theory and synthetic
benchmark paper: Propositions 3-6, Corollaries 3-4, T4 coverage
(script 30) and the post hoc H2b bound check (script 31), with F3/Volve
moved to Appendix B. Correct two earlier claims: the Berkson and
classical bounds differ by 1.5-4.6x at the f^4-weighted band, and the
bank gain exceeds the registered classical bound (7/8 wide cells at
N = 16) but only 3/8 under the post hoc Berkson bound.

Docs. Sync plan, AGENTS.md, README, report.html, theory and technical
overview. The length pass for the venue is dropped by the user
(plan section 12 item 25); the length risk stays recorded as R9.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-29 12:18:22 +00:00
4a5d0b26e6 Add manuscript draft with F3 results; close P3
- paper/: LaTeX draft. Section 6.4 reports the F3 nested leave-one-well-out
  test (gate G-C failed: 1/4 wells improved, macro coverage 0.52/0.61) with
  all-method, sensitivity and ablation tables, posterior width, LOAO and the
  descriptive volume. Discussion, abstract, introduction and conclusion carry
  the F3 outcome; Volve parts remain marked as todo.
- Correct the pre-registration wording for F3: the protocol hash lock
  preceded the run, but the protocol was committed and tagged only after it.
- scripts/22_paper_figures.py: paper figures, including the F3 inline
  section (f3_volume).
- docs/plan.md §12 item 17: close P3 without a rerun, record the lock
  timeline, the post hoc descriptive analyses and the axis label issue in
  the locked plot_sections.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-28 07:13:20 +00:00