\section{Data and audit} \label{sec:data} \subsection{F3 block} \label{sec:data:f3} We use the public F3 Demo 2023 release of the F3 block, Dutch sector of the North Sea, distributed by dGB Earth Sciences as an OpendTect project under a CC BY-SA 3.0 licence \citep{dgb2023f3demo}. The post-stack volume covers inlines 100--750 and crosslines 300--1250 at 4\,ms sampling. Four vertical wells have sonic (DT), density (RHOB) and effective porosity (PHIE) logs: F02-1, F03-2, F03-4 and F06-1. The release also contains seven interpreted horizons and time--depth (TD) markers at each well. All learning experiments use the window 600--1100\,ms TWT (126 samples). Tie likelihoods and anchors use the extended window 400--1300\,ms. Within the target window, the amplitude spectrum of the volume peaks near 60\,Hz (43--62\,Hz around the wells), with a mean frequency of 49\,Hz. The dominant period is therefore 17--20\,ms. The $-20$\,dB band of the volume spans 4--83\,Hz. We audited the well data before any modelling. Table~\ref{tab:audit} summarizes the findings, and the paragraphs below explain them. \begin{table}[t] \centering \caption{Audit of the F3 wells in the 600--1100\,ms window. $\Delta t_{\mathrm{DT}}$: TWT from integrated sonic minus TD-marker TWT, over the markers in the window (range, and change within the window). $\max|\Delta t_{\mathrm{wlt}}|$: largest deviation of the distributed OpendTect time--depth model from the markers. $K$: TD markers in the window. Label: relation of PHIE to the logs.} \label{tab:audit} \small \setlength{\tabcolsep}{3pt} \begin{tabular}{lcccccl} \toprule Well & IL/XL & $\Delta t_{\mathrm{DT}}$ (ms) & change (ms) & $\max|\Delta t_{\mathrm{wlt}}|$ (ms) & $K$ & Label \\ \midrule F02-1 & 362/336 & $+2 \to -44$ & 46 & 28.6 & 11 & from RHOB ($R^2=0.84$) \\ F03-2 & 722/848 & $-3 \to -14$ & 11 & 9.6 & 9 & $-0.2018+0.0011\,\mathrm{DT}$ \\ F03-4 & 442/1007 & $-42 \to -52$ & 10 & 8.8 & 9 & $-0.2018+0.0011\,\mathrm{DT}$ \\ F06-1 & 244/387 & $-21 \to -66$ & 45 & 36.5 & 10 & $-0.2018+0.0011\,\mathrm{DT}$ \\ \bottomrule \end{tabular} \end{table} \paragraph{Geometry.} We located the wells by applying the survey's bin-to-coordinate transform to the wellhead coordinates. F02-1 and F06-1 are 3.2\,km apart, and the other pairs are 8--17\,km apart. The distance to the nearest training well therefore differs greatly between leave-one-well-out folds. \paragraph{Time--depth relation.} Integrating the sonic from the first log sample, as is common in learning studies, gives TWT that differs from the TD markers in the window by up to 14--66\,ms, depending on the well. The difference changes with depth by 10--46\,ms (Table~\ref{tab:audit}, Fig.~\ref{fig:tddrift}). The sign is negative at depth, so sonic time is early, as expected from velocity dispersion. The two TD models distributed with the data also disagree. The OpendTect model deviates from the markers by up to 36.5\,ms. A second set of model files is offset from the check-shot tables by $+40.5$, $+40.2$, $+25.2$ and $-14.6$\,ms on average. The sign and size of this offset vary by well, and at F06-1 it changes sign with depth. A datum correction does not explain it. The ``check-shot'' tables have exactly the same depths as the markers. They are horizon-tie picks made on this seismic volume, not independent check-shot surveys. We therefore treat them as anchors with a pick uncertainty $\sigma_a$. The robust spread (MAD) of marker--horizon time differences over 18 pairs at the four wells is 6.9\,ms, and we use $\sigma_a = 7$\,ms. Each well has 9--11 anchors in the target window, 8 to about 148\,ms apart. \begin{figure}[t] \centering \includegraphics[width=\linewidth]{td_drift.pdf} \caption{Offset of three time--depth sources from the TD markers at the four F3 wells: sonic integrated from a single shallow anchor (integrated DT), the distributed OpendTect time--depth model, and a second distributed model (DT model). The shaded band is the 600--1100\,ms target window.} \label{fig:tddrift} \end{figure} \paragraph{Labels.} At F03-2, F03-4 and F06-1, PHIE is an exact linear function of the sonic log: $\mathrm{PHIE} = -0.2018 + 0.0011\,\mathrm{DT}$ (DT in $\mu$s/m, $R^2 = 1.00000$, maximum error $10^{-4}$). It is equally exactly $(2650 - \mathrm{RHOB})/1600$. The density at these wells is itself derived from sonic: a national well-log archive shows that the density at F03-4 and F06-1 is a predicted log, and the measured density at F03-2 starts below the target window. At F02-1, PHIE follows the measured density ($R^2 = 0.84$) but is not a deterministic function of it. To give all four wells the same label definition, we use $\mathrm{PHIE}_{\mathrm{DT}} = -0.2018 + 0.0011\,\mathrm{DT}$ at all wells and report the original PHIE as a sensitivity check. The F3 ``porosity'' target in this paper is therefore a linear transform of sonic slowness. We call it porosity only in this sense. Density porosity computed from measured density explains 27--59\% of the variance of this label at four wells with measured density in the window (F02-1, F03-4 and two archive wells outside the release). Choosing the label is therefore choosing what is learned. There is one benefit: the rock-physics chain $\phi \to \mathrm{DT} \to \mathrm{RHOB} \to$ acoustic impedance is known exactly, so the physical tie likelihood of Section~\ref{sec:method} is not an approximation on F3. \subsection{Synthetic benchmark (D2)} \label{sec:data:d2} The synthetic benchmark makes the true registration known while keeping the F3 statistics. Five F3 horizons (Shallow, FS8, FS7, Truncation, MFS4) define the stratigraphic frame. Porosity is a trend ($\phi_0 = 0.32$, slope $-0.008$ per 100\,ms) plus unit offsets and a sum of two Ornstein--Uhlenbeck fields in stratigraphic coordinates (standard deviations 0.010 and 0.006, correlation lengths 10 and 2\,ms), clipped to $[0.05, 0.45]$. The F3 rock physics maps porosity to DT, RHOB and impedance. Seismic is the reflectivity convolved with a 128\,ms zero-phase statistical wavelet estimated from F3, plus noise at a prescribed signal-to-noise ratio (SNR). The true time--depth warp of each well is drawn from the warp prior of Section~\ref{sec:method:prior}, fitted to the F3 anchors, and scaled by a drift factor $c$ ($g \to c\,g$, $b \to c\,b$). $c = 1$ reproduces the F3 drift level, and $c = 0$ is perfect registration. Anchors are the true times at stratigraphic markers plus $\N(0, \sigma_a^2)$ noise with $\sigma_a = 7$\,ms. Each realization has a pool of 16 training wells, from which nested subsets of $N$ wells are drawn, and 8 test wells at least 1\,km from every other well. Labels are scored in the true time of the earth model. We use five observation regimes: \begin{itemize} \item R10, R0 and Rm5: SNR 10, 0 and $-5$\,dB, full anchor density; \item R0h: SNR 0\,dB with half the anchors; \item R10tb: SNR 10\,dB with only the top and bottom anchors. \end{itemize} Under the F3 warp prior, Rm5 gives the posterior width closest to F3 (Section~\ref{sec:exp:p2r}). \paragraph{Misspecification (Experiment~3).} Study S2 generates the data with a simulator that departs from the model used for registration, which keeps the nominal rock physics, a statistical wavelet with a constant phase, and the warp prior of Section~\ref{sec:method:prior}. There are three axes, each at two levels (Table~\ref{tab:s2}). Rock physics: the DT intercept (matrix slowness) is scaled in each stratigraphic unit by $1 + s\zeta_u$, $\zeta_u \sim \N(0, 1)$, with $s = 0.10$ (L1, about $\pm 18\,\mu$s/m) or $0.15$ (L2). Wavelet: the phase spectrum is half (L1) or all (L2) of the minimum-phase spectrum of the nominal amplitude spectrum; a separate cell, wv\_Q, applies constant-$Q$ attenuation ($Q = 80$ from 400\,ms, with dispersion), which lowers the peak frequency from 59 to 32\,Hz across the window. Drift: the true warps are drawn with scaled prior hyperparameters (bulk-offset standard deviation $\times 3$, which exceeds the value fixed in the registration, drift standard deviation $\times 1.5$ and correlation length $\times 0.5$; L1), or with components outside the prior's family (an 8\,ms step just below Truncation plus jitter with standard deviation 1\,ms and correlation length 8\,ms; L2). The size of a seismic misspecification is measured by its model error: the RMS residual between the clean seismic and the best synthetic in the registration's model family at the true warp, divided by the RMS of the noise at R10. It is 0.23 for the nominal simulator and 1.08--1.93 for the five seismic presets. The levels were chosen on development realizations 902--905. The declared target for L1 was 0.5--1.0 times the R10 noise, and both L1 levels lie above it. For the phase no milder level exists: a quarter of the minimum-phase spectrum (model error 0.62) already reduced the 90\% warp coverage to 0.25 on development data. For rock physics, milder levels changed the registration too little to be told apart, so the level was set by model error. Uniform errors in the rock-physics coefficients, a constant phase rotation and a shift of the peak frequency are absorbed by the registration's profiled amplitude and constant-phase fit; they were run on development data only, as controls. At Rm5 the noise RMS is 1.78 times that of the signal and the model errors are 0.19--0.34 of the noise, so the protocol declared in advance that registration at Rm5 should be unaffected. \subsection{Volve field} \label{sec:data:volve} The second field dataset is Volve (Norwegian North Sea), released by Equinor in 2018 \citep{equinor2018volve}; the licence files of the release name CC BY-NC-SA 4.0. Its role is to break the label structure of F3. The computed effective porosity PHIF of the operator's petrophysical interpretation is driven by density, not by sonic: within each well its correlation with RHOB is $-0.92$ to $-0.99$, RHOB and NPHI explain 84--98\% of its variance, and adding DT raises this by at most 0.9 percentage points. Six wells have DT, RHOB, NPHI and PHIF: F-1, F-1 A, F-1 B, F-11 A, F-11 T2 and F-12. All six are deviated (maximum inclination 30--82$^\circ$; 4--54$^\circ$ over the labelled interval), and they share one platform. F-1 A and F-1 B leave the F-1 borehole at 2587\,m MD, and F-11 A leaves F-11 T2 at about 2580\,m MD, so the wells form three slot groups, \{F-1, F-1 A, F-1 B\}, \{F-11 A, F-11 T2\} and \{F-12\}, whose members share the hole above the kick-off. \paragraph{Seismic and geometry.} We use the post-stack ST10010 full-angle stack (3--41$^\circ$), a 2011 depth migration converted to time, at 4\,ms sampling. Its trace headers carry an invalid time scalar that standard readers apply to the start time, which shifts every sample 8\,ms late. We use the start time of the text header (4\,ms) and checked it against five interpreted horizons: the amplitude extremum along each falls at a lag of 0 to $+2$\,ms. Trajectories come from the operator's definitive surveys; recomputing them by minimum curvature reproduces the listed TVD within 0.01\,m. The seismic input of a well is a $3\times3$ patch of traces interpolated bilinearly along the deviated path at the time given by its time--depth relation, because a vertical trace at one bin differs from the path composite by a relative RMS of 0.19--0.61 over the labelled interval. Learning uses the window 2400--2900\,ms (126 samples) and tie likelihoods the extended window 2000--3200\,ms. \paragraph{Time--depth and anchors.} Of the six wells, only F-11 T2 has a zero-offset VSP. As anchors we use the operator's well picks with a TWT from the Ty Formation downwards, excluding picks flagged as not logged, not reached or faulted; each well has 4--9 such anchors within its logged sonic interval. Shallower picks are unreliable (picks at the same depth in a shared borehole differ by about 110\,ms). At reservoir level every unflagged pick lies within $\pm 10$\,ms of the corresponding interpreted horizon, and at F-11 T2 the picks lie within $-6.1$ to $+2.3$\,ms of the VSP. The pick times come from the operator's time--depth models, so they are interpretations, not measurements, as on F3. Time is vertical time: DT is integrated over TVD and calibrated to the anchors by stretching between them. At F-11 T2 this marker-calibrated sonic lies within $-2.4$ to $-0.8$\,ms of the VSP over the labelled interval. We keep $\sigma_a = 7$\,ms from F3; it is not estimated on Volve. \paragraph{Labels.} PHIF is used only where DT is valid, which leaves 16--37 labelled 4\,ms samples per well (150 in total) at 2509--2819\,ms. The labelled runs lie 25--179\,m below the deepest anchor, so their timing depends on the drift of the sonic below it. They are shorter than one period at 6\,Hz, so the band split used on F3 is undefined here. The well means of PHIF range from 8.5\,p.u.\ at F-1 to 17.0\,p.u.\ at F-12, against standard deviations of 3.3--6.0\,p.u.\ within wells.