Complete P4 Volve; pivot the manuscript to theory + benchmark
P4 (Volve field case). Add the deviated-well and Volve well builders (ml_porosity/data/deviated.py, volve_wells.py), the ml_porosity/volve/ pipeline, scripts 23-25, the run_p4 drivers and tests. The protocol configs/protocol_volve.yaml was locked at 2026-10-29T01:17:42Z before the run (.sha256, .lock.json) and is committed here after the run. Gate G-D failed: M2-Sa beats the selected B3 at 2/6 wells (lowo) and 3/6 (slot), coverage90 is about 0.47, and no method has blind-well skill (R2 < 0). A post hoc constant at the training-well mean beats every network, so G-D had no power. The dropped P4x exploratory run is kept as a record only (exploratory/, docs/research/p4-exploratory.md). Applicability and Teapot Dome (exploratory, pre-declared). Scripts 26-29 and docs/research/applicability-*.md: F3 and Volve fail C1 and pass C2; T3 power needs 5-18 blind wells with an exact reference; Teapot T0 and pilot P-a failed, so Teapot is stopped. Raw Teapot data stay gitignored. Manuscript (Pivot 1, level A). Reframe paper/ as a theory and synthetic benchmark paper: Propositions 3-6, Corollaries 3-4, T4 coverage (script 30) and the post hoc H2b bound check (script 31), with F3/Volve moved to Appendix B. Correct two earlier claims: the Berkson and classical bounds differ by 1.5-4.6x at the f^4-weighted band, and the bank gain exceeds the registered classical bound (7/8 wide cells at N = 16) but only 3/8 under the post hoc Berkson bound. Docs. Sync plan, AGENTS.md, README, report.html, theory and technical overview. The length pass for the venue is dropped by the user (plan section 12 item 25); the length risk stays recorded as R9. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -1,11 +1,5 @@
|
||||
\begin{abstract}
|
||||
Supervised prediction of reservoir properties from post-stack seismic data needs well logs in two-way time. Such labels exist only after a well tie, and the tie is uncertain. In the F3 block (Netherlands North Sea), sonic-integrated times at the four public wells differ from the time--depth markers by up to 14--66\,ms, and the difference changes by 10--46\,ms within a 500\,ms target window. These errors exceed the 17--20\,ms dominant period of the data. Standard workflows nevertheless collapse the tie to a single time--depth curve before training.
|
||||
|
||||
We analyse what this does to a learned predictor. Under an independence assumption, the MSE-optimal predictor trained on misregistered labels is the correctly registered predictor convolved with the distribution of the timing error (Proposition~1). The seismic-band content is therefore attenuated by the characteristic function of that error. A controlled experiment with known Gaussian shifts matches this transfer function to within 1\% for $\sigma \le 16$\,ms. Without time anchors, the absolute timing of a shared network and its label alignment is not identified (Proposition~2). This explains why alignment losses such as soft-DTW and DILATE cannot recover the timing on their own. We then propose registration-marginalized learning (RML): labels are drawn from an anchor- and seismic-conditioned posterior over time--depth warps, and the network is trained with a tempered log-sum-exp loss over this bank. Point-tie training, shift-tolerant losses and soft-DTW are special cases of this loss.
|
||||
|
||||
We test the approach on a synthetic benchmark built from F3 geometry, rock physics and time--depth statistics, under pre-registered pass rules. The first pre-registered comparison failed: an anchor-only posterior with 64 samples did not contract to the true warp, and its labels did not beat the best point tie. We report this failure as it stands. A second pre-registration replaced the registration step with a sequential Monte Carlo tie posterior. Labels at the posterior-mean warp then reduced seismic-band RMSE by 8--22\% relative to the best point tie at F3-like drift, in all three signal-to-noise regimes tested. RML on the particle bank improved further when the posterior was wide: 8 of 8 wide cells passed, and the gain grew with posterior width (Spearman $\rho=-0.85$). These gains require a correctly specified anchor-pick uncertainty: with the anchor uncertainty set at half or twice its true value, no cell passed. Predictive uncertainty from seed ensembles under-covered for every method. We therefore make no calibration claim.
|
||||
On the four F3 wells, a third pre-registered test with nested leave-one-well-out validation failed. RML on the particle bank had lower seismic-band RMSE than the best point tie at one well of four, where three were required, and its 80\% and 90\% predictive intervals covered 52\% and 61\% of the samples. Varying the anchor uncertainty, the scoring reference or the label did not make the test pass. On these wells the differences between methods were smaller than the variation between training seeds.
|
||||
\todo{Volve results (gate G-D) and the final one-sentence conclusion.}
|
||||
Seismic reservoir-property predictors are trained on well logs that a well tie places in two-way time, and the tie is uncertain. We analyse its error as an error in the time index of the label. Under an independence assumption, misregistered labels convolve the optimal predictor with the error distribution and blur the seismic band, as a controlled experiment confirmed to within 1\%. Without time anchors, absolute timing is not identified. A tie computed as a posterior mean has the opposite, Berkson, error structure and sharpens the predictor instead. A calibrated bank of posterior labels attains the oracle's population optimum, but its population gain over a point label is of fourth order in the tie error. On a registration-aware synthetic benchmark calibrated to F3, we compared point ties, posterior-mean labels and a tempered likelihood over a posterior bank under pre-registered rules. The first comparison failed, and the second was designed after that failure. There, posterior-mean labels had 8--22\% lower seismic-band RMSE than the best point tie, but failed when the anchor uncertainty was set at half or twice its true value. The bank gained further in all eight cells with a wide posterior. This gain exceeded the registered population bound for classical tie error in seven cells, but a post hoc bound for Berkson error in only three. Detecting such gains at blind wells requires an accurate reference: with exact ties, 5--18 wells gave a power of 0.8 in most cells; with reference errors of 3\,ms or more, 40 wells did not. The F3 and Volve field tests (four and six wells) failed, and neither could have detected such gains. Teapot Dome has independent time--depth references at no more than two of its 152 wells. We make no field or calibration claim.
|
||||
\end{abstract}
|
||||
|
||||
\noindent\textbf{Keywords:} well tie; time--depth uncertainty; porosity prediction; deep learning; label noise; uncertainty quantification; F3 Netherlands
|
||||