P4 (Volve field case). Add the deviated-well and Volve well builders (ml_porosity/data/deviated.py, volve_wells.py), the ml_porosity/volve/ pipeline, scripts 23-25, the run_p4 drivers and tests. The protocol configs/protocol_volve.yaml was locked at 2026-10-29T01:17:42Z before the run (.sha256, .lock.json) and is committed here after the run. Gate G-D failed: M2-Sa beats the selected B3 at 2/6 wells (lowo) and 3/6 (slot), coverage90 is about 0.47, and no method has blind-well skill (R2 < 0). A post hoc constant at the training-well mean beats every network, so G-D had no power. The dropped P4x exploratory run is kept as a record only (exploratory/, docs/research/p4-exploratory.md). Applicability and Teapot Dome (exploratory, pre-declared). Scripts 26-29 and docs/research/applicability-*.md: F3 and Volve fail C1 and pass C2; T3 power needs 5-18 blind wells with an exact reference; Teapot T0 and pilot P-a failed, so Teapot is stopped. Raw Teapot data stay gitignored. Manuscript (Pivot 1, level A). Reframe paper/ as a theory and synthetic benchmark paper: Propositions 3-6, Corollaries 3-4, T4 coverage (script 30) and the post hoc H2b bound check (script 31), with F3/Volve moved to Appendix B. Correct two earlier claims: the Berkson and classical bounds differ by 1.5-4.6x at the f^4-weighted band, and the bank gain exceeds the registered classical bound (7/8 wide cells at N = 16) but only 3/8 under the post hoc Berkson bound. Docs. Sync plan, AGENTS.md, README, report.html, theory and technical overview. The length pass for the venue is dropped by the user (plan section 12 item 25); the length risk stays recorded as R9. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
6 lines
1.9 KiB
TeX
6 lines
1.9 KiB
TeX
\begin{abstract}
|
|
Seismic reservoir-property predictors are trained on well logs that a well tie places in two-way time, and the tie is uncertain. We analyse its error as an error in the time index of the label. Under an independence assumption, misregistered labels convolve the optimal predictor with the error distribution and blur the seismic band, as a controlled experiment confirmed to within 1\%. Without time anchors, absolute timing is not identified. A tie computed as a posterior mean has the opposite, Berkson, error structure and sharpens the predictor instead. A calibrated bank of posterior labels attains the oracle's population optimum, but its population gain over a point label is of fourth order in the tie error. On a registration-aware synthetic benchmark calibrated to F3, we compared point ties, posterior-mean labels and a tempered likelihood over a posterior bank under pre-registered rules. The first comparison failed, and the second was designed after that failure. There, posterior-mean labels had 8--22\% lower seismic-band RMSE than the best point tie, but failed when the anchor uncertainty was set at half or twice its true value. The bank gained further in all eight cells with a wide posterior. This gain exceeded the registered population bound for classical tie error in seven cells, but a post hoc bound for Berkson error in only three. Detecting such gains at blind wells requires an accurate reference: with exact ties, 5--18 wells gave a power of 0.8 in most cells; with reference errors of 3\,ms or more, 40 wells did not. The F3 and Volve field tests (four and six wells) failed, and neither could have detected such gains. Teapot Dome has independent time--depth references at no more than two of its 152 wells. We make no field or calibration claim.
|
|
\end{abstract}
|
|
|
|
\noindent\textbf{Keywords:} well tie; registration error; errors-in-variables; seismic porosity prediction; synthetic benchmark; blind-well validation; statistical power
|