\begin{abstract} Seismic reservoir-property predictors are trained on well logs placed in two-way time by uncertain well ties. Treating tie error as an error in the time index of the labels, we show that errors independent of the data blur the optimal predictor, attenuating the seismic band; a controlled experiment matched the predicted blur to within 1\% below 23\,Hz. In a linear-Gaussian model a posterior-mean tie is predicted to sharpen the predictor, but where testable the trained network was blurred. A calibrated bank of posterior labels can gain over the posterior-mean tie only a fourth-order amount in population. We release a synthetic benchmark of F3 statistics with known true timing and a scorer. With a correctly specified tie model and dense anchors of known uncertainty, labels at the mean of a sequential Monte Carlo tie posterior reduced seismic-band RMSE by 8--22\% relative to the best deterministic tie and by 2--33\% relative to an anchor-only posterior mean. It comes mainly from a more accurate tie model: the mode of the same posterior gave most of it and averaging added at most 3\%. Training on posterior samples added 2--11\% when the posterior was wide, but a Gaussian bank with the same two moments obtained most of that. Field validation remains open: F3 and Volve showed no consistent improvement, and, for effects like those of the benchmark, an exploratory power analysis suggests a blind-well comparison needs 5--18 wells with an exact reference in most cases and more than 40 with a 3\,ms reference error. \end{abstract} \noindent\textbf{Keywords:} well tie; tie uncertainty; registration error; errors-in-variables; seismic porosity prediction; synthetic benchmark; blind-well validation; statistical power