# Response to the simulated referee reports GP-A, GP-B and GP-C (17/11/2026) Written for: the authors, as the basis of a response letter; the referees are simulated (two Fable subagents and one external model), not journal referees. Numbers come from `docs/research/gp-review-results.md` and `outputs/gp_review/`. All new analyses were declared and hashed before computing (`gp-review-experiments.md`, `gp-review-analyses.md`) and sit outside every locked protocol. ## 1. Self-contained article The GP article now carries the nominal and replication intervals, point-tie comparisons, anchor sensitivity, misspecification, per-well results and verdicts. It defines the point-tie and alignment competitors and explains the F3 timing audit and sonic-derived label. Theory statements and proofs are in Appendix A. ## 2. Headline against the best point tie of any kind The 8–22% gain is stated against the best deterministic tie; the best saved particle (same SMC model, a point tie) beats it in all cells and posterior averaging adds at most 3%. New: (E2) a practitioner-grade tie tuned on development realizations has 1.05–1.22 times the correlation tie error at 10 dB and is the lowest-error deterministic tie in some noisier cells. With it added, the SMC mean meets the rule in five of six cells in each realization set; (E4) a point tie that optimizes the SMC target itself beats the best deterministic tie in 12 of 12 cells (0.79–0.91) and the interval against the SMC mean includes one in nine cells; (E6) the gain holds at 125, 250 and 500 iterations (6 of 6 cells each). The abstract says so. ## 3. The anchor-noise model and the true sigma_a (E1, realizations 24–31) This changes the claim. With independent anchor noise of 4 ms, stated correctly, the SMC mean is 0.930 and 0.915 times the best tie; at 2 ms 0.979 and 0.969; at 1 ms 0.987 and 0.989 (both intervals include one); with a per-well bulk error of 5 ms added to 2 ms noise it is 1.05–1.30 times the best tie for every stated sigma_a, with an overconfident posterior (coverage 0.48–0.63). The largest gains in this stress study occur with independent errors of 4–7 ms. At 2 ms and 16 training wells the ratio remains below unity, 0.969 [0.961, 0.979]. The abstract, Experiment 2, Limitations and Conclusions say this; "the gain requires a correct sigma_a" became "is sensitive to a twofold misstatement in either direction (at 10 and −5 dB)". ## 4. Theory versus experiments (GP-C) (a) The label at the posterior-mean warp and the posterior mean of the labels are now kept apart in Methods and Theory; Experiment E5 trains on the latter with the Gaussian likelihood: it improves on the SMC mean by 0.8–1.7% in six of eight wide cells (3.1% and 11.9% in two), and the bank improves on it in seven of eight, so the bank gain is not only that correction. (b) The fourth-order statement is restricted to Gaussian, data-independent shifts, a calibrated bank and lambda → 0; rho* is called a population limit. (c) Figure 4b: recomputing from pooled errors changes no point by more than 0.011 and none crosses the diagonal (A8). (d) The 67–72 Hz band of the limits lies outside the 6.8–22.5 Hz in which blur was verified; stated. (e) The Gaussian-bank count was wrong ("within 2.5% in three of four"): all four ratios are 0.0–2.1% above the bank, the interval of the difference includes zero in three (A9). Corrected. ## 5. Misspecification Pass counts are replaced by the misspecification table (ratio, interval, warp error, coverage per preset); the wavelet phase is named the worst case. A5: truth-free posterior checks do not separate failing from passing presets. ## 6. Blind-well requirements The text distinguishes the target for a fixed pair of predictors from power computed over pooled synthetic realizations. The assumptions of the sigma/sqrt(2) condition, the unobservable intraclass correlation and the 18 degrees phase equivalent of 1 ms at 50 Hz are stated; the numbers are conditions for a powered test in this benchmark, not a standard. Wilcoxon and t tests need 25–50% fewer wells (A6). ## 7. Field cases A per-well table for F3 and Volve; the lack of power is tied to the failed blind-well skill condition. ## 8. Smaller points "Scaled MAD" (6.9 ms; raw MAD 4.65 ms, SD 16.5 ms over 18 pairs); Balakrishnan citation; Di & Abubakar 2023 cited; "<7%" versus Table S7 reconciled; "hash-locked" wording; AI statement no longer claims that every citation was checked. ## 9. Not done A3 met its declared sufficiency rule for the proposed E3 arm (104 of 140 powered combinations within ±10%). A correlated-anchor inference model and a separate replication of Experiment 3 remain outside these results. Scorer v1.1 is documented. The GP revision results are archived with six clean-room stages in [repro/README.md](../../../repro/README.md). The new independent [GP-D report](GP-D_round1.md) recommends major revision.