- ml_porosity/benchmark/ runner, scripts 32-35, scripts/run_bench.sh;
misspec= option in synth_d2 (default path reproduces P2r bit for bit).
- configs/protocol_bench.{yaml,sha256,lock.json} locked 29/10 14:39 UTC
(sha256 aa763f0a...), configs/d2_synth_bench.yaml.
- T2 mechanism declaration and results; operations/p6_supervisor.py.
- Docs, report and paper edits of 29/10.
outputs/ stays out of git; the repository folder is synced as a whole to
the new server. Main S1 runs are still training at this commit.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
6 lines
2.0 KiB
TeX
6 lines
2.0 KiB
TeX
\begin{abstract}
|
|
Seismic reservoir-property predictors are trained on well logs that a well tie places in two-way time, and the tie is uncertain. We analyse its error as an error in the time index of the label. Under an independence assumption, misregistered labels convolve the optimal predictor with the error distribution and blur the seismic band; a controlled experiment matched the predicted transfer to within 1\% for errors of 4--16\,ms. Without time anchors, absolute timing is not identified. A tie computed as a posterior mean has the opposite, Berkson, error structure and sharpens the predictor instead. A calibrated bank of posterior labels attains the oracle's population optimum, but its population gain over a point label is of fourth order in the tie error. On a registration-aware synthetic benchmark calibrated to F3, we compared point ties, posterior-mean labels and a tempered likelihood over a posterior bank under pre-registered rules. The first comparison failed, and the second was designed after that failure. There, posterior-mean labels had 8--22\% lower seismic-band RMSE than the best point tie, most of it already without drift, but failed when the anchor uncertainty was set at half or twice its true value. With 16 training wells, the bank gained further in all eight cells with a wide posterior. This gain exceeded the registered population bound for classical tie error in seven cells, but a post hoc bound for Berkson error in only three. Detecting such gains at blind wells requires an accurate reference: with an exact reference, 5--18 wells gave a power of 0.8 in most cells; with reference errors of 3\,ms or more, 40 wells did not. The F3 and Volve field tests (four and six wells) failed, and neither could have detected such gains. Teapot Dome has independent time--depth references at no more than two of its 152 wells. We make no field or calibration claim.
|
|
\end{abstract}
|
|
|
|
\noindent\textbf{Keywords:} well tie; registration error; errors-in-variables; seismic porosity prediction; synthetic benchmark; blind-well validation; statistical power
|