Set up the data, parsing and quality-control layer for a public benchmark on the Volve daily drilling reports (DDR) and WITSML real-time data. - Data manifest with SHA-256 hashes of the three Volve subtrees in use. - DDR XML parser into DuckDB (1,759 reports, 26 wellbores, 23,447 activities, 17 tables) with locked expected counts. - Render QC of the publisher HTML against the XML (272,544 items). - OCR client for the shared chandra vLLM service, with a page cache keyed on model, prompt hash, dpi, max_tokens and temperature, and OCR QC against the HTML on a 26-report pilot. - Run logging (scripts/runlog.sh, logs/index.csv), the P0 runner and 40 tests. - Research plan, technical overview and progress page (in Vietnamese). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
95 lines
3.8 KiB
Markdown
95 lines
3.8 KiB
Markdown
# Optional Figures and Tables
|
|
|
|
Figures and tables are optional. Include a display only when it communicates verified
|
|
evidence more clearly than prose and the target venue permits it. This skill does not
|
|
generate images, schematics, graphical abstracts, or synthetic scientific visuals.
|
|
|
|
## Provenance gate
|
|
|
|
Each display needs a record containing:
|
|
|
|
- stable display ID and version;
|
|
- source data or evidence IDs;
|
|
- code, query, or manual transformation used;
|
|
- accountable creator and reviewer;
|
|
- date generated or revised;
|
|
- analysis population, exclusions, and sample size;
|
|
- units, scales, denominators, and uncertainty definitions;
|
|
- license, attribution, and permission status for reused material;
|
|
- documented adjustments, cropping, compositing, or preprocessing.
|
|
|
|
Do not recreate missing source data from a screenshot or published graphic. Do not
|
|
alter an image in a way that hides, removes, duplicates, or misrepresents information.
|
|
Retain original files and an audit trail.
|
|
|
|
## Choosing a form
|
|
|
|
Use:
|
|
|
|
- prose for a small number of directly relevant values;
|
|
- a table when exact values and multidimensional comparison matter;
|
|
- a figure when pattern, distribution, relationship, sequence, or spatial information
|
|
matters.
|
|
|
|
Avoid duplicating the same information in prose, a table, and a figure. There is no
|
|
universal minimum, maximum, or display-per-word rule.
|
|
|
|
## Tables
|
|
|
|
Check:
|
|
|
|
- title and notes define population, time point, analysis set, units, and abbreviations;
|
|
- rows and columns preserve denominators and distinguish missing from zero;
|
|
- percentages can be recomputed from the recorded numerator and denominator;
|
|
- precision is consistent with the measurement and analysis;
|
|
- uncertainty and statistical quantities are named, not implied by symbols alone;
|
|
- values match the abstract, prose, figures, supplements, and consistency registry;
|
|
- cells remain accessible as text rather than an image when the venue allows.
|
|
|
|
## Figures
|
|
|
|
Check:
|
|
|
|
- axes, scales, transformations, units, and reference lines are explicit;
|
|
- truncated or nonlinear scales are visible and justified;
|
|
- individual observations or distributions are shown when scientifically appropriate;
|
|
- uncertainty is defined;
|
|
- group sizes and exclusions are available;
|
|
- legends identify all encodings;
|
|
- colors, shapes, line styles, labels, or patterns provide redundant cues;
|
|
- image panels include scale and orientation information where relevant;
|
|
- the final exported file matches current journal format and size instructions.
|
|
|
|
Do not add significance stars or trend lines unless they map to a verified analysis.
|
|
|
|
## Captions and alt text
|
|
|
|
A caption should state what is shown, define panels and encodings, identify the analysis
|
|
population, units, uncertainty, and relevant methods, and link to evidence IDs during
|
|
drafting.
|
|
|
|
Alt text should:
|
|
|
|
- identify the display type and purpose;
|
|
- summarize the principal visible pattern without adding a new conclusion;
|
|
- describe axes, groups, direction, and uncertainty needed to understand the display;
|
|
- avoid repeating the full caption or listing every data point;
|
|
- be reviewed manually with the final display.
|
|
|
|
Automated accessibility checks do not verify scientific correctness. Inspect contrast,
|
|
color independence, reading order, label size, keyboard or screen-reader behavior where
|
|
applicable, and legibility at final size.
|
|
|
|
## Flow diagrams
|
|
|
|
Use the current official flow-diagram resource for the selected guideline, such as
|
|
CONSORT 2025 or PRISMA 2020 [SW-S07, SW-S10]. Populate it only from verified counts.
|
|
Reconcile every branch and denominator with the methods, results, and registry.
|
|
|
|
## Final manual review
|
|
|
|
An accountable human should compare each display against source data and analysis
|
|
output, inspect permissions and confidentiality, verify captions and alt text, and
|
|
confirm the rendered export. Passing a file-format or consistency check does not certify
|
|
the display.
|