# Referee 1 report (round 1) — Computers & Geosciences Manuscript: *Label registration error in sparse-well seismic property learning: theory, a registration-aware benchmark, and the limits of field validation* Referee profile: applied geophysicist, seismic reservoir characterization / QI (well ties, inversion, seismic-to-property prediction). --- ## 1. Summary and claimed contributions The paper treats the well-tie error that places well-log labels on the seismic time axis as an error in the *time index* of the training label, rather than in its value, and asks what this does to a learned seismic-to-porosity predictor. Theoretically (Sec. 4, App. A) it shows that an independent ("classical") timing error convolves the MSE-optimal predictor with the error distribution, so the seismic band is attenuated by the characteristic function of the error; that without time anchors a network and its label alignment can drift together (absolute timing unidentified); that the error of a posterior-mean tie has Berkson rather than classical structure and *sharpens* instead of blurring; that a calibrated bank of posterior labels recovers the oracle population optimum but with a population gain only of fourth order in the tie error; and that scoring against a misregistered reference biases blind-well comparisons unless the reference error is below sigma/sqrt(2) of the tie error. Methodologically (Sec. 5) it defines RML_lambda, a tempered log-likelihood over a bank of labels, and shows that point-tie NLL, hard/soft shift losses and soft-DTW are special cases. Empirically it builds a synthetic benchmark from F3 geometry, rock physics, wavelet and a warp prior fitted to F3 markers, runs three hash-locked experiments (the first failed; the second, designed after the failure, showed that labels at the SMC posterior-mean warp beat the best point tie by 8–22% in band RMSE, and that the bank helps a further 2–11% when the posterior is wide; the third extends this and finds that the gain dies under a frequency-dependent wavelet phase and misses the margin under unit-dependent rock physics, and that a two-mode label error reverses the learned band polarity as predicted). Two pre-registered field tests (F3, 4 wells; Volve, 6 wells) failed their gates, and the authors argue, via a power analysis under their simulator, that neither could have detected the effect, and that Teapot Dome lacks adequate references. Claimed contributions: C1 theory, C2 benchmark package with scorer, C3 RML as a unifying family of baselines, C4 detectability conditions plus audits of public datasets. ## 2. Significance and fit for Computers & Geosciences The fit is good. C&G readers will value: the released task package with hidden truth and a locked scorer; the reproduction package; the unification of shift-tolerant losses, soft-DTW and point-tie training under one loss; and two data-handling findings that every F3/Volve ML user should know — that the F3 "PHIE" at three of four wells is an exact linear transform of sonic (so most published "porosity prediction on F3" is sonic prediction), and that the Volve ST10010 trace headers carry a time scalar that shifts the cube 8 ms if read naively. The two-mode (cycle-skip) result — that a mis-tied subset of wells trains the network toward the wrong polarity in a predictable band, and that carrying both candidate ties fixes it — is the single most practitioner-relevant empirical result and is well presented. What limits the significance for practitioners is that (i) the positive results come from one simulator in which the registration model is, in the nominal cells, the data-generating model, and the one realistic departure in wavelet phase removes the gain; (ii) the headline 8–22% improvement is largely a better tie estimator (SMC with a physical likelihood and phase estimate versus local correlation shifts), not the marginalization that the paper is about; (iii) the two field tests are limited as much by design choices as by the data; and (iv) the "limits of field validation" conclusion is derived for one scoring metric that is maximally sensitive to reference timing. These are the subjects of the major comments. The paper is unusually candid about its negative results and deviations, which I appreciate, and none of my comments require new field data. ## 3. Major comments **M1. The synthetic benchmark is a best case for seismic-band skill, and the paper should say what in it is an inverse crime (Sec. 3.2, Sec. 6.2, Sec. 7 "One simulator").** In the nominal cells the registration uses exactly the simulator's wavelet (a 128 ms zero-phase statistical wavelet up to a constant phase), its rock physics, its warp-prior family and its anchor-noise model (independent N(0, 7^2 ms) per anchor). Seismic is a deterministic function of porosity plus white Gaussian noise: no lithology or fluid confounder, no coloured or coherent noise, no multiples. The porosity field has in-band standard deviation of roughly 1.3 p.u. (from Table 1: band RMSE 0.426 at PCC 0.954 and sd ratio 0.945). The Oracle reaches band PCC 0.95; on F3 no method reaches 0.25. The S2 presets help, but they are narrow: the rock-physics preset only rescales the DT intercept per unit (no scatter in the phi–DT relation, which is the dominant real-world effect), and the anchor error structure is never varied even though the paper's own F3 audit says the anchors are horizon-tie picks whose errors are correlated with the seismic and across wells. The anchor noise model therefore favours the registration relative to F3. Two further points are unstated: whether the noise is independent across the nine traces of the 3x3 patch and whether the earth model varies laterally within the patch (if the model is laterally smooth and the noise independent, the effective SNR seen by the network is about 9.5 dB higher than the nominal "R10/R0/Rm5"). *Why it matters:* the benchmark is the only source of positive evidence; readers need to know how much of its headroom is inverse crime. *What would resolve it:* a short table listing, for each simulator component, whether the registration knows it exactly, approximately, or not at all; the lateral model and noise correlation of the patch; one anchor-error stress (a per-well bias plus correlated pick error, e.g., a common horizon mis-pick) in S2 or in a disclosed arm; and a rock-physics preset with scatter around phi–DT rather than a unit intercept scaling. If these cannot be run, the abstract and Sec. 7 should state the inverse-crime nature of the nominal cells explicitly rather than only "one simulator". **M2. The motivating magnitude of the timing error is a straw man, and the F3 anchors on which "F3-like drift" is calibrated are of unknown quality (Sec. 1 para. 3; Sec. 3.1; Fig. 1).** "Integrating the sonic from the first log sample, as is common in learning studies, gives TWT that differs from the TD markers by up to 14–66 ms" is cited to nothing. No competent workflow integrates sonic from a single shallow anchor; a marker- or checkshot-calibrated tie leaves residuals of a few ms, which is also what the paper's own B3b/B3c-R show on the synthetic (RMS warp error 3.5–7 ms). The one-to-several-period error in the introduction and the "less than 7% of seismic-band variance" statement in Sec. 4.1 therefore describe a mistake, not a tie. Second, the "F3-like" drift level (c = 1) and sigma_a = 7 ms are calibrated on the F3 marker tables. The paper notes that a type-II fit gives sigma_a = 0.4 ms and that leave-one-anchor-out z^2 is 0.21: both say the markers are far smoother than independent picks would be, which suggests they were themselves generated from a smooth time–depth curve. Fig. 1 also shows at F06-1 a kink near 1030 ms common to all three TD sources relative to the markers, which points to a marker (or sonic) problem at that well; a −66 ms sonic offset changing by 45 ms within 500 ms of shallow unconsolidated section is a 9% velocity difference and deserves comment (washout? wrong datum?). Finally, "robust spread (MAD) ... 6.9 ms" — is this the raw MAD (then sigma is about 10 ms) or the scaled one? *What would resolve it:* cite the learning studies that integrate from one anchor or drop the sentence; state the residual of a marker-calibrated tie as the realistic magnitude; say what the F3 markers are (did the authors check NLOG for genuine checkshot/VSP surveys for F02-1, F03-2, F03-4, F06-1?); discuss the F06-1 kink; and state how sensitive the warp prior (m_g, sigma_g, l) and hence c = 1 are to dropping F06-1. **M3. The field tests are limited by design choices as much as by the data, and the paper attributes the lack of skill only to the data (Sec. 6.7; App. B; Sec. 7 "What the field cases show").** (a) Nested LOWO on four wells trains a 64-channel dilated-CNN + bidirectional GRU on *two* wells of 126 samples. The simplest baseline (ridge on attributes, Table B.1) has the best band PCC on F3. The tie comparison was never carried through a model with a capacity matched to the data. (b) The input is "z-scored per channel within each well" (Sec. 5.5). On Volve the error is dominated by between-well porosity level (well means 8.5–17 p.u.), and per-well z-scoring discards exactly the relative amplitude information that would carry between-well impedance level. The "no method had blind-well skill" result is partly induced by preprocessing; a global (survey-wide) normalization arm is cheap and should be reported. (c) B1 (model-based impedance inversion with a well-interpolated LFM, then linear phi–impedance) has band PCC −0.02 against a label that is an exact function of DT, with RHOB itself a linear function of DT, so impedance is a deterministic function of the label. A model-based inversion with a negative in-band correlation to such a label has not been competently set up (wavelet? LFM? tie?), and the paper gives no details. (d) Several published F3 studies report high porosity-prediction skill; the paper should state plainly that those results are typically not blind-well and that the F3 label is a sonic transform, otherwise readers will see the discrepancy and distrust this paper's field numbers. *What would resolve it:* a global-normalization arm on Volve (and F3); carrying the tie comparison through ridge/B0b or a small 1-D CNN on F3; full description of B1 and either a corrected B1 or a statement of why it fails; one paragraph relating to the F3 literature. I am not asking for new wells. **M4. "The limits of field validation" rests on one scoring rule that is maximally sensitive to reference timing (Sec. 4.5, Sec. 6.6, Sec. 7, title, abstract).** The ~1 ms reference requirement and the N* numbers (Table 9) are properties of scoring band RMSE above 6 Hz against a single point reference, with the 8–22% effect of the benchmark. The authors cite tolerance-aware metrics (Guillon et al. 2020; Mnih & Hinton 2012) in Sec. 2 and even score F3 against 64 posterior warps of the test well in App. B (c), but T3 uses neither. Practitioners validate ties and predictions with (i) bounded-lag or tolerance scores, (ii) scoring against the test well's own tie posterior (marginalizing the reference error, which Prop. 6 shows is additive and whose covariance with the prediction they could model), (iii) depth-domain or layer-averaged comparisons that are insensitive to few-ms shifts. Corollary 4 itself says shrinkage relaxes the condition. Also, VSP/checkshot references accurate to 1–2 ms after datum/static reconciliation are routine, so "field data lack them" (highlights) is a statement about the three public datasets examined, not about field validation. *What would resolve it:* rerun T3 with at least one tolerance or posterior-marginalized scoring rule and report how N* changes; rephrase the title/abstract/conclusion from "limits of field validation" to the limits under point-reference band scoring on the public datasets examined. **M5. The headline positive result is a better tie estimator, not marginalization, and the point-tie baselines are under-described (Sec. 6.2 H2a; Sec. 5.3; Table 3).** B3d-Sa's 8–22% gain is "already present without drift" (ratios 0.81–0.88 at c = 0). At c = 0 the only differences between B3d-Sa and B3c/B3c-R are the tie estimator (SMC with a physical likelihood, profiled amplitude and a phase scan versus local NCC shifts): SMC warp RMSE 0.6 ms versus 3.5–4.2 ms for B3c-R at R10. The practical message — the quality of the tie algorithm dominates, and the bank adds 2–11% only when the posterior is wide — is buried under the RML framing. Moreover B3c ("B3b plus local shifts from synthetic–seismic correlation") is described in one line: window length, maximum shift, smoothing, and whether shifts are constrained to be monotone and to honour anchors are not given, so I cannot judge whether it is a competent stretch-and-squeeze baseline or a weak one. There is also no interpreter-style tie (anchors as knots, global phase and bulk-shift scan, interpolated stretch) among the point ties, which is what most practitioners actually use. *What would resolve it:* state the finding up front; one table of warp RMSE and 90% coverage per tie method per regime at c in {0, 1}; a full description of B3c/B3c-R; and, if feasible, an interpreter-style point tie as a competitor. Note that the sigma_a arm (Table 5) shows the SMC tie itself, not only the bank, is fragile to a twofold error in sigma_a; this should be stated as a property of the tie estimator. **M6. Where the predictors have skill in frequency does not match the blur mechanism, and this should be made explicit (Sec. 4.1 H1 limitations; Sec. 4.3 "Finite samples"; Sec. 6.5 S8).** H1 only tests 6.8–22.5 Hz "where the MSE predictor has coherent power (72% of the in-band cross-spectrum)", while the F3 seismic peaks at 43–62 Hz. At 20 Hz a Gaussian tie error of 3 ms attenuates by 7% and of 1 ms by under 1%, so the population blur (C1) cannot produce the 8–22% band-RMSE gains observed at posterior widths of 0.6–2.5 ms; the paper says in passing that first-order label noise ("finite samples") is the operative term. The '7% of seismic-band variance retained at sigma = 8 ms' in Sec. 4.1 uses the F3 amplitude spectrum as proxy, but the predictors recover a band where the same error keeps about 36%. Readers will otherwise take C1 as the explanation of the empirical gains. *What would resolve it:* show the cross-spectrum of Oracle predictions with the labels (where skill lives), state that no method exploits the 40–60 Hz band, quantify the first-order label-noise term for the H2a cells, and say that H1 verifies the blur law but that the main empirical gains are finite-sample effects on label noise and tie accuracy. **M7. Pre-registration is self-certified; the wording should match (Sec. 6 opening; App. B "Protocol and deviations").** The protocol of Exp. 1 was committed after its run, those of F3 and Volve after their runs, that of Exp. 3 during; the timing record is a time stamp inside a lock file written by the authors' own scripts. Hash-locking is good engineering, but "pre-registered" in the abstract and highlights implies an external record. Either deposit the protocols with an external timestamp (OSF, Zenodo) for the locked files that still exist, or use "hash-locked" in the abstract and state the self-certification there. ## 4. Minor comments - m1. The submitted source contains editorial material that must not reach a referee or a reader: red TODO blocks (author list; Sec. 2 novelty todoblock referring to internal `docs/plan.md`; data/code DOIs; Teapot licence; Computer code availability; declarations; generative-AI statement). C&G requires the Computer code availability section. - m2. Naming: the manuscript calls RML "registration-marginalized learning"; the benchmark README (Sec. 6) calls M2-Sa "regression with misregistered labels (RML)". Align. - m3. Sec. 3.3 says "only F-11 T2 has a zero-offset VSP"; Sec. 6.7 says "Volve has check shots at two wells". Reconcile and name the wells. - m4. Sec. 7 "closed 29–35% of that gap" versus Sec. 6.4 "30–35%". - m5. Sec. 4.2 "4 wells of 16 anchors" versus Sec. 3.1 "9–11 anchors in the target window" (presumably 16 counts the extended window; say so). - m6. Sec. 3.2 should state that the true warps are drawn with sigma_b = 19 ms (ML fit) while registration fixes sigma_b = 50 ms, and whether c scales b from 19 or 50. - m7. Missing references a QI reader will expect: White & Hu (1998, *The Leading Edge*, "How accurate can a well tie be?") and White & Simm (2003, *First Break*, "Tutorial: Good practice in well ties") on well-tie accuracy and the stretch/phase trade-off; Stewart, Huddleston & Kan (1984, *Geophysics*) on sonic–seismic drift; Box & Lowrey (2003, *TLE*) on reconciling sonic with checkshots; Walden & White (1998) on wavelet estimation as a noisy input–output problem; and, for learned property prediction from few wells, Das & Mukerji (2020, *Geophysics*) and the Mustafa/Alfarraj/AlRegib TCN impedance work, since a TCN is used here. - m8. Fig. 1 legend "DT model" versus text "a second set of model files": name the files/sources so that readers can reproduce the comparison. - m9. Fig. 13 (F3 volume): strong vertical striping in (a) around crosslines 800–1000 and no lateral coherence; the 27–32 p.u. colour range shows the prediction barely varies. Either comment (per-trace prediction with per-well z-scoring) or drop the figure. - m10. Table 7: 1/B_b values of 0.132 and "<0.001" are not meaningful (sharpening by exp(+2 pi^2 sigma^2 f^2) at sigma = 4–11 ms amplifies Oracle estimation noise). State that the Berkson bound is undefined at large sigma rather than tabulating it. - m11. Abstract: "The first comparison failed, and the second was designed after that failure" appears before the comparisons are defined; readers cannot tell which comparison. Reorder. - m12. Sec. 3.3: give the cube name (ST10010 ... PSDM ... FULL_T) and the header scalar value so the 8 ms fix is reproducible; state the SEG-Y reader used. - m13. Sec. 3.1: give the mean and standard deviation of PHIE_DT in the window (about 30 p.u. judging from Fig. 13) so that band RMSE of 1.2 p.u. can be put in context. - m14. Table 2 (positioning): "Reg. eval." is ticked for this work, but on field data no registration-aware evaluation was applied; qualify. - m15. Sec. 5.5: the TCN selected the smallest budget (125) in every method; extend the candidate set downward or note that the boundary choice suggests over-fitting at the smallest budget. - m16. Sec. 6.6: the critique of k-of-n gates is correct, but the gates were the authors' own; say so. - m17. Lemma 5: with NLL cells of order one, lambda = 2/gamma = 20 is effectively the hard minimum; a sentence on how gamma = 0.1 was chosen for B4c would help. - m18. Sec. 3.2: the OU correlation length of 2 ms is below the 4 ms sampling; say how the field is sampled and anti-aliased. ## 5. Questions to the authors - Q1. Is the additive noise independent across the nine traces of the 3x3 patch, and does the earth model vary laterally within the patch? What is the effective SNR after patch averaging? - Q2. What are the F3 "TD markers"? Were they picked individually, or derived from a smooth time–depth curve (the type-II sigma_a = 0.4 ms and leave-one-anchor-out z^2 = 0.21 suggest the latter)? Did you check NLOG for actual checkshot/VSP surveys at these four wells? What explains the F06-1 kink near 1030 ms? - Q3. What happens on Volve (and F3) with survey-wide rather than per-well normalization of the seismic input, and with a per-well amplitude level retained as a feature? - Q4. Please give the full specification of B3c (window length, maximum shift, smoothing, monotonicity, anchor honouring). Would an interpreter-style tie (anchors as knots, global phase/bulk scan, interpolated stretch) differ from B3b/B3c in warp RMSE? - Q5. Where does the cross-spectrum between Oracle predictions and labels sit? Does any method exploit the 40–60 Hz band? If not, how do you reconcile 8–22% gains with sub-percent blur at the frequencies where skill lives? - Q6. How do the N* values of Table 9 change under a bounded-lag tolerance score or under scoring against the test well's tie posterior? - Q7. Teapot: the 6.6 ms per-well bulk residual resembles datum/static error. Did you try the survey datum, replacement velocity and elevation information before concluding that the reference cannot reach 1.5 ms? - Q8. The bank helps most at R10tb, where the posterior is overconfident and Ctl-GP (a Gaussian jitter around the mean warp) matches M2-Sa at c = 1. Would a plain shift-jitter augmentation of the B3c-R labels — the cheapest practitioner option — obtain the same gain? Was it tried? - Q9. Under the mixed-phase wavelet (wv_L1), would a two-parameter (constant + linear) phase in the SMC restore the posterior coverage and the gain? This determines whether the failure is fundamental or a model-capacity issue in the tie. - Q10. How sensitive are the H2b results to lambda? The only ablation (lambda = 1 on F3, Table B.5) changes band RMSE by 1%; was lambda varied on the synthetic grid? ## 6. Recommendation **Major revision.** The theory is sound as far as I checked it, the audits of F3 and Volve are valuable, the benchmark and reproduction packages are a genuine service, and the authors' candour about negative results is exemplary. But the paper's positive evidence comes from a simulator whose nominal cells are an inverse crime, its headline gain is a better tie estimator rather than the marginalization it advertises, its field tests are limited by design choices (model capacity, per-well normalization, an unexplained inversion baseline) that the text attributes only to the data, and its "limits of field validation" are derived for a single scoring rule. All of this can be fixed with reruns on existing data, added baselines/arms, and rewording; none requires new wells. Confidence: **high** for the data-handling, baseline and field-validation comments (my area); **medium** for the theory, where I checked the main derivations and the numerical constants and found no error but did not verify every step of Appendix A.